254 research outputs found

    Refining the M_BH-V_c scaling relation with HI rotation curves of water megamaser galaxies

    Get PDF
    Black hole - galaxy scaling relations provide information about the coevolution of supermassive black holes and their host galaxies. We compare the black hole mass - circular velocity (MBH - Vc) relation with the black hole mass - bulge stellar velocity dispersion (MBH - sigma) relation, to see whether the scaling relations can passively emerge from a large number of mergers, or require a physical mechanism, such as feedback from an active nucleus. We present VLA H I observations of five galaxies, including three water megamaser galaxies, to measure the circular velocity. Using twenty-two galaxies with dynamical MBH measurements and Vc measurements extending to large radius, our best-fit MBH - Vc relation, log MBH = alpha + beta log(Vc /200 km s^-1), yields alpha = 7.43+/-0.13, beta = 3.68+1.23/-1.20, and intrinsic scatter epsilon_int = 0.51+0.11/-0.09. The intrinsic scatter may well be higher than 0.51, as we take great care to ascribe conservatively large observational errors. We find comparable scatter in the MBH - sigma relations, epsilon_int = 0.48+0.10/-0.08, while pure merging scenarios would likely result in a tighter scaling with the dark halo (as traced by Vc) than baryonic (sigma) properties. Instead, feedback from the active nucleus may act on bulge scales to tighten the MBH - sigma relation with respect to the MBH - Vc relation, as observed.Comment: 27 pages, 15 figures, ApJ accepte

    FIREBALL: Detector, data acquisition and reduction

    Get PDF
    The Faint Intergalactic Redshifted Emission Balloon (FIREBALL) had its first scientific flight in June 2009. The instrument combines microchannel plate detector technology with fiber-fed integral field spectroscopy on an unstable stratospheric balloon gondola platform. This unique combination poses a series of calibration and data reduction challenges that must be addressed and resolved to allow for accurate data analysis. We discuss our approach and some of the methods we are employing to accomplish this task

    FIREBALL: Instrument pointing and aspect reconstruction

    Get PDF
    The Faint Intergalactic Redshifted Emission Balloon (FIREBALL) had its first scientific flight in June 2009. The instrument is a 1 meter class balloon-borne telescope equipped with a vacuum-ultraviolet integral field spectrograph intended to detect emission from the inter-galactic medium at redshifts 0.3 < z < 1.0. The scientific goals and the challenging environment place strict constraints on the pointing and tracking systems of the gondola. In this manuscript we briefly review our pointing requirements, discuss the methods and solutions used to meet those requirements, and present the aspect reconstruction results from the first successful scientific flight

    The Influence of Motion and Stress on Optical Fibers

    Full text link
    We report on extensive testing carried out on the optical fibers for the VIRUS instrument. The primary result of this work explores how 10+ years of simulated wear on a VIRUS fiber bundle affects both transmission and focal ratio degradation (FRD) of the optical fibers. During the accelerated lifetime tests we continuously monitored the fibers for signs of FRD. We find that transient FRD events were common during the portions of the tests when motion was at telescope slew rates, but dropped to negligible levels during rates of motion typical for science observation. Tests of fiber transmission and FRD conducted both before and after the lifetime tests reveal that while transmission values do not change over the 10+ years of simulated wear, a clear increase in FRD is seen in all 18 fibers tested. This increase in FRD is likely due to microfractures that develop over time from repeated flexure of the fiber bundle, and stands in contrast to the transient FRD events that stem from localized stress and subsequent modal diffusion of light within the fibers. There was no measurable wavelength dependence on the increase in FRD over 350 nm to 600 nm. We also report on bend radius tests conducted on individual fibers and find the 266 microns VIRUS fibers to be immune to bending-induced FRD at bend radii of R > 10cm. Below this bend radius FRD increases slightly with decreasing radius. Lastly, we give details of a degradation seen in the fiber bundle currently deployed on the Mitchell Spectrograph (formally VIRUS-P) at McDonald Observatory. The degradation is shown to be caused by a localized shear in a select number of optical fibers that leads to an explosive form of FRD. In a few fibers, the overall transmission loss through the instrument can exceed 80%.Comment: 19 pages, 22 figure

    Mass production of volume phase holographic gratings for the VIRUS spectrograph array

    Full text link
    The Visible Integral-field Replicable Unit Spectrograph (VIRUS) is a baseline array of 150 copies of a simple, fiber-fed integral field spectrograph that will be deployed on the Hobby-Eberly Telescope (HET). VIRUS is the first optical astronomical instrument to be replicated on an industrial scale, and represents a relatively inexpensive solution for carrying out large-area spectroscopic surveys, such as the HET Dark Energy Experiment (HETDEX). Each spectrograph contains a volume phase holographic (VPH) grating with a 138 mm diameter clear aperture as its dispersing element. The instrument utilizes the grating in first-order for 350-550 nm. Including witness samples, a suite of 170 VPH gratings has been mass produced for VIRUS. Here, we present the design of the VIRUS VPH gratings and a discussion of their mass production. We additionally present the design and functionality of a custom apparatus that has been used to rapidly test the first-order diffraction efficiency of the gratings for various discrete wavelengths within the VIRUS spectral range. This device has been used to perform both in-situ tests to monitor the effects of adjustments to the production prescription as well as to carry out the final acceptance tests of the gratings' diffraction efficiency. Finally, we present the as-built performance results for the entire suite of VPH gratings.Comment: 16 pages, 11 figures, 2 tables. To be published in Proc. SPIE, 2014, "Advances in Optical and Mechanical Technologies for Telescopes and Instrumentation", 9151-53. The work presented in this article follows from arXiv:1207:448
    corecore