97 research outputs found
Single-shot multi-slice T1 mapping at high spatial resolution â Inversion-recovery FLASH with radial undersampling and iterative reconstruction.
Purpose: To develop a method for T1 mapping at high spatial resolution and for multiple slices. Methods: The proposed method emerges as a single-shot inversion-recovery experiment which covers the entire spinlattice relaxation process by serial acquisitions of highly undersampled radial FLASH images, either in single-slice or multi-slice mode. Serial image reconstructions are performed in time-reversed order and first involve regularized nonlinear inversion (NLINV) to estimate optimum coil sensitivity profiles. Subsequently, the coil profiles are fixed for the calculation of differently T1-weighted frames and the resulting linear inverse problem is solved by a conjugate gradient (CG) technique. T1 values are obtained by pixelwise fitting with a Deichmann correction modified for multi-slice applications. Results: T1 accuracy was validated for a reference phantom. For human brain, T1 maps were obtained at 0.5 mm resolution for single-slice acquisitions and at 0.75 mm resolution for up to 5 simultaneous slices (5 mm thickness). Corresponding T1 maps of the liver were acquired at 1 mm and 1.5 mm resolution, respectively. All T1 values were in agreement with literature data. Conclusion: Inversion-recovery sequences with highly undersampled radial FLASH images and NLINV/CG reconstruction allow for fast, robust and accurate T1 mapping at high spatial resolution and for multiple slices
Real-time flow MRI of the aorta at a resolution of 40 msec.
PURPOSE: To evaluate a novel real-time phase-contrast magnetic resonance imaging (MRI) technique for the assessment of through-plane flow in the ascending aorta. MATERIALS AND METHODS: Real-time MRI was based on a radial fast low-angle shot (FLASH) sequence with about 30-fold undersampling and image reconstruction by regularized nonlinear inversion. Phase-contrast maps were obtained from two (interleaved or sequential) acquisitions with and without a bipolar velocity-encoding gradient. Blood flow in the ascending aorta was studied in 10 healthy volunteers at 3 T by both real-time MRI (15 sec during free breathing) and electrocardiogram (ECG)-synchronized cine MRI (with and without breath holding). Flow velocities and stroke volumes were evaluated using standard postprocessing software. RESULTS: The total acquisition time for a pair of phase-contrast images was 40.0 msec (TR/TE=2.86/1.93 msec, 10° flip angle, 7 spokes per image) for a nominal in-plane resolution of 1.3 mm and a section thickness of 6 mm. Quantitative evaluations of spatially averaged flow velocities and stroke volumes were comparable for real-time and cine methods when real-time MRI data were averaged across heartbeats. For individual heartbeats real-time phase-contrast MRI resulted in higher peak velocities for values above 120 cm s(-1) . CONCLUSION: Real-time phase-contrast MRI of blood flow in the human aorta yields functional parameters for individual heartbeats. When averaged across heartbeats real-time flow velocities and stroke volumes are comparable to values obtained by conventional cine MRI
Active laser frequency stabilization using neutral praseodymium (Pr)
We present a new possibility for the active frequency stabilization of a
laser using transitions in neutral praseodymium. Because of its five outer
electrons, this element shows a high density of energy levels leading to an
extremely line-rich excitation spectrum with more than 25000 known spectral
lines ranging from the UV to the infrared. We demonstrate the active frequency
stabilization of a diode laser on several praseodymium lines between 1105 and
1123 nm. The excitation signals were recorded in a hollow cathode lamp and
observed via laser-induced fluorescence. These signals are strong enough to
lock the diode laser onto most of the lines by using standard laser locking
techniques. In this way, the frequency drifts of the unlocked laser of more
than 30 MHz/h were eliminated and the laser frequency stabilized to within
1.4(1) MHz for averaging times >0.2 s. Frequency quadrupling the stabilized
diode laser can produce frequency-stable UV-light in the range from 276 to 281
nm. In particular, using a strong hyperfine component of the praseodymium
excitation line E = 16 502.616_7/2 cm^-1 -> E' = 25 442.742_9/2 cm^-1 at lambda
= 1118.5397(4) nm makes it possible - after frequency quadruplication - to
produce laser radiation at lambda/4 = 279.6349(1) nm, which can be used to
excite the D2 line in Mg^+.Comment: 10 pages, 14 figure
Flow cytometry as a rapid analytical tool to determine physiological responses to changing O2 and iron concentration by Magnetospirillum gryphiswaldense strain MSR-1
Magnetotactic bacteria (MTB) are a diverse group of bacteria that synthesise magnetosomes, magnetic membrane-bound nanoparticles that have a variety of diagnostic, clinical and biotechnological applications. We present the development of rapid methods using flow cytometry to characterize several aspects of the physiology of the commonly-used MTB Magnetospirillum gryphiswaldense MSR-1. Flow cytometry is an optical technique that rapidly measures characteristics of individual bacteria within a culture, thereby allowing determination of population heterogeneity and also permitting direct analysis of bacteria. Scatter measurements were used to measure and compare bacterial size, shape and morphology. Membrane permeability and polarization were measured using the dyes propidium iodide and bis-(1,3-dibutylbarbituric acid) trimethine oxonol to determine the viability and âhealthâ of bacteria. Dyes were also used to determine changes in concentration of intracellular free iron and polyhydroxylakanoate (PHA), a bacterial energy storage polymer. These tools were then used to characterize the responses of MTB to different O2 concentrations and iron-sufficient or iron-limited growth. Rapid analysis of MTB physiology will allow development of bioprocesses for the production of magnetosomes, and will increase understanding of this fascinating and useful group of bacteria
Equivalences of higher derived brackets
This note elaborates on Th. Voronovâs construction [Th. Voronov, Higher derived brackets and homotopy algebras, J. Pure Appl. Algebra 202 (1â3) (2005) 133â153; Th. Voronov, Higher derived brackets for arbitrary derivations, Travaux Math. XVI (2005) 163â186] of Lâ-structures via higher derived brackets with a MaurerâCartan element. It is shown that gauge equivalent MaurerâCartan elements induce Lâ-isomorphic structures. Applications in symplectic, Poisson and Dirac geometry are discussed
- âŠ