403 research outputs found

    Broadband mid-IR frequency comb with CSP and AGS from a Er,Tm:Ho fiber laser

    Get PDF
    We report on the generation of a 2500 nm bandwidth frequency comb at 6.5 μm central wavelength based on critically phase-matched parametric down-conversion in the nonlinear crystal CdSiP 2 CdSiP2 (CSP), driven by a compact Er,Tm:Ho fiber laser. The generated ultra-broadband pulses show a transform-limited duration of 2.3 optical cycles and carry up to 150 pJ of energy at a 100 MHz pulse repetition rate. For comparison, the spectrum generated in AgGaS 2 AgGaS2 (AGS) spans from 6.2 to 7.4 μm at full-width at half-maximum (FWHM) with a pulse energy of 3 pJ. A full 3D nonlinear wave propagation code is used for optimization of the noncollinear angle, propagation direction, and crystal thickness.Peer ReviewedPostprint (author's final draft

    High-power femtosecond mid-infrared optical parametric oscillator at 7  μm based on CdSiP2

    Get PDF
    We report a femtosecond optical parametric oscillator (OPO) for the mid-infrared (mid-IR), generating a record average power of 110 mW at 7 μm. The OPO, based on CdSiP2 (CSP) as the nonlinear crystal, provides idler wavelength tuning across 6540–7186 nm with spectral bandwidths >400  nm at −10  dB level over the entire range, and a maximum bandwidth of 478 nm at 6.9 μm. To the best of our knowledge, this is the highest average power generated from a femtosecond OPO in the deep mid-IR. The OPO also provides near-IR signal wavelengths tunable across 1204–1212 nm with a usable power of 450 mW in 418-fs pulses at 1207 nm. The simultaneously measured signal and idler power exhibit a passive stability better than 1.6% rms and 3% rms, respectively. A mid-IR idler spectral stability with a standard deviation of the frequency fluctuations better than 40 MHz over 15 min, limited by the measurement resolution, is realized. Using the mid-IR idler from the CSP OPO, we perform Fourier-transform spectroscopy to detect liquid phase organic solvent, toluene (C7H8), in the molecular fingerprint region.Postprint (author’s final draft

    Anticoagulation for the long-term treatment of venous thromboembolism in patients with cancer

    Get PDF
    Background: Cancer increases the risk of thromboembolic events in patients including those receiving anticoagulation treatments. Objectives: To compare the efficacy and safety of low molecular weight heparin (LMWH) and oral anticoagulants for the long-term treatment of venous thromboembolism (VTE) in patients with cancer. Search methods: We conducted a comprehensive search for studies of anticoagulation in cancer patients including 1. a February 2013 electronic search of: the Cochrane Central Register of Controlled Trials (CENTRAL Issue 12, 2012), MEDLINE, and EMBASE; 2. a handsearch of conference proceedings; 3. checking of references of included studies; 4. use of the 'related citation' feature in PubMed; and 5. a search of clinicaltrials.gov for ongoing studies. Selection criteria: We included randomized controlled trials (RCTs) comparing long-term treatment with LMWH versus oral anticoagulants (vitamin K antagonist (VKA) or ximelagatran) in patients with cancer and symptomatic objectively confirmed VTE. Data collection and analysis: Using a standardized data form, we extracted data on methodological quality, participants, interventions and outcomes of interest: survival, recurrent VTE, major bleeding, minor bleeding, thrombocytopenia, and postphlebitic syndrome. We assessed the quality of evidence at the outcome level following the GRADE approach. Main results: Of 9559 identified citations, 10 RCTs (11 reports) were eligible and reported data for 1981 patients with cancer. We excluded 14 studies in which patients with cancer constituted study subgroups, but did not report outcome data for them. Meta-analysis of seven RCTs comparing LMWH with VKA found no statistically significant survival benefit (hazard ratio (HR) 0.96; 95% confidence interval (CI) 0.81 to 1.14) but a statistically significant reduction in VTE (HR 0.47; 95% CI 0.32 to 0.71). The remaining findings did not exclude a beneficial or harmful effect of LMWH compared with VKA for the outcomes of major bleeding (RR 1.07; 95% CI 0.52 to 2.19), minor bleeding (RR 0.89; 95% CI 0.51 to 1.55), or thrombocytopenia (RR 0.98; 95% CI 0.57 to 1.66). We judged the quality of evidence as low for mortality, major bleeding, and minor bleeding, and as moderate for recurrent VTE. One RCT comparing dabigatran with VKA did not exclude beneficial or harmful effects of one agent over the other. One RCT comparing six months' extension of anticoagulation with 18 months of ximelagatran 24 \u3bcg twice daily versus no extended ximelagatran did not exclude beneficial or harmful effects for the outcomes of reduction in VTE, mortality, and minor bleeding. One RCT comparing once-weekly subcutaneous injection of idraparinux for three or six months versus standard treatment (parenteral anticoagulation followed by warfarin or acenocoumarol) suggested a reduction in recurrent VTE (HR 0.39; 95% CI 0.14 to 1.11) at six months, but did not exclude beneficial or harmful effects for the outcomes of mortality (HR 0.99; 95% CI 0.66 to 1.48) and major bleeding (RR 1.04; 95% CI 0.39 to 2.83). Authors' conclusions: For the long-term treatment of VTE in patients with cancer, LMWH compared with VKA reduces venous thromboembolic events but not mortality. The decision for a patient with cancer and VTE to start long-term LMWH versus oral anticoagulation should balance the benefits and harms and integrate the patient's values and preferences for the important outcomes and alternative management strategies

    GRADE equity guidelines 4: guidance on how to assess and address health equity within the evidence to decision process

    Get PDF
    Objective: The aim of this paper is to provide detailed guidance on how to incorporate health equity within the GRADE (Grading Recommendations Assessment and Development Evidence) evidence to decision process. Study design and setting: We developed this guidance based on the GRADE evidence to decision (EtD) framework, iteratively reviewing and modifying draft documents, in person discussion of project group members and input from other GRADE members. Results: Considering the impact on health equity may be required, both in general guidelines, and guidelines that focus on disadvantaged populations. We suggest two approaches to incorporate equity considerations: 1) assessing the potential impact of interventions on equity and; 2) incorporating equity considerations when judging or weighing each of the evidence to decision criteria. We provide guidance and include illustrative examples. Conclusion: Guideline panels should consider the impact of recommendations on health equity with attention to remote and underserviced settings and disadvantaged populations. Guideline panels may wish to incorporate equity judgments across the evidence to decision framework

    From the Trenches: A Cross-Sectional Study Applying the GRADE Tool in Systematic Reviews of Healthcare Interventions

    Get PDF
    Background: GRADE was developed to address shortcomings of tools to rate the quality of a body of evidence. While much has been published about GRADE, there are few empirical and systematic evaluations. Objective: To assess GRADE for systematic reviews (SRs) in terms of inter-rater agreement and identify areas of uncertainty. Design: Cross-sectional, descriptive study. Methods: We applied GRADE to three SRs (n = 48, 66, and 75 studies, respectively) with 29 comparisons and 12 outcomes overall. Two reviewers graded evidence independently for outcomes deemed clinically important a priori. Inter-rater reliability was assessed using kappas for four main domains (risk of bias, consistency, directness, and precision) and overall quality of evidence. Results: For the first review, reliability was: k = 0.41 for risk of bias; 0.84 consistency; 0.18 precision; and 0.44 overall quality. Kappa could not be calculated for directness as one rater assessed all items as direct; assessors agreed in 41 % of cases. For the second review reliability was: 0.37 consistency and 0.19 precision. Kappa could not be assessed for other items; assessors agreed in 33 % of cases for risk of bias; 100 % directness; and 58 % overall quality. For the third review, reliability was: 0.06 risk of bias; 0.79 consistency; 0.21 precision; and 0.18 overall quality. Assessors agreed in 100 % of cases for directness. Precision created the most uncertainty due to difficulties in identifying ‘‘optimal’ ’ information size and ‘‘clinica

    Combining scores from different patient reported outcome measures in meta-analyses: when is it justified?

    Get PDF
    BACKGROUND: Combining outcomes and the use of standardized effect measures such as effect size and standardized response mean across instruments allows more comprehensive meta-analyses and should avoid selection bias. However, such analysis ideally requires that the instruments correlate strongly and that the underlying assumption of similar responsiveness is fulfilled. The aim of the study was to assess the correlation between two widely used health-related quality of life instruments for patients with chronic obstructive pulmonary disease and to compare the instruments' responsiveness on a study level. METHODS: We systematically identified all longitudinal studies that used both the Chronic Respiratory Questionnaire (CRQ) and the St. George's Respiratory Questionnaire (SGRQ) through electronic searches of MEDLINE, EMBASE, CENTRAL and PubMed. We assessed the correlation between CRQ (scale 1 – 7) and SGRQ (scale 1 – 100) change scores and compared responsiveness of the two instruments by comparing standardized response means (change scores divided by their standard deviation). RESULTS: We identified 15 studies with 23 patient groups. CRQ change scores ranged from -0.19 to 1.87 (median 0.35, IQR 0.14–0.68) and from -16.00 to 3.00 (median -3.00, IQR -4.73–0.25) for SGRQ change scores. The correlation between CRQ and SGRQ change scores was 0.88. Standardized response means of the CRQ (median 0.51, IQR 0.19–0.98) were significantly higher (p < 0.001) than for the SGRQ (median 0.26, IQR -0.03–0.40). CONCLUSION: Investigators should be cautious about pooling the results from different instruments in meta-analysis even if they appear to measure similar constructs. Despite high correlation in changes scores, responsiveness of instruments may differ substantially and could lead to important between-study heterogeneity and biased meta-analyses
    corecore