    Experimental and Analytical Investigation Based on 1/2 Scale Model for a Cleanroom Unit Module Consisting of Steel Section and Reinforced Concrete

    Get PDF
    The rapid advances in high tech industries and the increased demand for high precision and reliability of their production environments call for larger structures and higher vertical vibration performance for high technology facilities. Therefore, there is an urgent demand for structural design and vertical vibration evaluation technologies for high tech facility structures. For estimating the microvibration performance for a cleanroom unit module in high technology facilities, this study performs the scale modeling experiment and analytical validation. First, the 1/2 scale model (width 7500 mm, depth 7500 mm, and height 7250 mm) for a cleanroom unit module is manufactured based on a mass-based similitude law which does not require additional mass. The dynamic test using an impact hammer is conducted to obtain the transfer function of 1/2 scale model. The transfer function derived from the test is compared with the analytical results to calibrate the analytical model. It is found that, unlike for static analyses, the stiffness of embedded reinforcement must be considered for estimating microvibration responses. Finally, the similitude law used in this study is validated by comparing the full-scale analytical model and 1/2 scale analytical model for a cleanroom unit module

    Performance-Based Multiobjective Optimal Seismic Retrofit Method for a Steel Moment-Resisting Frame Considering the Life-Cycle Cost

    Get PDF
    This study proposes a performance-based multiobjective optimization seismic retrofit method for steel moment-resisting frames. The brittle joints of pre-Northridge steel moment-resisting frames are retrofitted to achieve ductility; the method involves determining the position and number of connections to be retrofitted. The optimal solution is determined by applying the nondominated sorting genetic algorithm-II (NSGA-II), which acts as a multiobjective seismic retrofit optimization technique. As objective functions, the initial cost for the connection retrofit and lifetime seismic damage cost were selected, and a seismic performance level below the 5% interstory drift ratio was employed as a constraint condition. The proposed method was applied to the SAC benchmark three- and nine-story buildings, and several Pareto solutions were obtained. The optimized retrofit solutions indicated that the lifetime seismic damage cost decreased as the initial retrofit cost increased. Although every Pareto solution existed within a seismic performance boundary set by a constraint function, the seismic performance tended to increase with the initial retrofit cost. Analysis and economic assessment of the relations among the initial retrofit cost, lifetime seismic damage cost, total cost, and seismic performance of the derived Pareto solution allow building owners to make seismic retrofit decisions more rationally

    Analytical models for estimation of the maximum strain of beam structures based on optical fiber Bragg grating sensors

    Get PDF
    The structural safety of a beam structure is assessed by a comparison between the maximum stress measured during monitoring and the allowable stress of the beam. However, the strain directly measured from a fiber Bragg grat- ing (FBG) strain sensor may not be identical with the actual maximum strain induced in the structural member. Unless a FBG strain sensor is installed exactly on where maximum strain occurs, the reliability of the evaluated safety based on the measured strain depends on the number and location of sensors. Therefore, in this paper, analytical models are presented for estimation of the maximum values of strains in a linear elastic beam using the local strains measured from FBG sensors. The model is tested in an experiment by comparing estimated maximum strain from FBG sensors and directly measured strain from electrical gages. For the assessment of safety of typical beam structures in buildings and infrastructures, analytical models for various loading and boundary conditions are provided

    Wind-induced response control model for high-rise buildings based on resizing method

    Get PDF
    A variety of methods have been applied to reduce the effect of the wind-induced vibration of a high-rise building as the excessive wind-induced vibration at the top of a high-rise building can cause physical and psychological discomfort to the user or the residents. For structural engineers, the most effective approach to control the wind-induced responses of high-rise buildings would be to control the stiffness or natural frequency of the building. This paper presents a practical design model to control the wind-induced responses of a high-rise building. In the model, the stiffness of a high-rise building is maximized to increase the natural frequency of the building by the resizing algorithm. The proposed design model is applied to control the wind-induced vibration of an actual 37-storey building during the initial stage of its structural design
    • …