56 research outputs found

    Computerized Microtomography in Scanning Electron Microscopy

    Get PDF
    Non-destructive methods of inner object structure reconstruction in the scanning electron microscope (SEM) have been studied. For specimens with a size of about 1 mm a spatial resolution of 10 μm has been achieved. The reconstruction is made from a project ion in X-ray radiation. Algorithms of conventional computerized tomography are used. The application of 3-dimensional reconstruction to different types of microobjects has been shown. As an example, microtomography of organic objects (grass grain, beetle head) and inorganic objects (semiconductor diode) has been carried out

    Processing of Scanning Electron Microscope Images on Basis of Fast Fourier-Transformation

    Get PDF
    The solar cell as a combined substrate and detector was used for automated SEM-image analysis. It was noted that an image processing system was created and its operational features are shown in some typical applications. The step size of the fatigue striations was found. The obtained value of the step corresponds to the formula with an accuracy of about 1 per cent. Quantum-mechanical constant of material fracture for aluminum alloys was found to be = 0.22. Two-dimensional periodic analysis was applied to fracture surfaces and a microchannel plate. The integral characteristics of microstructure was determined quantitatively

    Monte Carlo study of the effects of system geometry and antiscatter grids on cone-beam CT scatter distributions

    Get PDF
    Purpose: The proliferation of cone-beam CT (CBCT) has created interest in performance optimization,with x-ray scatter identifie among the main limitations to image quality. CBCT often contends with elevated scatter, but the wide variety of imaging geometry in different CBCT configuration suggests that not all configuration are affected to the same extent. Graphics processing unit (GPU) accelerated Monte Carlo (MC) simulations are employed over a range of imaging geometries to elucidate the factors governing scatter characteristics, effica y of antiscatter grids, guide system design, and augment development of scatter correction. Methods: A MC x-ray simulator implemented on GPU was accelerated by inclusion of variance reduction techniques (interaction splitting, forced scattering, and forced detection) and extended to include x-ray spectra and analytical models of antiscatter grids and flat-pane detectors. The simulator was applied to small animal (SA), musculoskeletal (MSK) extremity, otolaryngology (Head), breast, interventional C-arm, and on-board (kilovoltage) linear accelerator (Linac) imaging, with an axis-todetector distance (ADD) of 5, 12, 22, 32, 60, and 50 cm, respectively. Each configuratio was modeled with and without an antiscatter grid and with (i) an elliptical cylinder varying 70–280 mm in major axis; and (ii) digital murine and anthropomorphic models. The effects of scatter were evaluated in terms of the angular distribution of scatter incident upon the detector, scatter-to-primary ratio (SPR), artifact magnitude, contrast, contrast-to-noise ratio (CNR), and visual assessment. Results: Variance reduction yielded improvements in MC simulation efficien y ranging from ∼17-fold (for SA CBCT) to ∼35-fold (for Head and C-arm), with the most significan acceleration due to interaction splitting (∼6 to ∼10-fold increase in efficien y). The benefi of a more extended geometry was evident by virtue of a larger air gap—e.g., for a 16 cm diameter object, the SPR reduced from 1.5 for ADD = 12 cm (MSK geometry) to 1.1 for ADD = 22 cm (Head) and to 0.5 for ADD = 60 cm (C-arm). Grid efficien y was higher for configuration with shorter air gap due to a broader angular distribution of scattered photons—e.g., scatter rejection factor ∼0.8 for MSK geometry versus ∼0.65 for C-arm. Grids reduced cupping for all configuration but had limited improvement on scatterinduced streaks and resulted in a loss of CNR for the SA, Breast, and C-arm. Relative contribution of forward-directed scatter increased with a grid (e.g., Rayleigh scatter fraction increasing from ∼0.15 without a grid to ∼0.25 with a grid for the MSK configuration) resulting in scatter distributions with greater spatial variation (the form of which depended on grid orientation). Conclusions: A fast MC simulator combining GPU acceleration with variance reduction provided a systematic examination of a range of CBCT configuration in relation to scatter, highlighting the magnitude and spatial uniformity of individual scatter components, illustrating tradeoffs in CNR and artifacts and identifying the system geometries for which grids are more beneficia (e.g., MSK) from those in which an extended geometry is the better defense (e.g., C-arm head imaging). Compact geometries with an antiscatter grid challenge assumptions of slowly varying scatter distributions due to increased contribution of Rayleigh scatter.The research was supported by academic-industry partnership with Carestream Health Inc. (Rochester, NY) and National Institutes of Health (NIH) Grant No. 2R01-CA-112163. A. Sisniega is supported by FPU grant (Spanish Ministry of Education), AMIT project, RECAVA-RETIC Network, Project Nos. TEC2010-21619- C04-01, TEC2011-28972-C02-01, and PI11/00616 (Spanish Ministry of Science and Education), ARTEMIS program (Comunidad de Madrid), and PreDiCT-TB partnership.Publicad

    D103 Laboratory System for X-ray Nanotomography

    No full text

    >

    No full text

    >

    No full text
    • …
    corecore