38 research outputs found

    Monitoring Breast Cancer Response to Neoadjuvant Chemotherapy Using Ultrasound Strain Elastography

    Get PDF
    © 2019 The Authors Strain elastography was used to monitor response to neoadjuvant chemotherapy (NAC) in 92 patients with biopsy-proven, locally advanced breast cancer. Strain elastography data were collected before, during, and after NAC. Relative changes in tumor strain ratio (SR) were calculated over time, and responder status was classified according to tumor size changes. Statistical analyses determined the significance of changes in SR over time and between response groups. Machine learning techniques, such as a naïve Bayes classifier, were used to evaluate the performance of the SR as a marker for Miller-Payne pathological endpoints. With pathological complete response (pCR) as an endpoint, a significant difference (P < .01) in the SR was observed between response groups as early as 2 weeks into NAC. Naïve Bayes classifiers predicted pCR with a sensitivity of 84%, specificity of 85%, and area under the curve of 81% at the preoperative scan. This study demonstrates that strain elastography may be predictive of NAC response in locally advanced breast cancer as early as 2 weeks into treatment, with high sensitivity and specificity, granting it the potential to be used for active monitoring of tumor response to chemotherapy

    Focused Ultrasound Stimulation of Microbubbles in Combination With Radiotherapy for Acute Damage of Breast Cancer Xenograft Model

    Get PDF
    Objective: Several studies have focused on the use of ultrasound-stimulated microbubbles (USMB) to induce vascular damage in order to enhance tumor response to radiation. Methods: In this study, power Doppler imaging was used along with immunohisto- chemistry to investigate the effects of combining radiation therapy (XRT) and USMB using an ultrasound-guided focused ultrasound (FUS) therapy system in a breast cancer xenograft model. Specifically, MDA-MB-231 breast cancer xenograft tumors were induced in severe combined immuno-deficient female mice. The mice were treated with FUS alone, ultrasound and microbubbles (FUS + MB) alone, 8 Gy XRT alone, or a combined treatment consisting of ultrasound, microbubbles, and XRT (FUS + MB + XRT). Power Doppler imaging was conducted before and 24 h after treatment, at which time mice were sacrificed and tumors assessed histolog- ically. The immunohistochemical analysis included terminal deoxynucleotidyl transferase dUTP nick end labeling, hematoxylin and eosin, cluster of differentiation-31 (CD31), Ki-67, carbonic anhydrase (CA-9), and ceramide labeling. Results: Tumors receiving treat- ment of FUS + MB combined with XRT demonstrated significant increase in cell death (p = 0.0006) compared to control group. Furthermore, CD31 and Power Doppler analysis revealed reduced tumor vascularization with combined treatment indicating (P \u3c .0001) and (P = .0001), respectively compared to the control group. Additionally, lesser number of proliferating cells with enhanced tumor hypoxia, and ceramide content were also reported in group receiving a treatment of FUS + MB + XRT. Conclusion: The study results demonstrate that the combination of USMB with XRT enhances treatment outcomes

    Quantitative ultrasound delta-radiomics during radiotherapy for monitoring treatment responses in head and neck malignancies

    Get PDF
    Aim: We investigated quantitative ultrasound (QUS) in patients with node-positive head and neck malignancies for monitoring responses to radical radiotherapy (RT). Materials & methods: QUS spectral and texture parameters were acquired from metastatic lymph nodes 24 h, 1 and 4 weeks after starting RT. K-nearest neighbor and naive-Bayes machine-learning classifiers were used to build prediction models for each time point. Response was detected after 3 months of RT, and patients were classified into complete and partial responders. Results: Single-feature naive-Bayes classification performed best with a prediction accuracy of 80, 86 and 85% at 24 h, week 1 and 4, respectively. Conclusion: QUS-radiomics can predict RT response at 3 months as early as 24 h with reasonable accuracy, which further improves into 1 week of treatment

    Predictive quantitative ultrasound radiomic markers associated with treatment response in head and neck cancer

    Get PDF
    Aim: We aimed to identify quantitative ultrasound (QUS)-radiomic markers to predict radiotherapy response in metastatic lymph nodes of head and neck cancer. Materials & methods: Node-positive head and neck cancer patients underwent pretreatment QUS imaging of their metastatic lymph nodes. Imaging features were extracted using the QUS spectral form, and second-order texture parameters. Machine-learning classifiers were used for predictive modeling, which included a logistic regression, naive Bayes, and k-nearest neighbor classifiers. Results: There was a statistically significant difference in the pretreatment QUS-radiomic parameters between radiological complete responders versus partial responders (p < 0.05). The univariable model that demonstrated the greatest classification accuracy included: spectral intercept (SI)-contrast (area under the curve = 0.741). Multivariable models were also computed and showed that the SI-contrast + SI-homogeneity demonstrated an area under the curve = 0.870. The three-feature model demonstrated that the spectral slope-correlation + SI-contrast + SI-homogeneity-predicted response with accuracy of 87.5%. Conclusion: Multivariable QUS-radiomic features of metastatic lymph nodes can predict treatment response a priori

    Breast-Lesion Characterization using Textural Features of Quantitative Ultrasound Parametric Maps

    Get PDF
    © 2017 The Author(s). This study evaluated, for the first time, the efficacy of quantitative ultrasound (QUS) spectral parametric maps in conjunction with texture-analysis techniques to differentiate non-invasively benign versus malignant breast lesions. Ultrasound B-mode images and radiofrequency data were acquired from 78 patients with suspicious breast lesions. QUS spectral-analysis techniques were performed on radiofrequency data to generate parametric maps of mid-band fit, spectral slope, spectral intercept, spacing among scatterers, average scatterer diameter, and average acoustic concentration. Texture-analysis techniques were applied to determine imaging biomarkers consisting of mean, contrast, correlation, energy and homogeneity features of parametric maps. These biomarkers were utilized to classify benign versus malignant lesions with leave-one-patient-out cross-validation. Results were compared to histopathology findings from biopsy specimens and radiology reports on MR images to evaluate the accuracy of technique. Among the biomarkers investigated, one mean-value parameter and 14 textural features demonstrated statistically significant differences (p < 0.05) between the two lesion types. A hybrid biomarker developed using a stepwise feature selection method could classify the legions with a sensitivity of 96%, a specificity of 84%, and an AUC of 0.97. Findings from this study pave the way towards adapting novel QUS-based frameworks for breast cancer screening and rapid diagnosis in clinic

    Chemotherapy-Response Monitoring of Breast Cancer Patients Using Quantitative Ultrasound-Based Intra-Tumour Heterogeneities

    Get PDF
    © 2017 The Author(s). Anti-cancer therapies including chemotherapy aim to induce tumour cell death. Cell death introduces alterations in cell morphology and tissue micro-structures that cause measurable changes in tissue echogenicity. This study investigated the effectiveness of quantitative ultrasound (QUS) parametric imaging to characterize intra-tumour heterogeneity and monitor the pathological response of breast cancer to chemotherapy in a large cohort of patients (n = 100). Results demonstrated that QUS imaging can non-invasively monitor pathological response and outcome of breast cancer patients to chemotherapy early following treatment initiation. Specifically, QUS biomarkers quantifying spatial heterogeneities in size, concentration and spacing of acoustic scatterers could predict treatment responses of patients with cross-validated accuracies of 82 ± 0.7%, 86 ± 0.7% and 85 ± 0.9% and areas under the receiver operating characteristic (ROC) curve of 0.75 ± 0.1, 0.80 ± 0.1 and 0.89 ± 0.1 at 1, 4 and 8 weeks after the start of treatment, respectively. The patients classified as responders and non-responders using QUS biomarkers demonstrated significantly different survivals, in good agreement with clinical and pathological endpoints. The results form a basis for using early predictive information on survival-linked patient response to facilitate adapting standard anti-cancer treatments on an individual patient basis

    Quantitative ultrasound imaging of therapy response in bladder cancer in vivo.

    Get PDF
    Background and aimsQuantitative ultrasound (QUS) was investigated to monitor bladder cancer treatment response in vivo and to evaluate tumor cell death from combined treatments using ultrasound-stimulated microbubbles and radiation therapy.MethodsTumor-bearing mice (n=45), with bladder cancer xenografts (HT- 1376) were exposed to 9 treatment conditions consisting of variable concentrations of ultrasound-stimulated Definity microbubbles [nil, low (1%), high (3%)], combined with single fractionated doses of radiation (0 Gy, 2 Gy, 8 Gy). High frequency (25 MHz) ultrasound was used to collect the raw radiofrequency (RF) data of the backscatter signal from tumors prior to, and 24 hours after treatment in order to obtain QUS parameters. The calculated QUS spectral parameters included the mid-band fit (MBF), and 0-MHz intercept (SI) using a linear regression analysis of the normalized power spectrum.Results and conclusionsThere were maximal increases in QUS parameters following treatments with high concentration microbubbles combined with 8 Gy radiation: (ΔMBF = +6.41 ± 1.40 (±SD) dBr and SI= + 7.01 ± 1.20 (±SD) dBr. Histological data revealed increased cell death, and a reduction in nuclear size with treatments, which was mirrored by changes in quantitative ultrasound parameters. QUS demonstrated markers to detect treatment effects in bladder tumors in vivo

    Predicting Breast Cancer Response to Neoadjuvant Chemotherapy Using Pretreatment Diffuse Optical Spectroscopic-Texture Analysis

    Get PDF
    Purpose: Diffuse optical spectroscopy (DOS) has been demonstrated capable of monitoring response to neoadjuvant chemotherapy (NAC) in locally advanced breast cancer (LABC) patients. In this study, we evaluate texture features of pre-treatment DOS functional maps for predicting LABC response to NAC. Methods: LABC patients (n = 37) underwent DOS-breast imaging before starting neoadjuvant chemotherapy. Breast-tissue parametric maps were constructed and texture analyses were performed based on grey level co-occurrence matrices (GLCM) for feature extraction. Ground-truth labels as responders (R) or non-responders (NR) were assigned to patients based on Miller-Payne pathological response criteria. The capability of DOS-textural features computed on volumetric tumour data before the start of treatment (i.e. “pre-treatment”) to predict patient responses to NAC was evaluated using a leave-one-out validation scheme at subject level. Data were analysed using a logistic regression, naïve Bayes, and k-nearest neighbour (k-NN) classifiers. Results: Data indicated that textural characteristics of pre-treatment DOS parametric maps can differentiate between treatment response outcomes. The HbO2-homogeneity resulted in the highest accuracy amongst univariate parameters in predicting response to chemotherapy: sensitivity (%Sn) and specificity (%Sp) were 86.5 and 89.0%, respectively and accuracy was 87.8%. The highest predictors using multivariate (binary) combination features were the Hb-Contrast + HbO2-Homogeneity which resulted in a %Sn/%Sp = 78.0/81.0% and an accuracy of 79.5%. Conclusions: This study demonstrated that pre-treatment tumour DOS-texture features can predict breast cancer response to NAC and potentially guide treatments

    Investigation of anisotropic properties of musculoskeletal tissues by high frequency ultrasound

    Get PDF
    Knochen und Muskel sind die wichtigsten Gewebe im muskuloskelettalen System welche dem Körper die Bewegungen möglich machen. Beide Gewebetypen sind hochgradig strukturierter Extrazellulärmatrix zugrundegelegt, welche die mechanischen und biologischen Funktionen bestimmen. In dieser Studie wurden die räumliche Verteilung der anisotropen elastischen Eigenschaften und der Gewebemineralisation im humanen kortikalen Femur untersucht mit akustischer Mikroskopie und Synchrotron-µCT. Die homogenisierten elastischen Eigenschaften wurden aus einer Kombination der Porosität und der Gewebeelastizitätsmatrix mit Hilfe eines asymptotischen Homogenisierungsmodells ermittelt. Der Einfluss der Gewebemineralisierung und der Strukturparameter auf die mikroskopischen und mesoskopischen elastischen Koeffizienten wurde unter Berücksichtigung der anatomischen Position des Femurschaftes untersucht. Es wurde ein Modell entwickelt, mit welchem der intramuskuläre Fettgehalt des porcinen musculus longissimus nichtinvasiv mittels quantitativem Ultraschall und dessen spektraler Analyze des Echosignals bestimmt werden kann. Muskelspezifische Parameter wie Dämpfung, spectral slope, midband fit, apparent integrated backscatter und cepstrale Paramter wurden aus den RF-Signalen extrahiert. Die Einflüsse der Muskelkomposition und Strukturparameter auf die spektralen Ultraschallparameter wurden untersucht. Die akustischer Parameter werden durch die Muskelfaserorientierung beeinflusst und weisen höhere Werte parallel zur Faserlängsrichtung als senkrecht zur Faserorientierung auf. Die in dieser Studie gewonnenen detaillierten und lokal bestimmten Knochendaten können möglicherweise als Eingabeparameter für numerische 3D FE-Simulationen. Darüber hinaus kann die Untersuchung von Veränderungen der lokalen Gewebeanisotropie neue Einsichten in Studien über Knochenumbildung geben. Diese auf Gewebeebene bestimmten Daten von Muskelgewebe können in numerischen Simulationen von akustischer Rückstreuung genutzt werden um diagnostische Methoden und Geräte zu verbessern.Bone and muscle are the most important tissues in the musculoskeletal system that gives the ability to move the body. Both tissues have the highly oriented underlying extracellular matrix structure for performing mechanical and biological functions. In this study, the spatial distribution of anisotropic elastic properties and tissue mineralization within a human femoral cortical bone shaft were investigated using scanning acoustic microscopy and synchrotron radiation µCT. The homogenized meoscopic elastic properties were determined by a combination of porosity and tissue elastic matrix using a asymptotic homogenization model. The impact on tissue mineralization and structural parameters of the microscopic and mesocopic elastic coefficients was analyzed with respect to the anatomical location of the femoral shaft. A model was developed to estimate intramuscular fat of porcine musculus longissimus non-invasively using a quantitative ultrasonic device by spectral analysis of ultrasonic echo signals. Muscle specific acoustic parameters, i.e. attenuation, spectral slope, midband fit, apparent integrated backscatter, and cepstral parameters were extracted from the measured RF echoes. The impact of muscle composition and structural properties on ultrasonic spectral parameters was analyzed. The ultrasound propagating parameters were affected by the muscle fiber orientation. The most dominant direction dependency was found for the attenuation. The detailed locally assessed bone data in this study may serve as a real-life input for numerical 3D FE simulation models. Moreover, the assessment of changes of local tissue anisotropy may provide new insights into the bone remodelling studies. The data provided at tissue level and investigated ultrasound backscattering from muscle tissue, can be used in numerical simulation FE models for acoustical backscattering from muscle for the further improvement of diagnostic methods and equipment
    corecore