41 research outputs found

    Intracranial carotid calcification on cranial computed tomography: visual scoring methods, semiautomated scores, and volume measurements in patients with stroke

    Get PDF
    Intracranial internal carotid artery calcification is associated with cerebrovascular risk factors and stroke, but few quantification methods are available. We tested the reliability of visual scoring, semiautomated Agatston score, and calcium volume measurement in patients with recent stroke. METHODS—: We used scans from a prospective hospital stroke registry and included patients with anterior circulation ischemic stroke or transient ischemic stroke whose noncontrast cranial computed tomographic scans were available electronically. Two raters measured semiautomatic quantitative Agatston score, and calcium volume, and performed qualitative visual scoring using the original 4-point Woodcock score and a modified Woodcock score, where each image on which the internal carotid arteries appeared was scored and the slice scores summed. RESULTS—: Intra- and interobserver coefficient of variations were 8.8% and 16.5% for Agatston, 8.8% and 15.5% for calcium volume, and 5.7% and 5.4% for the modified Woodcock visual score, respectively. The modified Woodcock visual score correlated strongly with both Agatston and calcium volume quantitative measures (both R(2)=0.84; P<0.0001); calcium volume increased by 0.47-mm/point increase in modified Woodcock visual score. Intracranial internal carotid artery calcification increased with age by all measures (eg, visual score, Spearman ρ=0.4; P=0.005). CONCLUSIONS—: Visual scores correlate highly with quantitative intracranial internal carotid artery calcification measures, with excellent observer agreements. Visual intracranial internal carotid artery scores could be a rapid and practical method for epidemiological studies

    Gastroesophageal reflux disease in 2006: The imperfect diagnosis

    Get PDF
    There continues to be significant controversy related to diagnostic testing for gastroesophageal reflux disease (GERD). Clearly, barium contrast fluoroscopy is superior to any other test in defining the anatomy of the upper gastrointestinal (UGI) tract. Although fluoroscopy can demonstrate gastroesophageal reflux (GER), this observation does not equate to GERD. Fluoroscopy time should not be prolonged to attempt to demonstrate GER during barium contrast radiography. There are no data to justify prolonging fluoroscopy time to perform provocative maneuvers to demonstrate reflux during barium contrast UGI series. Symptoms of GERD may be associated with physiologic esophageal acid exposure measured by intraesophageal pH monitoring, and a significant percentage of patients with abnormal esophageal acid exposure have no or minimal clinical symptoms of reflux. Abnormal acid exposure defined by pH monitoring over a 24-h period does not equate to GERD. In clinical practice presumptive diagnosis of GERD is reasonably assumed by substantial reduction or elimination of suspected reflux symptoms during therapeutic trial of acid reduction therapy

    The UV-SCOPE mission: ultraviolet spectroscopic characterization of planets and their environments

    Get PDF
    UV-SCOPE is a mission concept to determine the causes of atmospheric mass loss in exoplanets, investigate the mechanisms driving aerosol formation in hot Jupiters, and study the influence of the stellar environment on atmospheric evolution and habitability. As part of these investigations, the mission will generate a broad-purpose legacy database of time-domain ultraviolet (UV) spectra for nearly 200 stars and planets. The observatory consists of a 60 cm, f/10 telescope paired to a long-slit spectrograph, yielding simultaneous, almost continuous coverage between 1203 Å and 4000 Å, with resolutions ranging from 6000 to 240. The efficient instrument provides throughputs < 4% (far-UV; FUV) and < 15% (near-UV; NUV), comparable to HST/COS and much better than HST/STIS, over the same spectral range. A key design feature is the LiF prism, which serves as a dispersive element and provides high throughput even after accounting for radiation degradation. The use of two delta-doped Electron-Multiplying CCD detectors with UV-optimized, single-layer anti-reflection coatings provides high quantum efficiency and low detector noise. From the Earth-Sun second Lagrangian point, UV-SCOPE will continuously observe planetary transits and stellar variability in the full FUV-to-NUV range, with negligible astrophysical background. All these features make UV-SCOPE the ideal instrument to study exoplanetary atmospheres and the impact of host stars on their planets. UV-SCOPE was proposed to NASA as a Medium Explorer (MidEx) mission for the 2021 Announcement of Opportunity. If approved, the observatory will be developed over a 5-year period. Its primary science mission takes 34 months to complete. The spacecraft carries enough fuel for 6 years of operations

    Genome-Wide Association Study in East Asians Identifies Novel Susceptibility Loci for Breast Cancer

    Get PDF
    Genetic factors play an important role in the etiology of both sporadic and familial breast cancer. We aimed to discover novel genetic susceptibility loci for breast cancer. We conducted a four-stage genome-wide association study (GWAS) in 19,091 cases and 20,606 controls of East-Asian descent including Chinese, Korean, and Japanese women. After analyzing 690,947 SNPs in 2,918 cases and 2,324 controls, we evaluated 5,365 SNPs for replication in 3,972 cases and 3,852 controls. Ninety-four SNPs were further evaluated in 5,203 cases and 5,138 controls, and finally the top 22 SNPs were investigated in up to 17,423 additional subjects (7,489 cases and 9,934 controls). SNP rs9485372, near the TGF-β activated kinase (TAB2) gene in chromosome 6q25.1, showed a consistent association with breast cancer risk across all four stages, with a P-value of 3.8×10−12 in the combined analysis of all samples. Adjusted odds ratios (95% confidence intervals) were 0.89 (0.85–0.94) and 0.80 (0.75–0.86) for the A/G and A/A genotypes, respectively, compared with the genotype G/G. SNP rs9383951 (P = 1.9×10−6 from the combined analysis of all samples), located in intron 5 of the ESR1 gene, and SNP rs7107217 (P = 4.6×10−7), located at 11q24.3, also showed a consistent association in each of the four stages. This study provides strong evidence for a novel breast cancer susceptibility locus represented by rs9485372, near the TAB2 gene (6q25.1), and identifies two possible susceptibility loci located in the ESR1 gene and 11q24.3, respectively

    Equivalence of measurements of carotid stenosis. A comparison of three methods on 1001 angiograms. European Carotid Surgery Trialists' Collaborative Group.

    No full text
    BACKGROUND AND PURPOSE: There is confusion about how carotid stenosis should be measured on angiograms. If the results of research based on different methods of measurement of stenosis are to be discussed and the results of clinical trials properly applied to routine clinical practice, measurements made by the different methods must be formally compared. METHODS: The method of measurement of stenosis used in the European Carotid Surgery Trial (ECST), that used in the North American Symptomatic Carotid Endarterectomy Trial (NASCET), and a method based on measurement of the common carotid (CC) artery lumen diameter were compared. Carotid stenosis was measured by two observers, working independently and using the three different methods of measurement, on the angiographic view of the symptomatic carotid stenosis that showed the most severe disease in 1001 patients from the ECST. RESULTS: The results of using the ECST and CC methods differed from those of using the NASCET method in the classification of stenoses as mild (0% to 29%), moderate (30% to 69%), or severe (70% to 99%) in 51% of measurements. The ECST and CC methods indicated that twice as many stenoses were severe as did the NASCET method, and classified less than a third of the number of stenoses as mild. The results of the ECST and CC methods differed from each other in 15% of measurements. The relations between measurements made by each method to those made by the others were approximately linear, so a simple equation could be derived to convert measurements made by one method to measurements made by the others. CONCLUSIONS: There were major and clinically important disparities between measurements of stenosis made using different methods of measurement on the same angiograms. However, it is possible to convert measurements made by one method to those of another using a simple arithmetic equation

    The effect of angiographic technique and image quality on the reproducibility of measurement of carotid stenosis and assessment of plaque surface morphology.

    No full text
    We studied the reproducibility of measurement of carotid stenosis and assessment of plaque surface morphology on 1001 angiograms from a consecutive series of patients entered into the European Carotid Surgery Trial. Inter-observer agreement (Kappa statistic, 95% confidence interval (CI)) for categorization of carotid stenosis, as 0-29%, 30-69% or 70-99% was good (0.68, 0.63-0.73) on 789 conventional or digitally subtracted selective angiograms, and good (0.64, 0.54-0.75) on 174 conventionally and digitally subtracted aortic arch injection angiograms, but was poor (0.29, 0.02-0.80) on 29 intravenous digital subtraction angiograms. Inter-observer agreement did not vary with the method of image acquisition of arterial angiograms, but was dependent on the quality of visualization of the stenosis: kappa = 0.73 (0.67-0.79) for good quality angiograms vs. 0.54 (0.44-0.64) for poor quality angiograms. Inter-observer agreement for assessment of plaque surface morphology was moderate (kappa 0.4-0.6) and did not vary with type of angiography or method of image acquisition. However, ulceration was reported most frequently on selective angiograms and on those angiograms on which the quality of visualization of the stenosis was good. We conclude that the reproducibility of measurement of carotid stenosis and the assessment of plaque surface morphology vary depending on the type of angiography and the quality of visualization of the stenosis. This should be taken into account when validating non-invasive methods of imaging the carotid bifurcation
    corecore