49 research outputs found

    Impact of the COVID-19 pandemic on ophthalmologic outpatient care: experience from an Italian Tertiary Medical Center

    Get PDF
    Purpose: To evaluate the impact the COVID-19-related national lockdown has had on Ophthalmologic Outpatient Care in an Italian Tertiary Medical Centre. Methods: We reviewed all the performances that were carried out as outpatient services at our department between 1 January 2020 and 30 November 2020. We compared data among four different periods: from 1 January 2020 to 17 March 2020 ("Pre-Lockdown"); from 18 March 2020 to 17 May 2020 (Lockdown); from 18 May 2020 to 2 November 2020 (Post-Lockdown) and from 3 November 2020 to 30 November 2020 (Regional Lockdown). Results: The overall number of performed routine outpatient visits per day (ROVs) was 11,871 (Mean \ub1 SD = 35.76 \ub1 17.81), whereas booked appointments (BAs) were 21272 (Mean \ub1 SD = 63.86 \ub1 9.27), meaning a decline in the number of ROVs by 44.01%. (Mean \ub1 SD = 28.10 \ub1 12.11, p<.001). Post-Lockdown and Regional Lockdown clinical activities, dropped respectively by 31 and 25.14% (38.87 \ub1 3.88 vs. 56.34 \ub1 11.06, p<.001 and 6.04 \ub1 4.51 vs. 56.34 \ub1 11.06 p<.001). The number of BAs per day decreased during the pandemic, going from a mean of 77.81 \ub1 2.57 booked appointments per day before the lockdown, to a mean of 53.14 \ub1 4.94, 61.80 \ub1 4.62 and 72.07 \ub1 1.09 appointments per day respectively during the lockdown, the post-lockdown and the regional lockdown periods. Conclusions: During the various lockdown periods, at our institution the volume of outpatient ophthalmological visits drastically dropped. This testifies the dramatic impact the COVID-19 pandemic has had on the supply of ophthalmic care

    Spotlight on MicroPulse laser trabeculoplasty in open-angle glaucoma: What's on? A eeview of the literature

    Get PDF
    Glaucoma is the most common cause of permanent blindness in the world, caused by a progressive optic neuropathy. Patients with glaucoma are often treated with topical medicines therapy in order to reduce intra-ocular pressure (IOP). On the other hand, laser therapies, with the introduction of Argon Laser Trabeculoplasty (ALT) and successively with Selective Laser Trabeculoplasty (SLT), were reported to be effective in IOP control, with low adverse effect rates. In recent years, the micropulse laser, a subthreshold laser technology, was introduced with the goal of reducing side effects while maintaining the effectiveness of the laser treatments. Several studies focused on Micropulse Diode Laser Trabeculoplasty (MDLT) in open-angle glaucoma, to evaluate its effectiveness and possible side effects. Promising results were reported, but irradiation circumstances have not been standardized yet and its role as a substitute for previous laser techniques has yet to be defined. As a result, the goal of this review was to analyze the physical principles at the basis of MDLT and to frame it in the open-angle glaucoma management setting, highlighting the advantages and shortfalls of this technique

    Morpho-Functional Evaluation of Full-Thickness Macular Holes by the Integration of Optical Coherence Tomography Angiography and Microperimetry

    Get PDF
    (1) Objective: To use optical coherence tomography angiography (OCTA) and microperimetry (MP) to evaluate the correlation between retinal structure and function in patients with idiopathic, full-thickness macular holes (FTMHs) (2) Methods: This prospective, observational study included 11 eyes of 10 patients with FTMHs evaluated before surgery using OCTA and MP. MP sensitivity maps were superimposed and registered on slabs corresponding to superficial capillary plexus (SCP) and deep capillary plexus (DCP) on OCTA, and on the outer plexiform layer (OPL) and the Henle fiber layer (HFL) complex in en face OCT. On these maps, mean retinal sensitivity was calculated at 2 degrees and 4 degrees, all centered on the FTMH. Cystic cavity extension was assessed on the slab corresponding to the OPL + HFL complex in en face OCT and DCP in OCTA using the Image J software (Version 1.49v; National Institutes of Health, Bethesda, MD, USA); (3) Results: Absolute scotomas were observed corresponding to the FTMH. Additionally, rings of relative scotoma in the perilesional area were detected and correlated to the cystic spaces on en face OCT and OCTA. There was a significant correlation between reduced retinal sensitivity at 2 degrees and 4 degrees diameters around the FTMH and the extension of cystic areas (p < 0.01). There was a significant correlation between the extension of cystic cavities and BCVA (p < 0.01). (4) Conclusions: Morpho-functional analysis of FTMH using OCTA and MP, and the correlation between vascular abnormalities and impaired retinal sensitivity, may provide new, useful information. This integrated evaluation of FTMH may be useful to determine the function-structure correlation before and after vitreoretinal surgery, in order to gain a better understanding of the functional consequences induced by the morphological alterations, assessing outcomes in a more objective way, and potentially adding new surgical prognostic factors

    PreserFlo® MicroShunt: an overview of this minimally invasive device for open-angle glaucoma

    Get PDF
    For moderate-to-severe glaucoma, trabeculectomy remains the “gold standard” intraocular pressure (IOP)-lowering treatment; nonetheless, this method requires extensive post-operative maintenance. Microinvasive glaucoma surgery (MIGS) treatments are designed to lessen intra- and post-operative care burden while offering an acceptable IOP decrease for individuals with mild to moderate glaucoma. The PreserFlo® MicroShunt (previously InnFocus MicroShunt) is an 8.5 mm glaucoma drainage device manufactured from poly(styrene-block-isobutylene-block-styrene) (SIBS), an extremely biocompatible and bioinert material. The lumen is narrow enough to prevent hypotony, but big enough to avoid being obstructed by sloughed cells or pigment. The device is implanted ab externo, as a stand-alone procedure or in conjunction with cataract surgery, with intraoperative mitomycin C, and a bleb is produced under the conjunctiva and Tenon’s capsule. The MicroShunt was CE-marked in 2012 and designed for primary open-angle glaucoma, the IOP of which remains uncontrolled after maximally tolerated topical treatment. Several clinical trials evaluating the MicroShunt’s long-term safety and effectiveness have been conducted, highlighting the effectiveness of the device over time, along with a tolerable safety profile. The present review aims to gather evidence of PreserFlo’s effectiveness and safety results almost 10 years after its introduction, and furthermore, to compare it with other MIGS and with the gold-standard trabeculectomy for glaucoma management

    Overview on defocus incorporated multiple segments lenses: a novel perspective in myopia progression management

    Get PDF
    Myopia is becoming more common across the world, affecting approximately two billion people and rising. Different kinds of therapies (optical, pharmaceutical, environmental, or behavioral) have been proposed to decrease myopia progression, but with variable results and a lack of standardization. The evidence that targeted myopic defocus inhibits eye length growth has paved the way for several contact and spectacle lense designs to induce a peripheral defocus, thus slowing myopia progression, but the perfect configuration has yet to be defined. One of the newest and more promising approaches in this field is the use of Defocus Incorporated Multiple Segments (DIMS) lenses. These lenses are built from the assumption that targeted myopic defocus, produced by 396 mid-peripheral lenslets with positive power, inhibits eye length growth. Recent studies have highlighted the effectiveness of these lenses compared to children who had worn single vision spectacle lenses, in terms of myopia control and tolerability. Despite the evidence that these lenses can help slow down the progression of myopia, the occasional mid-peripheral aberrations they can induce, as well as the overall eye strain that comes with wearing them, should not be overlooked. The aim of this review is to give attention to the advantages and the shortfalls of this new approach and to evaluate its effectiveness in clinical practice

    Retinal Pigment Epithelial and Outer Retinal Atrophy in Age-Related Macular Degeneration: Correlation with Macular Function

    Get PDF
    The purpose of this study was to investigate the relationship between the retinal pigment epithelium (RPE) and outer retina changes, expressed in terms of sub-RPE illumination (SRI) on optical-coherence tomography (OCT), and central retinal function, measured by visual acuity and focal electroretinogram (fERG), in patients with non-exudative age-related macular degeneration (neAMD). In this retrospective study, 29 eyes of 29 patients affected by early (24.14%), intermediate (41.38%), and advanced (34.48%) neAMD were evaluated. All enrolled eyes were studied with OCT to measure the total area of SRI, by using an automated standardized algorithm. Visual acuity and fERG were assessed. The area of SRI was negatively correlated with fERG amplitude (r <= -0.4, p <= 0.02) and best-corrected visual acuity (BCVA) (r <= 0.4, p <= 0.04). Our results indicate that the severity of retinal pigment epithelium and outer retina atrophy (RORA), indirectly quantified through the detection of SRI areas by commercial OCT algorithms, is correlated with central retinal dysfunction, as determined by visual acuity and fERG, supporting the combined use of structural exams and functional tests as valid tools to detect the extent of RPE and photoreceptors' disruption

    Anterior Segment-Optical Coherence Tomography Bleb Morphology Comparison in Minimally Invasive Glaucoma Surgery: XEN Gel Stent vs. PreserFlo MicroShunt

    Get PDF
    Background: The purpose of this study is to compare the morphology of six-month follow-up blebs created by a subconjunctival glaucoma surgical device (XEN45) to those created by a PreserFlo MicroShunt with a sub-Tenon insertion, utilizing AS-OCT. Methods: A retrospective study of 29 eyes who underwent XEN45 implantation and 29 eyes who underwent PreserFlo MicroShunt implantation. The patients were analyzed at 24 h, 1 week, 1 month, 3 months and 6 months. At each visit, the maturation and morphological alterations of the blebs were observed, as well as connections with the IOP. Results: In both groups, IOP showed significant reduction at all follow ups (p < 0.0001). In XEN group, the most common bleb morphology in the immediate postoperative was the subconjuntival separation type (42%) followed by the uniform type (34%), with a trend inversion at 6 month follow up (51% of uniform type). On the contrary, the most common morphology after PreserFlo was the multiple internal layer (55%), which showed a tendency to reduce over time and was substituted by the microcystic multiform, whose percentage increased over time (17% at day 1 vs. 44% at month 6). Uniform appearance was associated by the posterior episcleral fluid (PEF) lake presence. Both horizontal and vertical diameters significantly increased over time. Conclusion: XEN and PreserFlo implantation resulted in the production of diffuse blebs with different characteristics, which may influence IOP lowering capacity and bleb revisions necessity over time

    Internal Tube Occlusion with An Easily Removable Non-Absorbable Double Suture: A Novel Surgical Technique Adjunct for Non-Valved Glaucoma Drainage Devices

    No full text
    To describe a surgical variant for non-valved glaucoma drainage device implants using an easily removable non-absorbable double suture into the lumen of the tube. A retrospective, non-comparative case series of 10 patients who underwent a non-valved glaucoma drainage device implant with an endoluminal double-suture for refractory glaucoma. The sutures were easily removed postoperatively without the need for an operating room. Intraocular pressure, number of medications, and early and late complications were evaluated with a follow-up of 12 months. None of the eyes that underwent an operation developed early or late complications. The first endoluminal suture was removed in all eyes with a mean time of removal of 30 ± 7 days. The second suture was removed in all eyes with a mean time of removal of 90 ± 7 days. No complications were noted, either, after or during suture removal. The mean preoperative IOP was 27.3 ± 4.0 and the postoperative IOP, at the end of the follow-up, was 12.7 ± 1.4. At the end of the follow-up, six patients (60%) achieved complete success and four patients (40%) achieved qualified success. In conclusion, in our case series, the surgical variant allowed for a safe and gradual regulation of the flow during postoperative management. Considering the efficacy of non-valved glaucoma drainage devices, an improvement in the safety profile allows surgeons to broaden the surgical indications

    Bilateral Glaucomatous Optic Neuropathy Caused by Eye Rubbing

    No full text
    In this report, we describe a particular condition of a 52-year-old man who showed advanced bilateral glaucomatous-like optic disc damage, even though the intraocular pressure resulted normal during all examinations performed. Visual field test, steady-state pattern electroretinogram, retinal nerve fiber layer and retinal tomographic evaluations were performed to evaluate the optic disc damage. Over a 4-year observational period, his visual acuity decreased to 12/20 in the right eye and counting fingers in the left eye. Visual fields were severely compromised, and intraocular pressure values were not superior to 14 mm Hg during routine examinations. An accurate anamnesis and the suspicion of this disease represent a crucial aspect to establish the correct diagnosis. In fact, our patient strongly rubbed his eyes for more than 10 h per day. Recurrent and continuous eye rubbing can induce progressive optic neuropathy, causing severe visual field damage similar to the pathology of advanced glaucoma
    corecore