230 research outputs found

    Silicone migration to the contralateral axillary lymph nodes and breast after highly cohesive silicone gel implant failure: a case report

    Get PDF
    Highly cohesive silicone gel implants are advertised for aesthetic and safety advantages. Our case is the fourth report describing early implant rupture and contralateral migration of siliconoma. Despite the greater degree of gel cohesiveness, a continued vigilance for signs and symptoms of migration is highly recommended

    Dynamical control of quantum state transfer within hybrid open systems

    Full text link
    We analyze quantum state-transfer optimization within hybrid open systems, from a "noisy" (write-in) qubit to its "quiet" counterpart (storage qubit). Intriguing interplay is revealed between our ability to avoid bath-induced errors that profoundly depend on the bath-memory time and the limitations imposed by leakage out of the operational subspace. Counterintuitively, under no circumstances is the fastest transfer optimal (for a given transfer energy)

    The Periotest Method: Implant-Supported Framework Precision of Fit Evaluation

    Full text link
    : In this study, the Periotest instrument was used to measure the precision of fit between cast high noble-metal frameworks and the supporting implants in a patient-simulation model. Three framework conditions and three implant-location variables were used to evaluate the rigidity of the assembly as measured by the Periotest method. The framework variables were (1) one-piece castings (OPC); (2) sectioned-soldered inaccurate castings (SSIC); and (3) sectioned-soldered accurate castings (SSAC). The implant-location variables were right anterior (RA), center (C), and left anterior (LA). Materials and Methods : The patient simulation model used consisted of three self-tapping BrÅnemark implants in a reasonable arch curvature in bovine bone. Three working casts were fabricated from the patient-simulation model using polyvinyl siloxane and tapered impression copings. From the working casts, three sets of three frameworks were fabricated as OPCs, SSICs, and SSACs using type 3 high noble alloy. The SSICs were fabricated with a quantitative misfit of 101.6 Μm at the facial surface, between the abutment-to-gold cylinder interface at the C implant location. Periotest value (PTV) measurements were made at the midfacial surface of the frameworks directly above each abutment-to-gold cylinder interface. Three measurements were made for each test condition. The data were analyzed to compare framework condition(s) and implant location(s) using ANOVA and Fisher's Protected Least Significant Difference Comparison Test. Results : The ANOVA showed that significant differences exist between the mean PTV data for framework condition and for implant location (p < .01). Significant differences were shown between the mean PTV data for the SSAC assemblies and the OPC and SSIC assemblies. The SSICs displayed a more positive (+) mean PTV than the OPCs. The OPC assemblies had a more positive mean PTV than the SSAC assemblies. The mean PTV data for the SSAC assemblies had a significantly different PTV (p < .01) than the other two framework condition assemblies. The OPC and the SSIC assemblies had PTVs that were not significantly different. The C implant location was significantly different from the RA and the LA implant locations (p < .01). The RA and the LA implant locations were not significantly different from each other. The C implant location always demonstrated the most positive mean PTV regardless of the framework condition being tested. Conclusions : The Periotest instrument quantified differences in the precision of fit between three framework conditions. The SSAC assemblies were significantly more rigid than the OPC and SSIC assemblies. The OPC and SSIC assemblies' mean PTVs were not significantly different. The mean PTVs for the C implant location and the RA and LA implant locations were significantly different (p < .01). The mean PTVs of the RA and LA implant locations were not significantly different. The implant-location PTVs followed the same rank order for all three framework conditions. The procedures used to fabricate a more precise fit between the framework and the supporting implants is influenced by the skill of the clinician and technician.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/75096/1/j.1532-849X.1996.tb00298.x.pd

    Human Rights and the Pink Tide in Latin America : Which Rights Matter?

    Get PDF
    Latin America witnessed the election of ‘new Left’ governments in the early 21 st century that, in different ways, sought to open a debate about alternatives to paradigms of neoliberal development. What has this meant for the way that human rights are understood and for patterns of human rights compliance? Using qualitative and quantitative evidence, this article discusses how human rights are imagined and the compliance records of new Left governments through the lens of the three ‘generations’ of human rights — political and civil, social and economic, and cultural and environmental rights. The authors draw in particular on evidence from Andean countries and the Southern Cone. While basic civil and individual liberties are still far from guaranteed, especially in the Andean region, new Left countries show better overall performances in relation to socio-economic rights compared to the past and to other Latin American countries. All new Left governments also demonstrate an increasing interest in ‘third generation’ (cultural and environmental) rights, though this is especially marked in the Andean Left. The authors discuss the tensions around interpretations and categories of human rights, reflect on the stagnation of first generation rights and note the difficulties associated with translating second and third generation rights into policy

    Use of hospitalisation history (lookback) to determine prevalence of chronic diseases: impact on modelling of risk factors for haemorrhage in pregnancy

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Concern about the completeness of comorbidity information in hospital records has been raised as a limitation of using hospital discharge data for research. The aim of this study is to assess the impact of additional comorbidity information from prior hospital admissions on estimation of prevalence and modelling of risk factors for obstetric haemorrhage.</p> <p>Methods</p> <p>A range of chronic disease prevalence for 53,438 women who had their first birth in New South Wales (NSW), Australia, 2005-2006, were ascertained for up to five years prior to the birth admission (for pregnancy, 2-, 3-, 4- and 5-year periods) and obstetric haemorrhage was identified from maternal hospital records for 2005 and 2006.</p> <p>Results</p> <p>The ascertainment of chronic disease prevalence increased with increasing length of lookback. However, the rate of the increase was slower after 2 to 3 years than for the more recent periods. The effect size of chronic diseases on obstetric haemorrhage risk decreased with the increased case ascertainment associated with longer lookback. Furthermore, longer lookback did not improve the predictive capacity (C-statistic: 0.624) of a model that was based only on the birth admission records.</p> <p>Conclusions</p> <p>Longer ascertainment periods resulted in improved identification of chronic disease history among pregnant women, but the additional information from prior admissions did little to improve the modelling of risk factors for obstetric haemorrhage.</p

    Congenital Hypogonadotropic Hypogonadism Due to GNRH Receptor Mutations in Three Brothers Reveal Sites Affecting Conformation and Coupling

    Get PDF
    Congenital hypogonadotropic hypogonadism (CHH) is characterized by low gonadotropins and failure to progress normally through puberty. Mutations in the gene encoding the GnRH receptor (GNRHR1) result in CHH when present as compound heterozygous or homozygous inactivating mutations. This study identifies and characterizes the properties of two novel GNRHR1 mutations in a family in which three brothers display normosmic CHH while their sister was unaffected. Molecular analysis in the proband and the affected brothers revealed two novel non-synonymous missense GNRHR1 mutations, present in a compound heterozygous state, whereas their unaffected parents possessed only one inactivating mutation, demonstrating the autosomal recessive transmission in this kindred and excluding X-linked inheritance equivocally suggested by the initial pedigree analysis. The first mutation at c.845 C>G introduces an Arg substitution for the conserved Pro 282 in transmembrane domain (TMD) 6. The Pro282Arg mutant is unable to bind radiolabeled GnRH analogue. As this conserved residue is important in receptor conformation, it is likely that the mutation perturbs the binding pocket and affects trafficking to the cell surface. The second mutation at c.968 A>G introduces a Cys substitution for Tyr 323 in the functionally crucial N/DPxxY motif in TMD 7. The Tyr323Cys mutant has an increased GnRH binding affinity but reduced receptor expression at the plasma membrane and impaired G protein-coupling. Inositol phosphate accumulation assays demonstrated absent and impaired Gαq/11 signal transduction by Pro282Arg and Tyr323Cys mutants, respectively. Pretreatment with the membrane permeant GnRHR antagonist NBI-42902, which rescues cell surface expression of many GNRHR1 mutants, significantly increased the levels of radioligand binding and intracellular signaling of the Tyr323Cys mutant but not Pro282Arg. Immunocytochemistry confirmed that both mutants are present on the cell membrane albeit at low levels. Together these molecular deficiencies of the two novel GNRHR1 mutations lead to the CHH phenotype when present as a compound heterozygote
    corecore