1,486 research outputs found

    Analytical Solution for the Deformation of a Cylinder under Tidal Gravitational Forces

    Get PDF
    Quite a few future high precision space missions for testing Special and General Relativity will use optical resonators which are used for laser frequency stabilization. These devices are used for carrying out tests of the isotropy of light (Michelson-Morley experiment) and of the universality of the gravitational redshift. As the resonator frequency not only depends on the speed of light but also on the resonator length, the quality of these measurements is very sensitive to elastic deformations of the optical resonator itself. As a consequence, a detailed knowledge about the deformations of the cavity is necessary. Therefore in this article we investigate the modeling of optical resonators in a space environment. Usually for simulation issues the Finite Element Method (FEM) is applied in order to investigate the influence of disturbances on the resonator measurements. However, for a careful control of the numerical quality of FEM simulations a comparison with an analytical solution of a simplified resonator model is beneficial. In this article we present an analytical solution for the problem of an elastic, isotropic, homogeneous free-flying cylinder in space under the influence of a tidal gravitational force. The solution is gained by solving the linear equations of elasticity for special boundary conditions. The applicability of using FEM codes for these simulations shall be verified through the comparison of the analytical solution with the results gained within the FEM code.Comment: 23 pages, 3 figure

    Antibacterial 45S5 Bioglass®-based scaffolds reinforced with genipin cross-linked gelatin for bone tissue engineering

    No full text
    45S5 Bioglass® (BG) scaffolds with high porosity (>90%) were coated with genipin cross-linked gelatin (GCG) and further incorporated with poly(p-xylyleneguanidine) hydrochloride (PPXG). The obtained GCG coated scaffolds maintained the high porosity and well interconnected pore structure. A 26-fold higher compressive strength was provided to 45S5 BG scaffolds by GCG coating, which slightly retarded but did not inhibit the in vitro bioactivity of 45S5 BG scaffolds in SBF. Moreover, the scaffolds were made antibacterial against both Gram-positive and Gram-negative bacteria by using polyguanidine, i.e. PPXG, in this study. Osteoblast-like cells (MG-63) were seeded onto PPXG and GCG coated scaffolds. PPXG was biocompatible with MG-63 cells at a low concentration (10 μg mL−1). MG-63 cells were shown to attach and spread on both uncoated and GCG coated scaffolds, and the mitochondrial activity measurement indicated that GCG coating had no negative influence on the cell proliferation behavior of MG-63 cells. The developed novel antibacterial bioactive 45S5 BG-based composite scaffolds with improved mechanical properties are promising candidates for bone tissue engineering

    A bayesian meta-analysis of multiple treatment comparisons of systemic regimens for advanced pancreatic cancer

    Get PDF
    © 2014 Chan et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.Background: For advanced pancreatic cancer, many regimens have been compared with gemcitabine (G) as the standard arm in randomized controlled trials. Few regimens have been directly compared with each other in randomized controlled trials and the relative efficacy and safety among them remains unclear

    Oral capecitabine as an alternative to i.v. 5-fluorouracil-based adjuvant therapy for colon cancer: safety results of a randomized, phase III trial

    Get PDF
    Background: Oral capecitabine achieves a superior response rate with an improved safety profile compared with bolus 5-fluorouracil-leucovorin (5-FU/LV) as first-line treatment for patients with metastatic colorectal cancer. We report here the results of a large phase III trial investigating adjuvant oral capecitabine compared with 5-FU/LV (Mayo Clinic regimen) in Dukes' C colon cancer. Patients and methods: Patients aged 18-75 years with resected Dukes' C colon carcinoma were randomized to receive 24 weeks of treatment with either oral capecitabine 1250 mg/m2 twice daily, days 1-14 every 21 days (n = 993), or i.v. bolus 5-FU 425 mg/m2 with i.v. leucovorin 20 mg/m2 on days 1-5, repeated every 28 days (n = 974). Results: Patients receiving capecitabine experienced significantly (P <0.001) less diarrhea, stomatitis, nausea/vomiting, alopecia and neutropenia, but more hand-foot syndrome than those receiving 5-FU/LV. Fewer patients receiving capecitabine experienced grade 3 or 4 neutropenia, febrile neutropenia/sepsis and stomatitis (P <0.001), although more experienced grade 3 hand-foot syndrome than those treated with 5-FU/LV (P <0.001). Capecitabine demonstrates a similar, favorable safety profile in patients aged <65 years or ≥65 years old. Conclusions: Based on its improved safety profile, capecitabine has the potential to replace 5-FU/LV as standard adjuvant treatment for patients with colon cancer. Efficacy results are expected to be available in 2004. Keywords: Adjuvant treatment, capecitabine, chemotherapy, colorectal cance

    Epidemiology and natural history of central venous access device use and infusion pump function in the NO16966 trial

    Get PDF
    Background: Central venous access devices in fluoropyrimidine therapy are associated with complications; however, reliable data are lacking regarding their natural history, associated complications and infusion pump performance in patients with metastatic colorectal cancer.&lt;p&gt;&lt;/p&gt; Methods: We assessed device placement, use during treatment, associated clinical outcomes and infusion pump perfomance in the NO16966 trial.&lt;p&gt;&lt;/p&gt; Results: Device replacement was more common with FOLFOX-4 (5-fluorouracil (5-FU)+oxaliplatin) than XELOX (capecitabine+oxaliplatin) (14.1% vs 5.1%). Baseline device-associated events and post-baseline removal-/placement-related events occurred more frequently with FOLFOX-4 than XELOX (11.5% vs 2.4% and 8.5% vs 2.1%). Pump malfunctions, primarily infusion accelerations in 16% of patients, occurred within 1.6–4.3% of cycles. Fluoropyrimidine-associated grade 3/4 toxicity was increased in FOLFOX-4-treated patients experiencing a malfunction compared with those who did not (97 out of 155 vs 452 out of 825 patients), predominantly with increased grade 3/4 neutropenia (53.5% vs 39.8%). Febrile neutropenia rates were comparable between patient cohorts±malfunction. Efficacy outcomes were similar in patient cohorts±malfunction.&lt;p&gt;&lt;/p&gt; Conclusions: Central venous access device removal or replacement was common and more frequent in patients receiving FOLFOX-4. Pump malfunctions were also common and were associated with increased rates of grade 3/4 haematological adverse events. Oral fluoropyrimidine-based regimens may be preferable to infusional 5-FU based on these findings

    Evaluating predictive pharmacogenetic signatures of adverse events in colorectal cancer patients treated with fluoropyrimidines

    Get PDF
    The potential clinical utility of genetic markers associated with response to fluoropyrimidine treatment in colorectal cancer patients remains controversial despite extensive study. Our aim was to test the clinical validity of both novel and previously identified markers of adverse events in a broad clinical setting. We have conducted an observational pharmacogenetic study of early adverse events in a cohort study of 254 colorectal cancer patients treated with 5-fluorouracil or capecitabine. Sixteen variants of nine key folate (pharmacodynamic) and drug metabolising (pharmacokinetic) enzymes have been analysed as individual markers and/or signatures of markers. We found a significant association between TYMP S471L (rs11479) and early dose modifications and/or severe adverse events (adjusted OR = 2.02 [1.03; 4.00], p = 0.042, adjusted OR = 2.70 [1.23; 5.92], p = 0.01 respectively). There was also a significant association between these phenotypes and a signature of DPYD mutations (Adjusted OR = 3.96 [1.17; 13.33], p = 0.03, adjusted OR = 6.76 [1.99; 22.96], p = 0.002 respectively). We did not identify any significant associations between the individual candidate pharmacodynamic markers and toxicity. If a predictive test for early adverse events analysed the TYMP and DPYD variants as a signature, the sensitivity would be 45.5 %, with a positive predictive value of just 33.9 % and thus poor clinical validity. Most studies to date have been under-powered to consider multiple pharmacokinetic and pharmacodynamic variants simultaneously but this and similar individualised data sets could be pooled in meta-analyses to resolve uncertainties about the potential clinical utility of these markers

    First direct detection of an exoplanet by optical interferometry; Astrometry and K-band spectroscopy of HR8799 e

    Get PDF
    To date, infrared interferometry at best achieved contrast ratios of a few times 10410^{-4} on bright targets. GRAVITY, with its dual-field mode, is now capable of high contrast observations, enabling the direct observation of exoplanets. We demonstrate the technique on HR8799, a young planetary system composed of four known giant exoplanets. We used the GRAVITY fringe tracker to lock the fringes on the central star, and integrated off-axis on the HR8799e planet situated at 390 mas from the star. Data reduction included post-processing to remove the flux leaking from the central star and to extract the coherent flux of the planet. The inferred K band spectrum of the planet has a spectral resolution of 500. We also derive the astrometric position of the planet relative to the star with a precision on the order of 100μ\,\muas. The GRAVITY astrometric measurement disfavors perfectly coplanar stable orbital solutions. A small adjustment of a few degrees to the orbital inclination of HR 8799 e can resolve the tension, implying that the orbits are close to, but not strictly coplanar. The spectrum, with a signal-to-noise ratio of 5\approx 5 per spectral channel, is compatible with a late-type L brown dwarf. Using Exo-REM synthetic spectra, we derive a temperature of 1150±501150\pm50\,K and a surface gravity of 104.3±0.310^{4.3\pm0.3}\,cm/s2^{2}. This corresponds to a radius of 1.170.11+0.13RJup1.17^{+0.13}_{-0.11}\,R_{\rm Jup} and a mass of 104+7MJup10^{+7}_{-4}\,M_{\rm Jup}, which is an independent confirmation of mass estimates from evolutionary models. Our results demonstrate the power of interferometry for the direct detection and spectroscopic study of exoplanets at close angular separations from their stars.Comment: published in A&
    corecore