2,450 research outputs found
Vacuum-polarization contribution to the hyperfine-structure splitting of hydrogenlike atoms
A calculation of the vacuum-polarization contribution to the hyperfine splitting for hydrogenlike atoms is presented. The extended nuclear charge distribution is taken into account. For the experimentally interesting case 209Bi82+ we predict a delta-lambda- -1.6 nm shift for the transition wavelength of the ground-state hyperfine splitting
Formation of heavy quarks in ultrarelativistic heavy-ion collisions
We investigate the production of heavy quarks in continuum and bound states in nuclear collisions. Creation rates for free bb and tt quark pairs and for bottomonium and toponium in the ground state are computed at energies of the BNL Relativistic Heavy Ion Collider, CERN Large Hadron Collider (LHC), and Superconducting Super Collider. Central and peripheral heavy-ion collisions are discussed. For top-quark creation we assumed a mass range of 90≤mt≤250 GeV. The creation rate for top quarks in peripheral collisions is estimated to be by a factor 40 to 130 smaller compared with corresponding central collisions. For mt=130 GeV we calculated a creation rate of about 4760 top-quark pairs per day at the LHC (3.5 TeV/nucleon) for Pb-Pb collisions
Self-energy correction to the hyperfine structure splitting of hydrogenlike atoms
A first testing ground for QED in the combined presence of a strong Coulomb field and a strong magnetic field is provided by the precise measurement of the hyperfine structure splitting of hydrogenlike 209Bi. We present a complete calculation of the one-loop self-energy correction to the first-order hyperfine interaction for various nuclear charges. In the low-Z regime we almost perfectly agree with the Z alpha expansion, but for medium and high Z there is a substantial deviation
Achieving diffraction-limited resolution in soft-X-ray Fourier-transform holography
The spatial resolution of microscopic images acquired via X-ray Fourier-transform holography is limited by the source size of the reference wave and by the numerical aperture of the detector. We analyze the interplay between both influences and show how they are matched in practice. We further identify, how high spatial frequencies translate to imaging artifacts in holographic reconstructions where mainly the reference beam limits the spatial resolution. As a solution, three methods are introduced based on numerical post-processing of the reconstruction. The methods comprise apodization of the hologram, refocusing via wave propagation, and deconvolution using the transfer function of the imaging system. In particular for the latter two, we demonstrate that image details smaller than the source size of the reference beam can be recovered up to the diffraction limit of the hologram. Our findings motivate the intentional application of a large reference-wave source enhancing the image contrast in applications with low photon numbers such as single-shot experiments at free-electron lasers or imaging at laboratory sources.BMBF, 05K10KTB, Verbundprojekt: FSP 301 - FLASH: Nanoskopische Systeme. Teilprojekt 1.1: Universelle Experimentierkammer für Streuexperimente mit kohärenten Femtosekunden-Röntgenpulsen Multi Purpose Coherent Scattering Chamber for FLASH and XFEL 'MPscatt
Experimental evaluation of signal-to-noise in spectro-holography via modified uniformly redundant arrays in the soft x-ray and extreme ultraviolet spectral regime
We present dichroic x-ray lensless magnetic imaging by Fourier transform holography with an extended reference scheme via a modified uniformly redundant array (mURA). Holographic images of magnetic domains simultaneously generated by a single pinhole reference as well as by a mURA reference are compared with respect to the signal-to-noise ratio (SNR) as a function of exposure time. We apply this approach for spectro-holographic imaging of ferromagnetic domain patterns in Co/Pt multilayer films. Soft x-rays with wavelengths of 1.59 nm (Co L 3 absorption edge) and 20.8 nm (Co M 2,3 absorption edges) are used for image formation and to generate contrast via x-ray magnetic circular dichroism. For a given exposure time, the mURA-based holography allows to decouple the reconstruction SNR from the spatial resolution. For 1.59 nm wavelength, the reconstruction via the extended reference scheme shows no significant loss of spatial resolution compared to the single pinhole reference. In contrast, at 20.8 nm wavelength the single pinhole reveals some very intricate features which are lost in the image generated by the mURA, although overall a high-quality image is generated. The SNR-advantage of the mURA scheme is most notable when the hologram has to be encoded with few photons, while errors associated with the increased complexity of the reconstruction process reduce the advantage for high-photon-number experiments.BMBF, 05K13KT3, Verbundprojekt 05K2013 - DynaMaX: Messplatz fĂĽr ultraschnelle Dynamik bei BESSY II. Teilprojekt
Wigner crystal vs. Friedel oscillations in the 1D Hubbard model
We analyze the fermion density of the one-dimensional Hubbard model using
bosonization and numerical DMRG calculations. For finite systems we find a
relatively sharp crossover even for moderate short range interactions into a
region with density waves as a function of density. The results show
that the unstable fixed point of a spin-incoherent state can dominate the
physical behavior in a large region of parameter space in finite systems. The
crossover may be observable in ultra cold fermionic gases in optical lattices
and in finite quantum wires.Comment: 6 pages, 6 figures. Published version. The most recent file can be
found at http://www.physik.uni-kl.de/eggert/papers/index.htm
Nanoparticle detection in an open-access silicon microcavity
We report on the detection of free nanoparticles in a micromachined,
open-access Fabry-P\'erot microcavity. With a mirror separation of m,
a radius of curvature of mm, and a beam waist of m, the mode
volume of our symmetric infrared cavity is smaller than pL. The small
beam waist, together with a finesse exceeding 34,000, enables the detection of
nano-scale dielectric particles in high vacuum. This device allows monitoring
of the motion of individual nm radius silica nanospheres in real time.
We observe strong coupling between the particles and the cavity field, a
precondition for optomechanical control. We discuss the prospects for optical
cooling and detection of dielectric particles smaller than nm in radius
and amu in mass.Comment: 4 pages, 3 figure
- …