    ICDs at higher age and clinical risk factors

    Get PDF
    Background The implantable cardioverter defibrillator (ICD) is effective in preventing sudden cardiac death. However, in elderly patients (aged 75 years or older) the role of ICDs is still not well-defined and controversial. Methods We retrospectively analysed all clinical and survival data of all ICD patients who were ≥75 years at the date of implantation in the Erasmus MC, Rotterdam, the Netherlands and the University Hospital, Basel, Switzerland. Kaplan- Meier survival analysis was performed, and mortality predictors were identified. Mortality of the cohort was compared with a random sample of patients aged 60-70 years originating from the same database and to an age- and sex-matched cohort of Dutch persons. Results The study cohort consisted of 179 patients aged 75 years or older who were implanted between February 1999 and July 2008. The median follow-up time was 2.0 (IQR 2.8) years. Survival rates after 1, 2 and 3 years were 87, 82, 75 %, respectively. Survival was similar for primary and secondary prevention. Mortality in this study population could be predicted by combining four clinical risk factors: QRS duration >120 ms, NYHA class > II, renal failure and atrial fibrillation (AF). Survival was worse compared with the group of ICD patients aged 60-70 years and to the age- and sex-matched group of elderly persons. However, survival was not significantly worse when comparing elderly ICD patients without additional risk factors to the general population. Conclusions Elderly patients still have an acceptable survival probability independent of prevention indication, certainly if there are no additional clinical risk factors. The presence or absence of additional clinical risk factors should be taken into account when making the decision for imp

    Predicting Early Mortality Among Implantable Defibrillator Patients Treated With Cardiac Resynchronization Therapy

    Get PDF
    Background: The beneficial effects of a cardiac resynchronization defibrillator (CRT-D) in patients with heart failure, low left ventricular ejection fraction (LVEF), and wide QRS have clearly been established. Nevertheless, mortality r

    Application of the heart failure meta-score to predict prognosis in patients with cardiac resynchronization defibrillators

    Get PDF
    Background: The Heart Failure (HF) Meta-score may be useful in predicting prognosis in patients with primary prevention cardiac resynchronization defibrillators (CRT-D) considering the competing risk of appropriate defibrillator shock versus mortality. Methods: Data from 648 consecutive patients from two centers were used for the evaluation of the performance of the HF Meta-score. The primary endpoint was mortality and the secondary endpoint was time to first appropriate implantable cardioverter-defibrillator (ICD) shock or death without prior appropriate ICD shock. Fine-Gray model was used for competing risk regression analysis. Results: In the entire cohort, 237 patients died over a median follow-up of 5.2 years. Five-year cumulative incidence of mortality ranged from 12% to 53%, for quintiles 1 through 5 of the HF Meta-score, respectively (log-rank P < 0.001). Compared with the lowest quintile, mortality risk was higher in the highest quintile (HR 6.9; 95%CI 3.7–12.8). The HF Meta-score had excellent calibration, accuracy, and good discrimination in predicting mortality (C-statistic 0.76 at 1-year and 0.71 at 5-year). The risk of death without appropriate ICD shock was higher in risk quintile 5 compared to quintile 1 (sub HR 5.8; 95%CI 3.1–11.0, P < 0.001). Conclusions: Our study demonstrated a good ability of the HF Meta-score to predict survival in HF patients treated with CRT-D as primary prevention. The HF Meta-score proved to be useful in identifying a subgroup with a significantly poor prognosis despite a CRT-D

    Sex differences in outcomes of primary prevention implantable cardioverter-defibrillator therapy:combined registry data from eleven European countries

    Get PDF
    Abstract Aims: Therapy with an implantable cardioverter defibrillator (ICD) is established for the prevention of sudden cardiac death (SCD) in high risk patients. We aimed to determine the effectiveness of primary prevention ICD therapy by analysing registry data from 14 centres in 11 European countries compiled between 2002 and 2014, with emphasis on outcomes in women who have been underrepresented in all trials. Methods and results: Retrospective data of 14 local registries of primary prevention ICD implantations between 2002 and 2014 were compiled in a central database. Predefined primary outcome measures were overall mortality and first appropriate and first inappropriate shocks. A multivariable model enforcing a common hazard ratio for sex category across the centres, but allowing for centre-specific baseline hazards and centre specific effects of other covariates, was adjusted for age, the presence of ischaemic cardiomyopathy or a CRT-D, and left ventricular ejection fraction ≤25%. Of the 5033 patients, 957 (19%) were women. During a median follow-up of 33 months (IQR 16–55 months) 129 women (13%) and 807 men (20%) died (HR 0.65; 95% CI: [0.53, 0.79], P-value &lt; 0.0001). An appropriate ICD shock occurred in 66 women (8%) and 514 men (14%; HR 0.61; 95% CI: 0.47–0.79; P = 0.0002). Conclusion: Our retrospective analysis of 14 local registries in 11 European countries demonstrates that fewer women than men undergo ICD implantation for primary prevention. After multivariate adjustment, women have a significantly lower mortality and receive fewer appropriate ICD shocks