91 research outputs found
Poor accuracy of freehand cup positioning during total hip arthroplasty
Several studies have demonstrated a correlation between the acetabular cup position and the risk of dislocation, wear and range of motion after total hip arthroplasty. The present study was designed to evaluate the accuracy of the surgeon’s estimated position of the cup after freehand placement in total hip replacement. Peroperative estimated abduction and anteversion of 200 acetabular components (placed by three orthopaedic surgeons and nine residents) were compared with measured outcomes (according to Pradhan) on postoperative radiographs. Cups were placed in 49.7° (SD 6.7) of abduction and 16.0° (SD 8.1) of anteversion. Estimation of placement was 46.3° (SD 4.3) of abduction and 14.6° (SD 5.9) of anteversion. Of more interest is the fact that for the orthopaedic surgeons the mean inaccuracy of estimation was 4.1° (SD 3.9) for abduction and 5.2° (SD 4.5) for anteversion and for their residents this was respectively, 6.3° (SD 4.6) and 5.7° (SD 5.0). Significant differences were found between orthopaedic surgeons and residents for inaccuracy of estimation for abduction, not for anteversion. Body mass index, sex, (un)cemented fixation and surgical approach (anterolateral or posterolateral) were not significant factors. Based upon the inaccuracy of estimation, the group’s chance on future cup placement within Lewinnek’s safe zone (5–25° anteversion and 30–50° abduction) is 82.7 and 85.2% for anteversion and abduction separately. When both parameters are combined, the chance of accurate placement is only 70.5%. The chance of placement of the acetabular component within 5° of an intended position, for both abduction and anteversion is 21.5% this percentage decreases to just 2.9% when the tolerated error is 1°. There is a tendency to underestimate both abduction and anteversion. Orthopaedic surgeons are superior to their residents in estimating abduction of the acetabular component. The results of this study indicate that freehand placement of the acetabular component is not a reliable method
Analysis of Oxford medial unicompartmental knee replacement using the minimally invasive technique in patients aged 60 and above: an independent prospective series
We present the outcome of an independent prospective series of phase-3 Oxford medial mobile-bearing unicompartmental knee replacement surgery. Eight surgeons performed the 154 procedures in a community-based hospital between 1998 and 2003 for patients aged 60 and above. Seventeen knees were revised; in 14 cases a total knee replacement was performed, in 3 cases a component of the unicompartmental knee prosthesis was revised, resulting in a survival rate of 89% during these 2–7 years follow-up interval. This study shows that mobile-bearing unicompartmental knee replacement using a minimally invasive technique is a demanding procedure. The study emphasises the importance of routine in surgical management and strict adherence to indications and operation technique used to reduce outcome failure
Inappropriate use of the title 'chiropractor' and term 'chiropractic manipulation' in the peer-reviewed biomedical literature
BACKGROUND: The misuse of the title 'chiropractor' and term 'chiropractic manipulation', in relation to injury associated with cervical spine manipulation, have previously been reported in the peer-reviewed literature. The objectives of this study were to - 1) Prospectively monitor the peer-reviewed literature for papers reporting an association between chiropractic, or chiropractic manipulation, and injury; 2) Contact lead authors of papers that report such an association in order to determine the basis upon which the title 'chiropractor' and/or term 'chiropractic manipulation' was used; 3) Document the outcome of submission of letters to the editors of journals wherein the title 'chiropractor', and/or term 'chiropractic manipulation', had been misused and resulted in the over-reporting of chiropractic induced injury. METHODS: One electronic database (PubMed) was monitored prospectively, via monthly PubMed searches, during a 12 month period (June 2003 to May 2004). Once relevant papers were located, they were reviewed. If the qualifications and/or profession of the care provider/s were not apparent, an attempt was made to confirm them via direct e-mail communication with the principal researcher of each respective paper. A letter was then sent to the editor of each involved journal. RESULTS: A total of twenty four different cases, spread across six separate publications, were located via the monthly PubMed searches. All twenty four cases took place in one of two European countries. The six publications consisted of four case reports, each containing one patient, one case series, involving twenty relevant cases, and a secondary report that pertained to one of the four case reports. In each of the six publications the authors suggest the care provider was a chiropractor and that each patient received chiropractic manipulation of the cervical spine prior to developing symptoms suggestive of traumatic injury. In two of the four case reports contact with the principal researcher revealed that the care provider was not a chiropractor, as defined by the World Federation of Chiropractic. The authors of the other two case reports did not respond to my communications. In the case series, which involved twenty relevant cases, the principal researcher conceded that the term chiropractor had been inappropriately used and that his case series did not relate to chiropractors who had undergone appropriate formal training. The author of the secondary report, a British Medical Journal editor, conceded that he had misused the title chiropractor. Letters to editors were accepted and published by all four journals to which they were sent. To date one of the four journals has published a correction. CONCLUSION: The results of this year-long prospective review suggests that the words 'chiropractor' and 'chiropractic manipulation' are often used inappropriately by European biomedical researchers when reporting apparent associations between cervical spine manipulation and symptoms suggestive of traumatic injury. Furthermore, in those cases reported here, the spurious use of terminology seems to have passed through the peer-review process without correction. Additionally, these findings provide further preliminary evidence, beyond that already provided by Terrett, that the inappropriate use of the title 'chiropractor' and term 'chiropractic manipulation' may be a significant source of over-reporting of the link between the care provided by chiropractors and injury. Finally, editors of peer-reviewed journals were amenable to publishing 'letters to editors', and to a lesser extent 'corrections', when authors had inappropriately used the title 'chiropractor' and/or term 'chiropractic manipulation'
Navigated cup implantation in hip arthroplasty: A meta-analysis
Background and purpose Many studies have suggested that navigation-based implantation can improve cup positioning in total hip arthroplasty (THA). We conducted a systematic review and meta-analysis to compile the best available evidence, and to overcome potential shortcomings because of small sample sizes in individual studies
Calcitonin substitution in calcitonin deficiency reduces particle-induced osteolysis
<p>Abstract</p> <p>Background</p> <p>Periprosthetic osteolysis is a major cause of aseptic loosening in joint arthroplasty. This study investigates the impact of CT (calcitonin) deficiency and CT substitution under in-vivo circumstances on particle-induced osteolysis in <it>Calca </it>-/- mice.</p> <p>Methods</p> <p>We used the murine calvarial osteolysis model based on ultra-high molecular weight polyethylene (UHMWPE) particles in 10 C57BL/6J wild-type (WT) mice and twenty <it>Calca </it>-/- mice. The mice were divided into six groups: WT without UHMWPE particles (Group 1), WT with UHMWPE particles (Group 2), <it>Calca </it>-/- mice without UHMWPE particles (Group 3), <it>Calca </it>-/- mice with UHMWPE particles (Group 4), <it>Calca </it>-/- mice without UHMWPE particles and calcitonin substitution (Group 5), and <it>Calca </it>-/- mice with UHMWPE particle implantation and calcitonin substitution (Group 6). Analytes were extracted from serum and urine. Bone resorption was measured by bone histomorphometry. The number of osteoclasts was determined by counting the tartrate-resistant acid phosphatase (TRACP) + cells.</p> <p>Results</p> <p>Bone resorption was significantly increased in <it>Calca </it>-/- mice compared with their corresponding WT. The eroded surface in <it>Calca </it>-/- mice with particle implantation was reduced by 20.6% after CT substitution. Osteoclast numbers were significantly increased in <it>Calca </it>-/- mice after particle implantation. Serum OPG (osteoprotegerin) increased significantly after CT substitution.</p> <p>Conclusions</p> <p>As anticipated, <it>Calca </it>-/- mice show extensive osteolysis compared with wild-type mice, and CT substitution reduces particle-induced osteolysis.</p
The effect of intra-articular botulinum toxin A on substance P, prostaglandin E-2, and tumor necrosis factor alpha in the canine osteoarthritic joint
Background: Recently, intra-articular botulinum toxin A (IA BoNT A) has been shown to reduce joint pain in osteoarthritic dogs. Similar results have been reported in human patients with arthritis. However, the mechanism of the antinociceptive action of IA BoNT A is currently not known. The aim of this study was to explore this mechanism of action by investigating the effect of IA BoNT A on synovial fluid (SF) and serum substance P (SP), prostaglandin E-2 (PGE(2)), and tumor necrosis factor alpha (TNF-alpha) in osteoarthritic dogs. Additionally, the aim was to compare SF SP and PGE(2) between osteoarthritic and non-osteoarthritic joints, and investigate associations between SP, PGE(2), osteoarthritic pain, and the signalment of dogs. Thirty-five dogs with chronic naturally occurring osteoarthritis and 13 non-osteoarthritic control dogs were included in the study. Osteoarthritic dogs received either IA BoNT A (n = 19) or IA placebo (n = 16). Serum and SF samples were collected and osteoarthritic pain was evaluated before (baseline) and 2 and 8 weeks after treatment. Osteoarthritic pain was assessed with force platform, Helsinki Chronic Pain Index, and joint palpation. Synovial fluid samples were obtained from control dogs after euthanasia. The change from baseline in SP and PGE(2) concentration was compared between the IA BoNT A and placebo groups. The synovial fluid SP and PGE(2) concentration was compared between osteoarthritic and control joints. Associations between SP, PGE(2), osteoarthritic pain, and the signalment of dogs were evaluated. Results: There was no significant change from baseline in SP or PGE(2) after IA BoNT A. Synovial fluid PGE(2) was significantly higher in osteoarthritic compared to control joints. Synovial fluid PGE(2) correlated with osteoarthritic pain. No associations were found between SP or PGE2 and the signalment of dogs. The concentration of TNF-alpha remained under the detection limit of the assay in all samples. Conclusions: The results suggest that the antinociceptive effect of IA BoNT A in the joint might not be related to the inhibition of SP nor PGE(2). Synovial fluid PGE(2,) but not SP, could be a marker for chronic osteoarthritis and pain in dogs.Peer reviewe
Osteochondral defects in the ankle: why painful?
Osteochondral defects of the ankle can either heal and remain asymptomatic or progress to deep ankle pain on weight bearing and formation of subchondral bone cysts. The development of a symptomatic OD depends on various factors, including the damage and insufficient repair of the subchondral bone plate. The ankle joint has a high congruency. During loading, compressed cartilage forces its water into the microfractured subchondral bone, leading to a localized high increased flow and pressure of fluid in the subchondral bone. This will result in local osteolysis and can explain the slow development of a subchondral cyst. The pain does not arise from the cartilage lesion, but is most probably caused by repetitive high fluid pressure during walking, which results in stimulation of the highly innervated subchondral bone underneath the cartilage defect. Understanding the natural history of osteochondral defects could lead to the development of strategies for preventing progressive joint damage
- …