746 research outputs found

    The Development of a Universally Accepted Sacral Fracture Classification: A Survey of AOSpine and AOTrauma Members.

    Get PDF
    Study Design Survey study. Objective To determine the global perspective on controversial aspects of sacral fracture classifications. Methods While developing the AOSpine Sacral Injury Classification System, a survey was sent to all members of AOSpine and AOTrauma. The survey asked four yes-or-no questions to help determine the best way to handle controversial aspects of sacral fractures in future classifications. Chi-square tests were initially used to compare surgeons\u27 answers to the four key questions of the survey, and then the data was modeled through multivariable logistic regression analysis. Results A total of 474 surgeons answered all questions in the survey. Overall 86.9% of respondents felt that the proposed hierarchical nature of injuries was appropriate, and 77.8% of respondents agreed that that the risk of neurologic injury is highest in a vertical fracture through the foramen. Almost 80% of respondents felt that the separation of injuries based on the integrity of L5-S1 facet was appropriate, and 83.8% of surgeons agreed that a nondisplaced sacral U fracture is a clinically relevant entity. Conclusion This study determines the global perspective on controversial areas in the injury patterns of sacral fractures and demonstrates that the development of a comprehensive and universally accepted sacral classification is possible

    Sacral Fractures and Associated Injuries.

    Get PDF
    STUDY DESIGN: Literature review. OBJECTIVE: The aim of this review is to describe the injuries associated with sacral fractures and to analyze their impact on patient outcome. METHODS: A comprehensive narrative review of the literature was performed to identify the injuries associated with sacral fractures. RESULTS: Sacral fractures are uncommon injuries that result from high-energy trauma, and that, due to their rarity, are frequently underdiagnosed and mistreated. Only 5% of sacral fractures occur in isolation. Injuries most often associated with sacral fractures include neurologic injuries (present in up to 50% of sacral fractures), pelvic ring disruptions, hip and lumbar spine fractures, active pelvic/ abdominal bleeding and the presence of an open fracture or significant soft tissue injury. Diagnosis of pelvic ring fractures and fractures extending to the lumbar spine are key factors for the appropriate management of sacral fractures. Importantly, associated systemic (cranial, thoracic, and abdominopelvic) or musculoskeletal injuries should be promptly assessed and addressed. These associated injuries often dictate the management and eventual outcome of sacral fractures and, therefore, any treatment algorithm should take them into consideration. CONCLUSIONS: Sacral fractures are complex in nature and often associated with other often-missed injuries. This review summarizes the most relevant associated injuries in sacral fractures and discusses on their appropriate management

    Impact of Anxiety During Hospitalization on the Clinical Outcome of Patients With Osteoporotic Thoracolumbar Vertebral Fracture

    Full text link
    STUDY DESIGN: Multicenter prospective cohort study. OBJECTIVES: Anxiety in combination with osteoporotic vertebral compression fractures (OVCFs) of the spine remains understudied. The purpose of this study was to analyze whether anxiety has an impact on the short-term functional outcome of patients with an OVCF. Furthermore, a direct impact of the fracture on the patient's anxiety during hospitalization should be recognized. METHODS: All inpatients with an OVCF of the thoracolumbar spine from 2017 to 2020 were included. Trauma mechanism, analgetic medication, anti-osteoporotic therapy, timed-up-and-go test (TuG), mobility, Barthel index, Oswestry-Disability Index (ODI) and EQ5D-5L were documented.For statistical analysis, the U test, chi-square independence test, Spearman correlation, General Linear Model for repeated measures, Bonferroni analysis and Wilcoxon test were used. The item anxiety/depression of the EQ5D-5L was analyzed to describe the patients' anxiousness. RESULTS: Data from 518 patients from 17 different hospitals were evaluated. Fracture severity showed a significant correlation (r = .087, P = .0496) with anxiety. During the hospital stay, pain medication (P < .001), anti-osteoporotic medication (P < .001), and initiation of surgical therapy (P < .001) were associated with less anxiety. The anxiety of a patient at discharge was negatively related to the functional outcomes at the individual follow-up: TuG (P < .001), Barthel index (P < .001), ODI (P < .001) and EQ5D-5L (P < .001). CONCLUSIONS: Higher anxiety is associated with lower functional outcome after OVCF. The item anxiety/depression of the EQ5D-5L provides an easily accessible, quick and simple tool that can be used to screen for poor outcomes and may also offer the opportunity for a specific anxiety intervention

    Incidence, Risk Factors, and Impact of Severe Neutropenia After Hyperthermic Intraperitoneal Mitomycin C

    Get PDF
    Cytoreductive surgery (CRS) and hyperthermic intraperitoneal chemotherapy (HIPEC) are considered the standard of care for patients with peritoneal dissemination of appendiceal cancer and are increasingly being evaluated for use in patients with carcinomatosis from colon cancer. Mitomycin C (MMC) is one of the most frequently used HIPEC agents in the management of peritoneal-based gastrointestinal malignancies. This study analyzes the incidence and risk factors for developing neutropenia following MMC-HIPEC combined with CRS. All patients undergoing CRS and MMC-HIPEC for appendiceal cancer between January 1993 and October 2006 were retrospectively reviewed. Logistic regression was used to identify risk factors for the development of neutropenia, defined as an absolute neutrophil count (ANC) &lt;1,000/mm3. One hundred and twenty MMC-HIPEC were performed in 117 patients with appendiceal cancer. The incidence of neutropenia was 39%. Neutropenia occurred in 57.6% of female and 21.3% of male patients (p &lt; 0.0001). Female gender and MMC dose per body surface area (BSA) were independent risk factors for neutropenia on multivariable logistic regression [odds ratio (OR) of neutropenia in females = 3.58 (95% confidence interval, CI: 1.52, 8.43); OR for 5 unit (mg/m2) increase in MMC dose per BSA = 3.37 (95% CI: 1.72, 6.63)]. Neutropenia did not increase the risk of mortality, postoperative infection or length of hospital stay. Neutropenia is a frequent complication associated with MMC-HIPEC. Female sex and MMC dose per BSA are independent risk factors for neutropenia. These differences must be considered in the management of patients undergoing MMC-HIPEC to minimize the toxicity of the procedure

    Development and reliability of the AOSpine CROST (Clinician Reported Outcome Spine Trauma): a tool to evaluate and predict outcomes from clinician’s perspective

    Get PDF
    Purpose: To report on the development of AOSpine CROST (Clinician Reported Outcome Spine Trauma) and results of an initial reliability study. Methods: The AOSpine CROST was developed using an iterative approach of multiple cycles of development, review, and revision including an expert clinician panel. Subsequently, a reliability study was performed among an expert panel who were provided with 20 spine trauma cases, administered twice with 4-week interval. The results of the developmental process were analyzed using descriptive statistics, the reliability per parameter using Kappa statistics, inter-rater rater agreement using intraclass correlation coefficient (ICC), and internal consistency using Cronbach’s α. Results: The AOSpine CROST was developed and consisted of 10 parameters, 2 of which are only applicable for surgically treated patents (‘Wound healing’ and ‘Implants’). A dichotomous scoring system (‘yes’ or ‘no’ response) was incorporated to express expected problems for the short term and long term. In the reliability study, 16 (84.2%) participated in the first round and 14 (73.7%) in the second. Intra-rater reliability was fair to good for both time points (Îș = 0.40–0.80 and Îș = 0.31–0.67). Results of inter-rater reliability were lower (Îș = 0.18–0.60 and Îș = 0.16–0.46). Inter-rater agreement for total scores showed moderate results (ICC = 0.52–0.60), and the internal consistency was acceptable (α = 0.76–0.82). Conclusions: The AOSpine CROST, an outcome tool for the surgeons, was developed using an iterative process. An initial reliability analysis showed fair to moderate results and acceptable internal consistency. Further clinical validation studies will be performed to further validate the tool

    Search for a vector-like quark Tâ€Č → tH via the diphoton decay mode of the Higgs boson in proton-proton collisions at s \sqrt{s} = 13 TeV

    Get PDF
    A search for the electroweak production of a vector-like quark Tâ€Č, decaying to a top quark and a Higgs boson is presented. The search is based on a sample of proton-proton collision events recorded at the LHC at = 13 TeV, corresponding to an integrated luminosity of 138 fb−1. This is the first Tâ€Č search that exploits the Higgs boson decay to a pair of photons. For narrow isospin singlet Tâ€Č states with masses up to 1.1 TeV, the excellent diphoton invariant mass resolution of 1–2% results in an increased sensitivity compared to previous searches based on the same production mechanism. The electroweak production of a Tâ€Č quark with mass up to 960 GeV is excluded at 95% confidence level, assuming a coupling strength ÎșT = 0.25 and a relative decay width Γ/MTâ€Č < 5%

    Measurement of the Higgs boson inclusive and differential fiducial production cross sections in the diphoton decay channel with pp collisions at s \sqrt{s} = 13 TeV

    Get PDF
    The measurements of the inclusive and differential fiducial cross sections of the Higgs boson decaying to a pair of photons are presented. The analysis is performed using proton-proton collisions data recorded with the CMS detector at the LHC at a centre-of-mass energy of 13 TeV and corresponding to an integrated luminosity of 137 fb−1^{−1}. The inclusive fiducial cross section is measured to be σfidσ_{fid}=73.4−5.3+5.4^{+5.4}_{−5.3}(stat)−2.2+2.4^{+2.4}_{−2.2}(syst) fb, in agreement with the standard model expectation of 75.4 ± 4.1 fb. The measurements are also performed in fiducial regions targeting different production modes and as function of several observables describing the diphoton system, the number of additional jets present in the event, and other kinematic observables. Two double differential measurements are performed. No significant deviations from the standard model expectations are observed

    A search for new physics in central exclusive production using the missing mass technique with the CMS detector and the CMS-TOTEM precision proton spectrometer

    Get PDF
    A generic search is presented for the associated production of a Z boson or a photon with an additional unspecified massive particle X, pp → pp + Z/γ + X, in proton-tagged events from proton–proton collisions at √s = 13 TeV, recorded in 2017 with the CMS detector and the CMS-TOTEM precision proton spectrometer. The missing mass spectrum is analysed in the 600–1600 GeV range and a fit is performed to search for possible deviations from the background expectation. No significant excess in data with respect to the background predictions has been observed. odelindependent upper limits on the visible production cross section of pp → pp + Z/γ + X are set

    Search for a right-handed W boson and a heavy neutrino in proton-proton collisions at s \sqrt{s} = 13 TeV

    Get PDF
    A search is presented for a right-handed W boson (WR) and a heavy neutrino (N), in a final state consisting of two same-flavor leptons (ee or ΌΌ) and two quarks. The search is performed with the CMS experiment at the CERN LHC using a data sample of proton-proton collisions at a center-of-mass energy of 13 TeV corresponding to an integrated luminosity of 138 fb−1. The search covers two regions of phase space, one where the decay products of the heavy neutrino are merged into a single large-area jet, and one where the decay products are well separated. The expected signal is characterized by an excess in the invariant mass distribution of the final-state objects. No significant excess over the standard model background expectations is observed. The observations are interpreted as upper limits on the product of WR production cross sections and branching fractions assuming that couplings are identical to those of the standard model W boson. For N masses mN equal to half the WR mass mWR (mN = 0.2 TeV), mWR is excluded at 95% confidence level up to 4.7 (4.8) and 5.0 (5.4) TeV for the electron and muon channels, respectively. This analysis provides the most stringent limits on the WR mass to date
    • 

    corecore