2,166 research outputs found

    Photocathodes for a post-processed imaging array

    Get PDF
    Preliminary results of a photon detector combining a Micromegas like multiplier coated with a UV-sensitive CsI photocathode are described. The multiplier is made in the CMOS compatible InGrid technology, which allows to post-process it directly on the surface of an imaging IC. This method is aimed at building light-sensitive imaging detectors where all elements are monolithically integrated. We show that the CsI photocathode deposited in the InGrid mesh does not alter the device performance. Maximum gains of ~6000 were reached in a singlegrid element operated in Ar/CH4, with a 2% Ion Back Flow fraction returning to the photocathode

    CHAP Enhances Versatility in Colloidal Probe Fabrication

    Get PDF
    A colloidal probe, comprising a colloidal particle attached to an atomic force microscope cantilever, is employed to measure directly interaction forces between the particle and a surface. It is possible to change or even destroy a particle while attaching it to a cantilever, thus limiting the types of systems to which the colloidal probe technique may be applied. Here we present the Controlled Heating and Alignment Platform (CHAP) for fabricating colloidal probes without altering the original characteristics of the attached particle. The CHAP applies heat directly to the atomic force microscope chip to rapidly and precisely control cantilever temperature. This minimizes particle heating and enables control over the viscosity of thermoplastic adhesive, to prevent it from contaminating the particle surface. 3D-printed components made the CHAP compatible with standard optical microscopes and streamlined the fabrication process while increasing the platforms versatility. Using the CHAP with a thermoplastic wax adhesive, colloidal probes were fabricated using polystyrene and silica particles between 0.7 and 40 m in diameter. We characterized the properties and interactions of the adhesive and particles, as well as the properties of the completed probes, to demonstrate the retention of particle features throughout fabrication. Pull-off tests with CHAPs probes measured adhesive force values in the expected ranges and demonstrated that particles were firmly attached to the cantilevers

    Improving Tracer Particle Surface Properties for Wind Tunnel Research

    Get PDF
    The surface properties of micron size polystyrene latex microspheres (PSLs) modified with quaternary alkylammonium (QA) surfactants were investigated, with a focus on the relationship between surface chemistry and adhesion. These investigations were motivated by the need to develop non-fouling tracer particles for wind tunnel studies. The goals were to relate the work of adhesion between particles and substrates to the type and amount of QA modifier in order to optimize the performance of PSL tracers. Surfactant-free emulsion polymerization (SFEP) can produce PSLs for wind tunnel tracers. Covalentlybound charged groups (derived from the initiator) stabilize PSL surfaces in water. This work used PSLs with anionic surface groups. Previous studies indicated that surface-bound charged groups on PSLs have a significant impact on their interfacial energy. Modifying charged surface groups therefore offers a method to modulate PSL interfacial properties. In this work, PSLs and films were modified by adsorption of QA surfactants

    A Radiation Imaging Detector Made by Postprocessing a Standard CMOS Chip

    Get PDF
    An unpackaged microchip is used as the sensing element in a miniaturized gaseous proportional chamber. Thisletter reports on the fabrication and performance of a complete radiation imaging detector based on this principle. Our fabrication schemes are based on wafer-scale and chip-scale postprocessing.\ud Compared to hybrid-assembled gaseous detectors, our microsystem shows superior alignment precision and energy resolution, and offers the capability to unambiguously reconstruct 3-D radiation tracks on the spot.\u

    Reduction of Wind Tunnel Contamination During Flow Visualization Experiments Using Polystyrene Microspheres

    Get PDF
    Evaluation of novel methods and materials for seeding tracer particles for particle image velocimetry (PIV) was carried out in the Basic Aerodynamic Research Tunnel (BART) at NASAs Langley Research Center (LaRC). Seeding of polystyrene latex microspheres (PSLs) from ethanol/water suspensions and from the dry state was carried out using custom built seeders. PIV data generated using the novel methods were found to be in general agreement with data collected using the current seeding methods. Techniques for assessing PSL fouling of wind tunnel surfaces were identified and refined. Initial results suggest that dry seeding PSLs may allow comparable data quality to wet seeding while reducing wind tunnel screen fouling. Results also indicate that further developments to the dry seeding system should focus on increasing single particle flux into the wind tunnel. Modifications to PSLs and seeding equipment to achieve this have been identified and are discussed

    Measuring Work of Adhesion of Polystyrene Microspheres

    Get PDF
    Particle adhesion is relevant in fields ranging from aerospace and energy to civil engineering and medicine. The functions of aerodynamic surfaces, heat exchangers, solar panels, ventilation systems, and blood vessels are affected by the buildup of particulates on their surfaces. Direct measurement of the adhesive force between a particle and a surface is key to understanding and mitigating particle fouling. Approaches such as the Johnson-Kendall-Roberts (JKR) and Derjaguin-Muller-Toporov (DMT) models offer a first approximation of the forces involved but do not account for non-idealities like roughness or plastic deformation. Experimental measurements of adhesive forces often deviate significantly from predictions. One approach to measure adhesion is the colloidal probe technique, which uses a particle attached to the tip of an atomic force microscope (AFM) cantilever. The particle is touched to a surface and then withdrawn and a pull-off force (FPO) determined by cantilever deflection. FPO can be used to estimate work of adhesion (Wa) and other properties from existing models. We describe a new method for producing colloidal probes using wax as an adhesive to attach micrometer-scale spheres to AFM tips. This method can be used with a range of particles and minimizes the potential for changes to the particle surface chemistry or geometry from exposure to heat, chemicals, radiation, or external forces. Particle attachment to AFM tips is robust and reversible, allowing old particles to be replaced with new ones in a few minutes. Pull-off measurements using polystyrene (PS) particles, pristine and modified with myristyltrimethylammonium bromide (14-TAB), were collected from various substrates to demonstrate the viability of this technique and investigate the impact of particle surface modification

    Chronic motor neuropathies: response to interferon-beta1a after failure of conventional therapies

    Get PDF
    OBJECTIVES: The effect of interferon-beta1a (INF-beta1a; Rebif) was studied in patients with chronic motor neuropathies not improving after conventional treatments such as immunoglobulins, steroids, cyclophosphamide or plasma exchange. METHODS: A prospective open study was performed with a duration of 6-12 months. Three patients with a multifocal motor neuropathy and one patient with a pure motor form of chronic inflammatory demyelinating polyneuropathy were enrolled. Three patients had anti-GM1 antibodies. Treatment consisted of subcutaneous injections of IBF-beta1a (6 MIU), three times a week. Primary outcome was assessed at the level of disability using the nine hole peg test, the 10 metres walking test, and the modified Rankin scale. Secondary outcome was measured at the impairment level using a slightly modified MRC sumscore. RESULTS: All patients showed a significant improvement on the modified MRC sumscore. The time required to walk 10 metres and to fulfil the nine hole peg test was also significantly reduced in the first 3 months in most patients. However, the translation of these results to functional improvement on the modified Rankin was only seen in two patients. There were no severe adverse events. Motor conduction blocks were partially restored in one patient only. Anti-GM1 antibody titres did not change. CONCLUSION: These findings indicate that severely affected patients with chronic motor neuropathies not responding to conventional therapies may improve when treated with INF-beta1a. From this study it is suggested that INF-beta1a should be administered in patients with chronic motor neuropathies for a period of up to 3 months before deciding to cease treatment. A controlled trial is necessary to confirm these findings
    • 

    corecore