201 research outputs found

    Appropriateness of the anxiety subscale of the Hospital Anxiety and Depression Scale for Koreans to measure preoperative anxiety and the effect of preoperative anxiety on postoperative quality of recovery

    Get PDF
    Background The reliability and validity of the anxiety subscale of the Hospital Anxiety and Depression Scale for Koreans (K-HADS-A) has not been studied in Korean surgical patients. This study aimed to validate the usefulness of K-HADS-A for measuring preoperative anxiety in Korean surgical patients. Additionally, the effect of preoperative anxiety on postoperative quality of recovery was evaluated. Methods Preoperative anxiety in 126 inpatients with planned elective surgery was measured using the K-HADS-A. The postoperative quality of recovery was measured using the Korean version of the Quality of Recovery-15. The validity and reliability of the K-HADS-A were evaluated. The differences in quality of recovery on the first and seventh day postoperatively were then compared between the anxious and non-anxious groups. Results There was a statistical correlation between the K-HADS-A and Anxiety Likert Scale. The goodness-of-fit indices of the structural equation model showed how well the data from the K-HADS-A match their concept. The Kaiser-Meyer-Olkin value was 0.848, and the P value of Bartlett’s test of sphericity was < 0.001. Cronbach’s alpha was high at 0.872. The K-HADS-A had an acceptable level of validity and reliability. Postoperative quality of recovery was significantly lower in the anxious group (postoperative day 1: t = 2.058, P = 0.042; postoperative day 7: t = 3.430, P = 0.002). Conclusions The K-HADS-A is an acceptable tool for appropriately assessing preoperative anxiety in Korean surgical patients. Assessing preoperative anxiety is valuable, because preoperative anxiety affects the postoperative quality of mental and physical recovery

    Privacy-Preserving Machine Learning with Fully Homomorphic Encryption for Deep Neural Network

    Get PDF
    Fully homomorphic encryption (FHE) is one of the prospective tools for privacypreserving machine learning (PPML), and several PPML models have been proposed based on various FHE schemes and approaches. Although the FHE schemes are known as suitable tools to implement PPML models, previous PPML models on FHE encrypted data are limited to only simple and non-standard types of machine learning models. These non-standard machine learning models are not proven efficient and accurate with more practical and advanced datasets. Previous PPML schemes replace non-arithmetic activation functions with simple arithmetic functions instead of adopting approximation methods and do not use bootstrapping, which enables continuous homomorphic evaluations. Thus, they could not use standard activation functions and could not employ a large number of layers. The maximum classification accuracy of the existing PPML model with the FHE for the CIFAR-10 dataset was only 77% until now. In this work, we firstly implement the standard ResNet-20 model with the RNS-CKKS FHE with bootstrapping and verify the implemented model with the CIFAR-10 dataset and the plaintext model parameters. Instead of replacing the non-arithmetic functions with the simple arithmetic function, we use state-of-the-art approximation methods to evaluate these non-arithmetic functions, such as the ReLU, with sufficient precision [1]. Further, for the first time, we use the bootstrapping technique of the RNS-CKKS scheme in the proposed model, which enables us to evaluate a deep learning model on the encrypted data. We numerically verify that the proposed model with the CIFAR-10 dataset shows 98.67% identical results to the original ResNet-20 model with non-encrypted data. The classification accuracy of the proposed model is 90.67%, which is pretty close to that of the original ResNet-20 CNN model...Comment: 12 pages, 4 figure

    Bleeding complications associated with the molecular adsorbent recirculating system: a retrospective study

    Get PDF
    Background The molecular adsorbent recirculating system (MARS) is a hepatic replacement system that supports excretory liver function in patients with liver failure. However, since MARS has been employed in our hospital, bleeding complications have occurred in many patients during or after MARS. The objective of this study was to determine how MARS affects coagulopathy and identify specific factors associated with bleeding complications. Methods We retrospectively analyzed data from 17 patients undergoing a total of 41 MARS sessions. Complete blood count, coagulation profiles, and blood chemistry values were compared before and after MARS. To identify pre-MARS factors associated with increased bleeding after MARS, we divided patients into bleeder and non-bleeder groups and compared their pre-MARS laboratory values. Results MARS significantly reduced bilirubin and creatinine levels. MARS also increased prothrombin time and reduced platelet and fibrinogen, thus negatively impacting coagulation. Pre-MARS hemoglobin was significantly lower in the bleeder group than in the non-bleeder group (P=0.015). When comparing the upper and lower 33% of MARS sessions based on the hemoglobin reduction rate, hemoglobin reduction was significantly greater in MARS sessions involving patients with low pre-MARS international normalized ratio of prothrombin time (PT-INR) and factor V (P=0.038 and P=0.023, respectively). Conclusions MARS could appears to alter coagulation-related factors such as factor V and increase the risk of bleeding complications particularly in patient with low hemoglobin. However, individual differences among patients were large, and various factors, such as low hemoglobin, PT-INR, and factor V levels, appear to be involved

    Comparison of the Efficacy of Glimepiride, Metformin, and Rosiglitazone Monotherapy in Korean Drug-Naïve Type 2 Diabetic Patients: The Practical Evidence of Antidiabetic Monotherapy Study

    Get PDF
    BackgroundAlthough many anti-diabetic drugs have been used to control hyperglycemia for decades, the efficacy of commonly-used oral glucose-lowering agents in Korean type 2 diabetic patients has yet to be clearly demonstrated.MethodsWe evaluated the efficacy of glimepiride, metformin, and rosiglitazone as initial treatment for drug-naïve type 2 diabetes mellitus patients in a 48-week, double-blind, randomized controlled study that included 349 Korean patients. Our primary goal was to determine the change in HbA1c levels from baseline to end point. Our secondary goal was to evaluate changes in fasting plasma glucose (FPG) levels, body weight, frequency of adverse events, and the proportion of participants achieving target HbA1c levels.ResultsHbA1c levels decreased from 7.8% to 6.9% in the glimepiride group (P<0.001), from 7.9% to 7.0% in the metformin group (P<0.001), and from 7.8% to 7.0% (P<0.001) in the rosiglitazone group. Glimepiride and rosiglitazone significantly increased body weight and metformin reduced body weight during the study period. Symptomatic hypoglycemia was more frequent in the glimepiride group and diarrhea was more frequent in the metformin group.ConclusionThe efficacy of glimepiride, metformin, and rosiglitazone as antidiabetic monotherapies in drug-naïve Korean type 2 diabetic patients was similar in the three groups, with no statistical difference. This study is the first randomized controlled trial to evaluate the efficacy of commonly-used oral hypoglycemic agents in Korean type 2 diabetic patients. An additional subgroup analysis is recommended to obtain more detailed information

    Effect of pioglitazone on serum concentrations of osteoprotegerin in patients with type 2 diabetes mellitus

    Get PDF
    OBJECTIVE: Osteoprotegerin (OPG) acts as an important regulatory molecule in atherosclerosis. Recent studies report that thiazolidinediones could affect OPG expression. We investigated the relationship between OPG and inflammatory cytokines and the effects of pioglitazone (a PPARγ (PPARG) agonist) versus metformin on serum OPG levels in type 2 diabetic patients. DESIGN AND METHODS: Sixty-seven type 2 diabetic patients were included in this study. They were assigned to pioglitazone (15 mg/day, n=34) or metformin (1000 mg/day, n=33) during 24 weeks. Various anthropometric and metabolic parameters, OPG, interleukin 6 (IL6), C-reactive protein (CRP), adiponectin, and homeostasis model assessment of insulin resistance (HOMA-IR), were measured at baseline and at 6 months of treatment. RESULTS: Serum OPG levels correlated significantly with fasting plasma glucose (FPG), HbAlc, HOMA-IR, IL6, and CRP, and inversely correlated with adiponectin after adjusting for age (P<0.05). Multiple regression analysis showed that FPG, HbAlc, and adioponectin were independently correlated with OPG level. After 6 months of treatment, the reduction in FPG and HbAlc levels was similar between the two groups. Pioglitazone treatment significantly increased body mass index (P<0.05) and waist circumference (P<0.05) and decreased triglycerides (P<0.05) and HOMA-IR (P<0.01). The adiponectin concentration was increased (P<0.05), and OPG and CRP levels were decreased in the pioglitazone group (P<0.05), but were unchanged in the metformin group. The changes in serum OPG in the pioglitazone group showed significant correlation with changes in FPG, HbAlc, and adiponectin. CONCLUSIONS: In type 2 diabetic patients, pioglitazone decreases OPG levels, and this decrease in OPG levels might be associated with the increase in adiponectin.ope

    Multiple Endocrine Neoplasia Type 1 with Multiple Leiomyomas Linked to a Novel Mutation in the MEN1 Gene

    Get PDF
    Multiple endocrine neoplasia type 1 (MEN1) is an autosomal dominantly inherited syndrome. MEN1 is characterized by the presence of functioning and nonfunctioning tumors or hyperplasia of the pituitary gland, parathyroid glands, and pancreatic islet cells. In addition, MEN1 carriers can have adrenal or thyroid tumors and non-endocrine tumors, such as lipomas, angiofibromas, and leiomyomas. Although leiomyoma is not a major component of MEN1, it is thought to occur more frequently than expected. However, there has been no report of a case of MEN1 with leiomyoma in Korea so far. This report describes a patient with multiple leiomyomas in MEN1. A 50-year-old woman was referred for further evaluation of elevated calcium levels and osteoporosis. Biochemical abnormalities included hypercalcemia with elevated parathyroid hormone. There was hyperprolactinemia with pituitary microadenoma in sella MRI. An abdominal MRI demonstrated adrenal nodules and leiomyomas in the bladder and uterus. Endoscopic ultrasonography demonstrated esophageal leiomyoma and pancreatic islet cell tumor. A subtotal parathyroidectomy with thymectomy was performed. Sequencing of the MEN1 gene in this patient revealed a novel missense mutation (D350V, exon 7). This is the first case of MEN1 accompanied with multiple leiomyomas, parathyroid adenoma, pituitary adenoma, pancreatic tumor, and adrenal tumor

    Readout of a quantum processor with high dynamic range Josephson parametric amplifiers

    Full text link
    We demonstrate a high dynamic range Josephson parametric amplifier (JPA) in which the active nonlinear element is implemented using an array of rf-SQUIDs. The device is matched to the 50 Ω\Omega environment with a Klopfenstein-taper impedance transformer and achieves a bandwidth of 250-300 MHz, with input saturation powers up to -95 dBm at 20 dB gain. A 54-qubit Sycamore processor was used to benchmark these devices, providing a calibration for readout power, an estimate of amplifier added noise, and a platform for comparison against standard impedance matched parametric amplifiers with a single dc-SQUID. We find that the high power rf-SQUID array design has no adverse effect on system noise, readout fidelity, or qubit dephasing, and we estimate an upper bound on amplifier added noise at 1.6 times the quantum limit. Lastly, amplifiers with this design show no degradation in readout fidelity due to gain compression, which can occur in multi-tone multiplexed readout with traditional JPAs.Comment: 9 pages, 8 figure

    Measurement-Induced State Transitions in a Superconducting Qubit: Within the Rotating Wave Approximation

    Full text link
    Superconducting qubits typically use a dispersive readout scheme, where a resonator is coupled to a qubit such that its frequency is qubit-state dependent. Measurement is performed by driving the resonator, where the transmitted resonator field yields information about the resonator frequency and thus the qubit state. Ideally, we could use arbitrarily strong resonator drives to achieve a target signal-to-noise ratio in the shortest possible time. However, experiments have shown that when the average resonator photon number exceeds a certain threshold, the qubit is excited out of its computational subspace, which we refer to as a measurement-induced state transition. These transitions degrade readout fidelity, and constitute leakage which precludes further operation of the qubit in, for example, error correction. Here we study these transitions using a transmon qubit by experimentally measuring their dependence on qubit frequency, average photon number, and qubit state, in the regime where the resonator frequency is lower than the qubit frequency. We observe signatures of resonant transitions between levels in the coupled qubit-resonator system that exhibit noisy behavior when measured repeatedly in time. We provide a semi-classical model of these transitions based on the rotating wave approximation and use it to predict the onset of state transitions in our experiments. Our results suggest the transmon is excited to levels near the top of its cosine potential following a state transition, where the charge dispersion of higher transmon levels explains the observed noisy behavior of state transitions. Moreover, occupation in these higher energy levels poses a major challenge for fast qubit reset

    Overcoming leakage in scalable quantum error correction

    Full text link
    Leakage of quantum information out of computational states into higher energy states represents a major challenge in the pursuit of quantum error correction (QEC). In a QEC circuit, leakage builds over time and spreads through multi-qubit interactions. This leads to correlated errors that degrade the exponential suppression of logical error with scale, challenging the feasibility of QEC as a path towards fault-tolerant quantum computation. Here, we demonstrate the execution of a distance-3 surface code and distance-21 bit-flip code on a Sycamore quantum processor where leakage is removed from all qubits in each cycle. This shortens the lifetime of leakage and curtails its ability to spread and induce correlated errors. We report a ten-fold reduction in steady-state leakage population on the data qubits encoding the logical state and an average leakage population of less than 1×1031 \times 10^{-3} throughout the entire device. The leakage removal process itself efficiently returns leakage population back to the computational basis, and adding it to a code circuit prevents leakage from inducing correlated error across cycles, restoring a fundamental assumption of QEC. With this demonstration that leakage can be contained, we resolve a key challenge for practical QEC at scale.Comment: Main text: 7 pages, 5 figure
    corecore