3 research outputs found

    Comparação do tempo de reverberação e índice de transmissão da fala (STI) em salas de aula construídas em décadas diferentes

    Get PDF
     This study compares and evaluates the reverberation times (RT) measured in two classroom buildings at the Federal University of Paraná, which were built in different decades. The RT of each room was measured according to the ISO/3382-1 standard. This paper presents simulations of RT and the speech transmission index (STI). In the simulations performed with the software ODEON, the influence of different materials on those indexes is analyzed. For one of the classrooms in the BG building, whose measured mean RT was 2.5 s, the simulations indicated the need to replace some of the finishing materials, especially on the floor and ceiling, for others with greater sound absorption coefficient. Results of the simulations pointed to a reduction in almost 2 s in RT. With respect to STI, the initial situation pointed to values between 0.39 and 0.42, which meant that intelligibility was poor, according to limits set by the IEC 60268-16 standard. The reduction in RT led STI values to range between 0.73 and 0.76, rendering intelligibility as good, according to the IEC 60268-16 standard.Este trabalho compara e avalia os valores de tempos de reverberação TR medidos em dois edifícios didáticos da Universidade Federal do Paraná construídos em épocas diferentes. O TR de cada sala foi medido segundo a norma ISO 3382-1. O presente trabalho apresenta simulações referentes ao TR e Índice de Transmissão da Fala – STI . Nas simulações realizadas com o software ODEON, é observada a influência de diferentes materiais de acabamento sobre o TR e sobre o STI.  As simulações indicaram para uma das salas do bloco JB, com TR médio de 2,5 s, a necessidade de substituição de alguns materiais de acabamento, especialmente no piso e no teto, por outros materiais com maior coeficiente de absorção sonora. Os resultados das simulações apontam para a redução de quase 2 s no TR após a substituição dos materiais do teto e piso. Com relação ao STI, a situação inicial apontava valores entre 0,39 e 0,42, o que classificava como “ruim” a inteligibilidade segundo os padrões estabelecidos pela norma IEC 60268-16. A redução do TR conduziu os resultados simulados para o STI a se situarem entre 0,73 e 0,76, sendo então a inteligibilidade classificada pela norma IEC, como “boa”

    Comparação do tempo de reverberação e índice de transmissão da fala (STI) em salas de aula construídas em décadas diferentes

    No full text
     This study compares and evaluates the reverberation times (RT) measured in two classroom buildings at the Federal University of Paraná, which were built in different decades. The RT of each room was measured according to the ISO/3382-1 standard. This paper presents simulations of RT and the speech transmission index (STI). In the simulations performed with the software ODEON, the influence of different materials on those indexes is analyzed. For one of the classrooms in the BG building, whose measured mean RT was 2.5 s, the simulations indicated the need to replace some of the finishing materials, especially on the floor and ceiling, for others with greater sound absorption coefficient. Results of the simulations pointed to a reduction in almost 2 s in RT. With respect to STI, the initial situation pointed to values between 0.39 and 0.42, which meant that intelligibility was poor, according to limits set by the IEC 60268-16 standard. The reduction in RT led STI values to range between 0.73 and 0.76, rendering intelligibility as good, according to the IEC 60268-16 standard.Este trabalho compara e avalia os valores de tempos de reverberação TR medidos em dois edifícios didáticos da Universidade Federal do Paraná construídos em épocas diferentes. O TR de cada sala foi medido segundo a norma ISO 3382-1. O presente trabalho apresenta simulações referentes ao TR e Índice de Transmissão da Fala – STI . Nas simulações realizadas com o software ODEON, é observada a influência de diferentes materiais de acabamento sobre o TR e sobre o STI.  As simulações indicaram para uma das salas do bloco JB, com TR médio de 2,5 s, a necessidade de substituição de alguns materiais de acabamento, especialmente no piso e no teto, por outros materiais com maior coeficiente de absorção sonora. Os resultados das simulações apontam para a redução de quase 2 s no TR após a substituição dos materiais do teto e piso. Com relação ao STI, a situação inicial apontava valores entre 0,39 e 0,42, o que classificava como “ruim” a inteligibilidade segundo os padrões estabelecidos pela norma IEC 60268-16. A redução do TR conduziu os resultados simulados para o STI a se situarem entre 0,73 e 0,76, sendo então a inteligibilidade classificada pela norma IEC, como “boa”

    Clinical assessment and pathophysiology of Bothrops venom-related acute kidney injury: a scoping review

    No full text
    corecore