139 research outputs found

    Unilateral thoracoscopic surgical approach for diffuse emphysema

    Get PDF
    AbstractWe evaluated the use of a lateral thoracoscopic approach for lung reduction surgery in patients with diffuse emphysema. Sixty-seven patients with a mean age of 61.9 years underwent operation. Operative side was determined by preoperative imaging. The procedures were laser ablation in 10 patients and stapler resection in 57 patients. Ten patients, including six of the 10 patients in the laser-only group had poor outcome (death or hospitalization longer than 30 days), leading us to abandon the laser technique. Of the remaining 57 patients undergoing primary stapled resection, duration of chest tube placement averaged 13 days (range 3 to 53 days) with a mean hospital stay of 17 days (range 6 to 99 days). Seven patients required ventilation for longer than 72 hours, six patients underwent conversion of the procedure to open thoracotomy, four patients acquired arrhythmias, and three patients were treated for empyema. There was one early death (1.7%), from cardiopulmonary failure. Forty patients returned for 3-month evaluation. Significant ( p < 0.0001) improvements were seen in forced vital capacity (2.69 L after vs 2.26 L before) and forced expiration volume in 1 second (1.04 L after vs 0.82 L before), with 25 of 40 patients (63%) showing an improvement of more than 20%. Lung volume measures, in particular residual volume, fell significantly. Arterial blood gas analysis revealed that carbon dioxide tension fell significantly in patients with preoperative hypercapnia (carbon dioxide tension >45 mm Hg, p = 0.018). Six-minute walk test results improved (894 feet after vs 784 feet before, p = 0.002), and symptomatic benefit was confirmed by significant improvement in the dyspnea index. The combination of both hypercapnia and reduced single-breath diffusing capacity for carbon monoxide was significantly more frequent ( p = 0.0026) and was 86% specific (5 of 6 patients) in predicting serious postoperative risk. We conclude that the lateral thoracoscopic surgical approach to diffuse emphysema offers significant improvement in pulmonary mechanics and functional impairment. Patients with a combination of hypercapnia and reduced single-breath diffusing capacity for carbon monoxide should not be considered for this procedure because of significant perioperative risk. (J THORAC CARDIOVASC SURG 1996;111:308-16

    Bronchoscopic Lung Volume Reduction Coil Treatment for Severe Emphysema:A Systematic Review and Meta-Analysis of Individual Participant Data

    Get PDF
    BACKGROUND: Lung volume reduction coil (LVR-coil) treatment provides a minimally invasive treatment option for severe emphysema patients which has been studied in multiple clinical trials. OBJECTIVES: The aim of the study was to assess the effect of LVR-coil treatment on pulmonary function, quality of life, and exercise capacity using individual participant data. METHOD: PubMed, Web of Science, and EMBASE were searched until May 17, 2021. Prospective single-arm and randomized controlled trials that evaluated the effect of LVR-coil treatment on forced expiratory volume in 1 s (FEV1), residual volume (RV), St. George Respiratory Questionnaire (SGRQ) total score, and/or 6-min walk distance (6MWD) and were registered in an official clinical trial database were eligible for inclusion. Individual patient data were requested, and a linear mixed effects model was used to calculate overall treatment effects. RESULTS: Eight trials were included in the final analysis, representing 680 individual patients. LVR-coil treatment resulted in a significant improvement in FEV1 at 3- (0.09 L [95% confidence interval (95% CI): 0.06-0.12]) and 6-month follow-up (0.07 L [95% CI: 0.03-0.10]), a significant reduction in RV at 3- (-0.45L [95% CI: -0.62 to -0.28]), 6- (-0.33L [95% CI: -0.52 to -0.14]), and 12-month follow-up (-0.36L [95% CI: -0.64 to -0.08]), a significant reduction in SGRQ total score at 3- (-12.3 points [95% CI: -15.8 to -8.8]), 6- (-10.1 points [95% CI: -12.8 to -7.3]), and 12-month follow-up (-9.8 points [95% CI: -15.0 to -4.7]) and a significant increase in 6MWD at 3-month follow-up (38 m [95% CI: 18-58]). CONCLUSIONS: LVR-coil treatment in emphysema patients results in sustained improvements in pulmonary function and quality of life and shorter lived improvements in exercise capacity. Since the owner of this LVR-coil has decided to stop the production and newer generations LVR-coils are currently being developed, these results can act as a reference for future studies and clinical guidance

    Predictive significance of the six-minute walk distance for long-term survival in chronic hypercapnic respiratory failure

    Get PDF
    Background: The 6-min walk distance ( 6-MWD) is a global marker of functional capacity and prognosis in chronic obstructive pulmonary disease ( COPD), but less explored in other chronic respiratory diseases. Objective: To study the role of 6-MWD in chronic hypercapnic respiratory failure ( CHRF). Methods: In 424 stable patients with CHRF and non-invasive ventilation ( NIV) comprising COPD ( n = 197), restrictive diseases ( RD; n = 112) and obesity-hypoventilation- syndrome ( OHS; n = 115), the prognostic value of 6-MWD for long- term survival was assessed in relation to that of body mass index (BMI), lung function, respiratory muscle function and laboratory parameters. Results: 6-MWD was reduced in patients with COPD ( median 280 m; quartiles 204/350 m) and RD ( 290 m; 204/362 m) compared to OHS ( 360 m; 275/440 m; p <0.001 each). Overall mortality during 24.9 (13.1/40.5) months was 22.9%. In the 424 patients with CHRF, 6-MWD independently predicted mortality in addition to BMI, leukocytes and forced expiratory volume in 1 s ( p <0.05 each). In COPD, 6-MWD was strongly associated with mortality using the median {[} p <0.001, hazard ratio ( HR) = 3.75, 95% confidence interval (CI): 2.24-6.38] or quartiles as cutoff levels. In contrast, 6-MWD was only significantly associated with impaired survival in RD patients when it was reduced to 204 m or less (1st quartile; p = 0.003, HR = 3.31, 95% CI: 1.73-14.10), while in OHS 6-MWD had not any prognostic value. Conclusions: In patients with CHRF and NIV, 6-MWD was predictive for long- term survival particularly in COPD. In RD only severely reduced 6-MWD predicted mortality, while in OHS 6-MWD was relatively high and had no prognostic value. These results support a disease-specific use of 6-MWD in the routine assessment of patients with CHRF. Copyright (C) 2007 S. Karger AG, Basel

    The HLA Class II Allele Allele DRB1*15 is over-represented in patients with Idiopathic Pulmonary Fibrosis

    Get PDF
    BACKGROUND: Idiopathic pulmonary fibrosis (IPF) is a progressive and medically refractory lung disease with a grim prognosis. Although the etiology of IPF remains perplexing, abnormal adaptive immune responses are evident in many afflicted patients. We hypothesized that perturbations of human leukocyte antigen (HLA) allele frequencies, which are often seen among patients with immunologic diseases, may also be present in IPF patients. METHODS/PRINCIPAL FINDINGS: HLA alleles were determined in subpopulations of IPF and normal subjects using molecular typing methods. HLA-DRB1*15 was over-represented in a discovery cohort of 79 Caucasian IPF subjects who had lung transplantations at the University of Pittsburgh (36.7%) compared to normal reference populations. These findings were prospectively replicated in a validation cohort of 196 additional IPF subjects from four other U.S. medical centers that included both ambulatory patients and lung transplantation recipients. High-resolution typing was used to further define specific HLA-DRB1*15 alleles. DRB1*1501 prevalence in IPF subjects was similar among the 143 ambulatory patients and 132 transplant recipients (31.5% and 34.8%, respectively, p = 0.55). The aggregate prevalence of DRB1*1501 in IPF patients was significantly greater than among 285 healthy controls (33.1% vs. 20.0%, respectively, OR 2.0; 95%CI 1.3-2.9, p = 0.0004). IPF patients with DRB1*1501 (n = 91) tended to have decreased diffusing capacities for carbon monoxide (DL(CO)) compared to the 184 disease subjects who lacked this allele (37.8±1.7% vs. 42.8±1.4%, p = 0.036). CONCLUSIONS/SIGNIFICANCE: DRB1*1501 is more prevalent among IPF patients than normal subjects, and may be associated with greater impairment of gas exchange. These data are novel evidence that immunogenetic processes can play a role in the susceptibility to and/or manifestations of IPF. Findings here of a disease association at the HLA-DR locus have broad pathogenic implications, illustrate a specific chromosomal area for incremental, targeted genomic study, and may identify a distinct clinical phenotype among patients with this enigmatic, morbid lung disease

    The HLA class II allele DRB1*1501 is over-represented in patients with idiopathic pulmonary fibrosis

    Get PDF
    Background: Idiopathic pulmonary fibrosis (IPF) is a progressive and medically refractory lung disease with a grim prognosis. Although the etiology of IPF remains perplexing, abnormal adaptive immune responses are evident in many afflicted patients. We hypothesized that perturbations of human leukocyte antigen (HLA) allele frequencies, which are often seen among patients with immunologic diseases, may also be present in IPF patients. Methods/Principal Findings: HLA alleles were determined in subpopulations of IPF and normal subjects using molecular typing methods. HLA-DRB1*15 was over-represented in a discovery cohort of 79 Caucasian IPF subjects who had lung transplantations at the University of Pittsburgh (36.7%) compared to normal reference populations. These findings were prospectively replicated in a validation cohort of 196 additional IPF subjects from four other U.S. medical centers that included both ambulatory patients and lung transplantation recipients. High-resolution typing was used to further define specific HLA-DRB1*15 alleles. DRB1*1501 prevalence in IPF subjects was similar among the 143 ambulatory patients and 132 transplant recipients (31.5% and 34.8%, respectively, p = 0.55). The aggregate prevalence of DRB1*1501 in IPF patients was significantly greater than among 285 healthy controls (33.1% vs. 20.0%, respectively, OR 2.0; 95%CI 1.3-2.9, p = 0.0004). IPF patients with DRB1*1501 (n = 91) tended to have decreased diffusing capacities for carbon monoxide (DLCO) compared to the 184 disease subjects who lacked this allele (37.8±1.7% vs. 42.8±1.4%, p = 0.036). Conclusions/Significance: DRB1*1501 is more prevalent among IPF patients than normal subjects, and may be associated with greater impairment of gas exchange. These data are novel evidence that immunogenetic processes can play a role in the susceptibility to and/or manifestations of IPF. Findings here of a disease association at the HLA-DR locus have broad pathogenic implications, illustrate a specific chromosomal area for incremental, targeted genomic study, and may identify a distinct clinical phenotype among patients with this enigmatic, morbid lung disease

    Paired inspiratory-expiratory chest CT scans to assess for small airways disease in COPD

    Full text link
    Abstract Background Gas trapping quantified on chest CT scans has been proposed as a surrogate for small airway disease in COPD. We sought to determine if measurements using paired inspiratory and expiratory CT scans may be better able to separate gas trapping due to emphysema from gas trapping due to small airway disease. Methods Smokers with and without COPD from the COPDGene Study underwent inspiratory and expiratory chest CT scans. Emphysema was quantified by the percent of lung with attenuation < −950HU on inspiratory CT. Four gas trapping measures were defined: (1) Exp−856, the percent of lung < −856HU on expiratory imaging; (2) E/I MLA, the ratio of expiratory to inspiratory mean lung attenuation; (3) RVC856-950, the difference between expiratory and inspiratory lung volumes with attenuation between −856 and −950 HU; and (4) Residuals from the regression of Exp−856 on percent emphysema. Results In 8517 subjects with complete data, Exp−856 was highly correlated with emphysema. The measures based on paired inspiratory and expiratory CT scans were less strongly correlated with emphysema. Exp−856, E/I MLA and RVC856-950 were predictive of spirometry, exercise capacity and quality of life in all subjects and in subjects without emphysema. In subjects with severe emphysema, E/I MLA and RVC856-950 showed the highest correlations with clinical variables. Conclusions Quantitative measures based on paired inspiratory and expiratory chest CT scans can be used as markers of small airway disease in smokers with and without COPD, but this will require that future studies acquire both inspiratory and expiratory CT scans.http://deepblue.lib.umich.edu/bitstream/2027.42/134586/1/12931_2012_Article_1346.pd

    Paired inspiratory-expiratory chest CT scans to assess for small airways disease in COPD

    Get PDF
    Background: Gas trapping quantified on chest CT scans has been proposed as a surrogate for small airway disease in COPD. We sought to determine if measurements using paired inspiratory and expiratory CT scans may be better able to separate gas trapping due to emphysema from gas trapping due to small airway disease. Methods: Smokers with and without COPD from the COPDGene Study underwent inspiratory and expiratory chest CT scans. Emphysema was quantified by the percent of lung with attenuation < −950HU on inspiratory CT. Four gas trapping measures were defined: (1) Exp−856, the percent of lung < −856HU on expiratory imaging; (2) E/I MLA, the ratio of expiratory to inspiratory mean lung attenuation; (3) RVC856-950, the difference between expiratory and inspiratory lung volumes with attenuation between −856 and −950 HU; and (4) Residuals from the regression of Exp−856 on percent emphysema. Results: In 8517 subjects with complete data, Exp−856 was highly correlated with emphysema. The measures based on paired inspiratory and expiratory CT scans were less strongly correlated with emphysema. Exp−856, E/I MLA and RVC856-950 were predictive of spirometry, exercise capacity and quality of life in all subjects and in subjects without emphysema. In subjects with severe emphysema, E/I MLA and RVC856-950 showed the highest correlations with clinical variables. Conclusions: Quantitative measures based on paired inspiratory and expiratory chest CT scans can be used as markers of small airway disease in smokers with and without COPD, but this will require that future studies acquire both inspiratory and expiratory CT scans

    Increased Matrix Metalloproteinase (MMPs) Levels Do Not Predict Disease Severity or Progression in Emphysema

    Get PDF
    Rationale: Though matrix metalloproteinases (MMPs) are critical in the pathogenesis of COPD, their utility as a disease biomarker remains uncertain. This study aimed to determine whether bronchoalveolar lavage (BALF) or plasma MMP measurements correlated with disease severity or functional decline in emphysema. Methods: Enzyme-linked immunosorbent assay and luminex assays measured MMP-1, -9, -12 and tissue inhibitor of matrix metalloproteinase-1 in the BALF and plasma of non-smokers, smokers with normal lung function and moderate-to-severe emphysema subjects. In the cohort of 101 emphysema subjects correlative analyses were done to determine if MMP or TIMP-1 levels were associated with key disease parameters or change in lung function over an 18-month time period. Main Results: Compared to non-smoking controls, MMP and TIMP-1 BALF levels were significantly elevated in the emphysema cohort. Though MMP-1 was elevated in both the normal smoker and emphysema groups, collagenase activity was only increased in the emphysema subjects. In contrast to BALF, plasma MMP-9 and TIMP-1 levels were actually decreased in the emphysema cohort compared to the control groups. Both in the BALF and plasma, MMP and TIMP-1 measurements in the emphysema subjects did not correlate with important disease parameters and were not predictive of subsequent functional decline. Conclusions: MMPs are altered in the BALF and plasma of emphysema; however, the changes in MMPs correlate poorly with parameters of disease intensity or progression. Though MMPs are pivotal in the pathogenesis of COPD, these findings suggest that measuring MMPs will have limited utility as a prognostic marker in this disease. © 2013 D'Armiento et al
    • …
    corecore