110 research outputs found

    Annex to Quirke et al. Quality assurance in pathology in colorectal cancer screening and diagnosis: annotations of colorectal lesions

    Get PDF
    Multidisciplinary, evidence-based European Guidelines for quality assurance in colorectal cancer screening and diagnosis have recently been developed by experts in a pan-European project coordinated by the International Agency for Research on Cancer. The full guideline document includes a chapter on pathology with pan-European recommendations which take into account the diversity and heterogeneity of health care systems across the EU. The present paper is based on the annex to the pathology chapter which attempts to describe in greater depth some of the issues raised in the chapter in greater depth, particularly details of special interest to pathologists. It is presented here to make the relevant discussion known to a wider scientific audience

    Dynamic clonal equilibrium and predetermined cancer risk in Barrett's oesophagus

    Get PDF
    abstract: Surveillance of Barrett’s oesophagus allows us to study the evolutionary dynamics of a human neoplasm over time. Here we use multicolour fluorescence in situ hybridization on brush cytology specimens, from two time points with a median interval of 37 months in 195 non-dysplastic Barrett's patients, and a third time point in a subset of 90 patients at a median interval of 36 months, to study clonal evolution at single-cell resolution. Baseline genetic diversity predicts progression and remains in a stable dynamic equilibrium over time. Clonal expansions are rare, being detected once every 36.8 patient years, and growing at an average rate of 1.58 cm[superscript 2] (95% CI: 0.09–4.06) per year, often involving the p16 locus. This suggests a lack of strong clonal selection in Barrett’s and that the malignant potential of ‘benign’ Barrett’s lesions is predetermined, with important implications for surveillance programs.The final version of this article, as published in Nature Communications, can be viewed online at: https://www.nature.com/articles/ncomms1215

    Efficacy of capillary pattern type IIIA/IIIB by magnifying narrow band imaging for estimating depth of invasion of early colorectal neoplasms

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Capillary patterns (CP) observed by magnifying Narrow Band Imaging (NBI) are useful for differentiating non-adenomatous from adenomatous colorectal polyps. However, there are few studies concerning the effectiveness of magnifying NBI for determining the depth of invasion in early colorectal neoplasms. We aimed to determine whether CP type IIIA/IIIB identified by magnifying NBI is effective for estimating the depth of invasion in early colorectal neoplasms.</p> <p>Methods</p> <p>A series of 127 consecutive patients with 130 colorectal lesions were evaluated from October 2005 to October 2007 at the National Cancer Center Hospital East, Chiba, Japan. Lesions were classified as CP type IIIA or type IIIB according to the NBI CP classification. Lesions were histopathologically evaluated. Inter and intraobserver variabilities were assessed by three colonoscopists experienced in NBI.</p> <p>Results</p> <p>There were 15 adenomas, 66 intramucosal cancers (pM) and 49 submucosal cancers (pSM): 16 pSM superficial (pSM1) and 33 pSM deep cancers (pSM2-3). Among lesions diagnosed as CP IIIA 86 out of 91 (94.5%) were adenomas, pM-ca, or pSM1; among lesions diagnosed as CP IIIB 28 out of 39 (72%) were pSM2-3. Sensitivity, specificity and diagnostic accuracy of the CP type III for differentiating pM-ca or pSM1 (<1000 μm) from pSM2-3 (≥1000 μm) were 84.8%, 88.7 % and 87.7%, respectively. Interobserver variability: κ = 0.68, 0.67, 0.72. Intraobserver agreement: κ = 0.79, 0.76, 0.75</p> <p>Conclusion</p> <p>Identification of CP type IIIA/IIIB by magnifying NBI is useful for estimating the depth of invasion of early colorectal neoplasms.</p

    CT colonography with minimal bowel preparation: evaluation of tagging quality, patient acceptance and diagnostic accuracy in two iodine-based preparation schemes

    Get PDF
    PURPOSE: The aim of this study was to compare a 1-day with a 2-day iodine bowel preparation for CT colonography in a positive faecal occult blood test (FOBT) screening population. MATERIALS AND METHODS: One hundred consecutive patients underwent CT colonography and colonoscopy with segmental unblinding. The first 50 patients (group 1) ingested 7 50 ml iodinated contrast starting 2 days before CT colonography. The latter 50 patients (group 2) ingested 4 50 ml iodinated contrast starting 1 day before CT colonography. Per colonic segment measurements of residual stool attenuation and homogeneity were performed, and a subjective evaluation of tagging quality (grade 1-5) was done. Independently, two reviewers performed polyp and carcinoma detection. RESULTS: The tagging density was 638 and 618 HU (p = 0.458) and homogeneity 91 and 86 HU for groups 1 and 2, respectively (p = 0.145). The tagging quality was graded 5 (excellent) in 90% of all segments in group 1 and 91% in group 2 (p = 0.749). Mean per-polyp sensitivity for lesions >or=10 mm was 86% in group 1 and 97% in group 2 (p = 0.355). Patient burden from diarrhoea significantly decreased for patients in group 2. CONCLUSIONS: One-day preparation with meglumine ioxithalamate results in an improved patient acceptability compared with 2-day preparation and has a comparable, excellent image quality and good diagnostic performanc

    Progression of duodenal adenomatosis in familial adenomatous polyposis: due to ageing of subjects and advances in technology

    Get PDF
    Familial adenomatous polyposis patients are at risk of duodenal cancer. Surveillance is indicated and the extent of duodenal polyposis is quantified by the Spigelman staging system. We noticed an impressive increase in high Spigelman stages over the years and therefore decided to investigate whether this increase might be due to the time-lapse since the inception of surveillance or related to improvements in endoscopic imaging and/or changes in dysplasia-reporting. Patients who were investigated by the same endoscopist since 1980 in at least 2 different episodes of technical improvements were eligible. The period 1980–2009 was divided into 4 episodes using the following landmarks: replacement of fibre-endoscopes by video-endoscopes in 1987, change in processors in 1995, change in image resolution in 2000, and change in dysplasia-reporting in 2006. An increase in Spigelman stages from low stages (0–II 100%) to high stages (III 28.1%, IV 43.8%) was seen (median follow-up: 19.5 years). In patients who progressed, a median of 4 years elapsed before progression by one stage occurred and 7 years to progress by two stages. In a mixed-model analysis, both time-lapse and technical improvements were determinant factors for duodenal disease progression. When both factors were introduced in the model, the time-lapse as well as the change in image resolution and dysplasia-ranking contributed consistently in increasing Spigelman scores and stages. The impressive increase in severity of duodenal polyposis is determined by time-lapse, technological advances and change in dysplasia-reporting. These results might call for a revised Spigelman classification

    Narrow band imaging for the detection of gastric intestinal metaplasia and dysplasia during surveillance endoscopy

    Get PDF
    Background: Surveillance of premalignant gastric lesions relies mainly on random biopsy sampling. Narrow band imaging (NBI) may enhance the accuracy of endoscopic surveillance of intestinal metaplasia (IM) and dysplasia. We aimed to compare the yield of NBI to white light endoscopy (WLE) in the surveillance of patients with IM and dysplasia. Methods: Patients with previously identified gastric IM or dysplasia underwent a surveillance endoscopy. Both WLE and NBI were performed in all patients during a single procedure. The sensitivity of WLE and NBI for the detection of premalignant lesions was calculated by correlating endoscopic findings to histological diagnosis. Results: Forty-three patients (28 males and 15 females, mean age 59 years) were included. IM was diagnosed in 27 patients; 20 were detected by NBI and WLE, four solely by NBI and three by random biopsies only. Dysplasia was detected in seven patients by WLE and NBI and in two patients by random biopsies only. Sixty-eight endoscopically detected lesions contained IM: 47 were detected by WLE and NBI, 21 by NBI only. Nine endoscopically detected lesions demonstrated dysplasia: eight were detected by WLE and NBI, one was detected by NBI only. The sensitivity, specificity, positive and negative predictive values for detection of premalignant lesions were 71, 58, 65 and 65% for NBI and 51, 67, 62 and 55% for WLE, respectively. Conclusions: NBI increases the diagnostic yield for detection of advanced premalignant gastric lesions compared to routine WLE

    CT colonography with limited bowel preparation for the detection of colorectal neoplasia in an FOBT positive screening population

    Get PDF
    Item does not contain fulltextPURPOSE: Aim was to evaluate the accuracy of computed tomography colonography (CTC) for detection of colorectal neoplasia in a Fecal Occult Blood Test (FOBT) positive screening population. METHODS: In three different institutions, consecutive FOBT positives underwent CTC after laxative free iodine tagging bowel preparation followed by colonoscopy with segmental unblinding. Each CTC was read by two experienced observers. For CTC and for colonoscopy the per-polyp sensitivity and per-patient sensitivity and specificity were calculated for detection of carcinomas, advanced adenomas, and adenomas. RESULTS: In total 22 of 302 included FOBT positive participants had a carcinoma (7%) and 137 had an adenoma or carcinoma >/=10 mm (45%). CTC sensitivity for carcinoma was 95% with one rectal carcinoma as false negative finding. CTC sensitivity for advanced adenomas was 92% (95% CI: 88-96) vs. 96% (95% CI: 93-99) for colonoscopy (P = 0.26). For adenomas and carcinomas >/=10 mm the CTC per-polyp sensitivity was 93% (95% CI: 89-97) vs. 97% (95% CI: 94-99) for colonoscopy (P = 0.17). The per-patient sensitivity for the detection of adenomas and carcinomas >/=10 mm was 95% (95% CI: 91-99) for CTC vs. 99% (95% CI: 98-100) for colonoscopy (P = 0.07), while the per-patient specificity was 90% (95% CI: 86-95) and 96% (95% CI: 94-99), respectively (P < 0.001). CONCLUSION: CTC with limited bowel preparation performed in an FOBT positive screening population has high diagnostic accuracy for the detection of adenomas and carcinomas and a sensitivity similar to that of colonoscopy for relevant lesions.1 december 201

    Telomerase activity of the Lugol-stained and -unstained squamous epithelia in the process of oesophageal carcinogenesis

    Get PDF
    Up-regulation of telomerase has been reported in many cancers. Our aim was to characterize telomerase activity in various states of the oesophagus to facilitate better understanding of carcinogenesis of oesophageal squamous cell carcinoma. During endoscopic examinations, we obtained 45 Lugol-stained normal epithelia, 31 Lugol-unstained epithelia (14 oesophagitis, 7 mild dysplasia, 5 severe dysplasia and 5 intramucosal cancer) and 9 advanced cancer. Telomerase activity was semi-quantified by a telomeric repeat amplification protocol using enzyme-linked immunosorbent assay, and expression of human telomerase reverse transcriptase mRNA was examined by in situ hybridization. In the Lugol-stained normal epithelia, telomerase activity increased in proportion to the increase of severity of the accompanying lesions, with a rank order of advanced cancer, intramucosal cancer, mild dysplasia and oesophagitis. In the Lugol-unstained lesions and advanced cancer, telomerase activity was highest in advanced cancer. Up-regulation of telomerase in normal squamous epithelium may be a marker of progression of oesophageal squamous cell carcinoma. Copyright 2001 Cancer Research Campaign © 2001 Cancer Research Campaignhttp://www.bjcancer.co
    corecore