60 research outputs found

    Spotlight on MicroPulse laser trabeculoplasty in open-angle glaucoma: What's on? A eeview of the literature

    Get PDF
    Glaucoma is the most common cause of permanent blindness in the world, caused by a progressive optic neuropathy. Patients with glaucoma are often treated with topical medicines therapy in order to reduce intra-ocular pressure (IOP). On the other hand, laser therapies, with the introduction of Argon Laser Trabeculoplasty (ALT) and successively with Selective Laser Trabeculoplasty (SLT), were reported to be effective in IOP control, with low adverse effect rates. In recent years, the micropulse laser, a subthreshold laser technology, was introduced with the goal of reducing side effects while maintaining the effectiveness of the laser treatments. Several studies focused on Micropulse Diode Laser Trabeculoplasty (MDLT) in open-angle glaucoma, to evaluate its effectiveness and possible side effects. Promising results were reported, but irradiation circumstances have not been standardized yet and its role as a substitute for previous laser techniques has yet to be defined. As a result, the goal of this review was to analyze the physical principles at the basis of MDLT and to frame it in the open-angle glaucoma management setting, highlighting the advantages and shortfalls of this technique

    Bariatric surgery and diabetes remission: Sleeve gastrectomy or mini-gastric bypass?

    Get PDF
    AIM: To investigate the weight loss and glycemic control status [blood glucose, hemoglobin A1c (HbA1c) and hypoglycaemic treatment]. METHODS: The primary risk factor for type 2 diabetes is obesity, and 90% of all patients with type 2 diabetes are overweight or obese. Although a remarkable effect of bariatric surgery is the profound and durable resolution of type 2 diabetes clinical manifestations, little is known about the difference among various weight loss surgical procedures on diabetes remission. Data from patients referred during a 3-year period (from January 2009 to December 2011) to the University of Naples "Federico II" diagnosed with obesity and diabetes were retrieved from a prospective database. The patients were split into two groups according to the surgical intervention performed [sleeve gastrectomy (SG) and mini-gastric bypass (MGB)]. Weight loss and glycemic control status (blood glucose, HbA1c and hypoglycaemic treatment) were evaluated. RESULTS: A total of 53 subjects who underwent sleeve gastrectomy or mini-gastric bypass for obesity and diabetes were screened for the inclusion in this study. Of these, 4 subjects were excluded because of surgical complications, 7 subjects were omitted because young surgeons conducted the operations and 11 subjects were removed because of the lack of follow-up. Thirty-one obese patients were recruited for this study. A total of 15 subjects underwent SG (48.4%), and 16 underwent MGB (51.6%). After adjusting for various clinical and demographic characteristics in a multivariate logistic regression analysis, high hemoglobin A1c was determined to be a negative predictor of diabetes remission at 12 mo (OR = 0.366, 95%CI: 0.152-0.884). Using the same regression model, MGB showed a clear trend toward higher diabetes remission rates relative to SG (OR = 3.780, 95%CI: 0.961-14.872). CONCLUSION: Although our results are encouraging regarding the effectiveness of mini-gastric bypass on diabetes remission, further studies are needed to provide definitive conclusions in selecting the ideal procedure for diabetes remission

    PreserFlo® MicroShunt: an overview of this minimally invasive device for open-angle glaucoma

    Get PDF
    For moderate-to-severe glaucoma, trabeculectomy remains the “gold standard” intraocular pressure (IOP)-lowering treatment; nonetheless, this method requires extensive post-operative maintenance. Microinvasive glaucoma surgery (MIGS) treatments are designed to lessen intra- and post-operative care burden while offering an acceptable IOP decrease for individuals with mild to moderate glaucoma. The PreserFlo® MicroShunt (previously InnFocus MicroShunt) is an 8.5 mm glaucoma drainage device manufactured from poly(styrene-block-isobutylene-block-styrene) (SIBS), an extremely biocompatible and bioinert material. The lumen is narrow enough to prevent hypotony, but big enough to avoid being obstructed by sloughed cells or pigment. The device is implanted ab externo, as a stand-alone procedure or in conjunction with cataract surgery, with intraoperative mitomycin C, and a bleb is produced under the conjunctiva and Tenon’s capsule. The MicroShunt was CE-marked in 2012 and designed for primary open-angle glaucoma, the IOP of which remains uncontrolled after maximally tolerated topical treatment. Several clinical trials evaluating the MicroShunt’s long-term safety and effectiveness have been conducted, highlighting the effectiveness of the device over time, along with a tolerable safety profile. The present review aims to gather evidence of PreserFlo’s effectiveness and safety results almost 10 years after its introduction, and furthermore, to compare it with other MIGS and with the gold-standard trabeculectomy for glaucoma management

    Overview on defocus incorporated multiple segments lenses: a novel perspective in myopia progression management

    Get PDF
    Myopia is becoming more common across the world, affecting approximately two billion people and rising. Different kinds of therapies (optical, pharmaceutical, environmental, or behavioral) have been proposed to decrease myopia progression, but with variable results and a lack of standardization. The evidence that targeted myopic defocus inhibits eye length growth has paved the way for several contact and spectacle lense designs to induce a peripheral defocus, thus slowing myopia progression, but the perfect configuration has yet to be defined. One of the newest and more promising approaches in this field is the use of Defocus Incorporated Multiple Segments (DIMS) lenses. These lenses are built from the assumption that targeted myopic defocus, produced by 396 mid-peripheral lenslets with positive power, inhibits eye length growth. Recent studies have highlighted the effectiveness of these lenses compared to children who had worn single vision spectacle lenses, in terms of myopia control and tolerability. Despite the evidence that these lenses can help slow down the progression of myopia, the occasional mid-peripheral aberrations they can induce, as well as the overall eye strain that comes with wearing them, should not be overlooked. The aim of this review is to give attention to the advantages and the shortfalls of this new approach and to evaluate its effectiveness in clinical practice

    Anterior Segment-Optical Coherence Tomography Bleb Morphology Comparison in Minimally Invasive Glaucoma Surgery: XEN Gel Stent vs. PreserFlo MicroShunt

    Get PDF
    Background: The purpose of this study is to compare the morphology of six-month follow-up blebs created by a subconjunctival glaucoma surgical device (XEN45) to those created by a PreserFlo MicroShunt with a sub-Tenon insertion, utilizing AS-OCT. Methods: A retrospective study of 29 eyes who underwent XEN45 implantation and 29 eyes who underwent PreserFlo MicroShunt implantation. The patients were analyzed at 24 h, 1 week, 1 month, 3 months and 6 months. At each visit, the maturation and morphological alterations of the blebs were observed, as well as connections with the IOP. Results: In both groups, IOP showed significant reduction at all follow ups (p < 0.0001). In XEN group, the most common bleb morphology in the immediate postoperative was the subconjuntival separation type (42%) followed by the uniform type (34%), with a trend inversion at 6 month follow up (51% of uniform type). On the contrary, the most common morphology after PreserFlo was the multiple internal layer (55%), which showed a tendency to reduce over time and was substituted by the microcystic multiform, whose percentage increased over time (17% at day 1 vs. 44% at month 6). Uniform appearance was associated by the posterior episcleral fluid (PEF) lake presence. Both horizontal and vertical diameters significantly increased over time. Conclusion: XEN and PreserFlo implantation resulted in the production of diffuse blebs with different characteristics, which may influence IOP lowering capacity and bleb revisions necessity over time

    COVID-19 atypical Parsonage-Turner syndrome: a case report

    Get PDF
    Background Neurological manifestations of Sars-CoV-2 infection have been described since March 2020 and include both central and peripheral nervous system manifestations. Neurological symptoms, such as headache or persistent loss of smell and taste, have also been documented in COVID-19 long-haulers. Moreover, long lasting fatigue, mild cognitive impairment and sleep disorders appear to be frequent long term neurological manifestations after hospitalization due to COVID-19. Less is known in relation to peripheral nerve injury related to Sars-CoV-2 infection. Case presentation We report the case of a 47-year-old female presenting with a unilateral chest pain radiating to the left arm lasting for more than two months after recovery from Sars-CoV-2 infection. After referral to our post-acute outpatient service for COVID-19 long haulers, she was diagnosed with a unilateral, atypical, pure sensory brachial plexus neuritis potentially related to COVID-19, which occurred during the acute phase of a mild Sars-CoV-2 infection and persisted for months after resolution of the infection. Conclusions We presented a case of atypical Parsonage-Turner syndrome potentially triggered by Sars-CoV-2 infection, with symptoms and repercussion lasting after viral clearance. A direct involvement of the virus remains uncertain, and the physiopathology is unclear. The treatment of COVID-19 and its long-term consequences represents a relatively new challenge for clinicians and health care providers. A multidisciplinary approach to following-up COVID-19 survivors is strongly advised
    • …
    corecore