956 research outputs found
The 10 Tesla muSR instrument: detector solutions
Solutions to the detector system of the High-Field muSR instrument at the
Paul Scherrer Institut (PSI) in Switzerland are presented. The strict technical
requirements are fulfilled through the application of Geiger-mode Avalanche
Photodiodes.Comment: 6 pages, 4 figure
A time-resolution study with a plastic scintillator read out by a Geiger-mode Avalanche Photodiode
In this work we attempt to establish the best time resolution attainable with
a scintillation counter consisting of a plastic scintillator read out by a
Geiger-mode Avalanche Photodiode. The measured time resolution is inversely
proportional to the square root of the energy deposited in the scintillator,
and scales to 18ps (sigma) at 1MeV. This result competes with the best ones
reported for photomultiplier tubes.Comment: 8 pages, 8 figure
The new versatile general purpose surface-muon instrument (GPS) based on silicon photomultipliers for SR measurements on a continuous-wave beam
We report on the design and commissioning of a new spectrometer for muon-spin
relaxation/rotation studies installed at the Swiss Muon Source (SS) of the
Paul Scherrer Institute (PSI, Switzerland). This new instrument is essentially
a new design and replaces the old general-purpose surface-muon instrument (GPS)
which has been for long the workhorse of the SR user facility at PSI. By
making use of muon and positron detectors made of plastic scintillators read
out by silicon photomultipliers (SiPMs), a time resolution of the complete
instrument of about 160 ps (standard deviation) could be achieved. In addition,
the absence of light guides, which are needed in traditionally built SR
instrument to deliver the scintillation light to photomultiplier tubes located
outside magnetic fields applied, allowed us to design a compact instrument with
a detector set covering an increased solid angle compared to the old GPS.Comment: 11 pages, 11 figure
Probing the magnetic ground state of the molecular Dysprosium triangle
We present zero field muon spin lattice relaxation measurements of a
Dysprosium triangle molecular magnet. The local magnetic fields sensed by the
implanted muons indicate the coexistence of static and dynamic internal
magnetic fields below K. Bulk magnetization and heat capacity
measurements show no indication of magnetic ordering below this temperature. We
attribute the static fields to the slow relaxation of the magnetization in the
ground state of Dy3. The fluctuation time of the dynamic part of the field is
estimated to be ~0.55 s at low temperaturesComment: 5 pages, 5 figures, accepted for publication in Phys. Rev.
The comparative analysis of shod products on the example of the historical cities of Russia
In article art forging as an art form and as the integral element of creation of an urban environment is considered. The review of the existing samples of forge craft in the cities of Suzdal, Tomsk, Moscow, St. Petersburg, their features and styles is carried out
Raças fisiológicas e linhagens de uma população contemporânea de Magnaporthe oryzae associada à brusone do arroz irrigado no Sul do Brasil.
Objetivou-se identificar raças fisiológicas, com base em séries diferenciadoras, e linhagens, com base em marcadores microssatélites, em uma população de Magnaporthe oryzae do sul do Brasil
- …