22 research outputs found
Recommended from our members
The Use of a Pressure-Indicating Film to Determine the Effect of Liner Type on the Measured Teat Load Caused by a Collapsing Liner
During milking the teat cup liner is the interface between the teat of a dairy cow and the milking system, so it should be very well adapted to the teat. Therefore, the aim of the present study was to determine the effect of liner type on the directly measuring teat load caused by a collapsing liner with a pressure-indicating film. The Extreme Low pressure-indicating film was used to detect the effect of six different liners on teat load. For each liner, six positions in the teat cup were specified, and six repetitions were performed for each position with a new piece of film each time. Analysis of variance was performed to detect differences between the six liners, the positions within a liner, and the measuring areas. The pressure applied to the teat by a liner depends on the technical characteristics of the liner, especially the shape of the barrel, and for all tested liners, a higher teat load was found at the teat end. In conclusion, with the help of pressure-indicating film, it is possible to determine the different effects of liner type by directly measuring teat load due to liner collapse. © 2017 by the authors. Licensee MDPI, Basel, Switzerland
Recommended from our members
Comparative study of behavioural and milking traits in cows milked with a conventional or individual quarter milking system (Multilactor®) and with different milking persons
The aim of this study was to investigate the influence of a new type of milking system on the behaviour of cows during milking by comparing a conventional milking system (CON) with an individual quarter milking system (MUL), MultiLactor®. Sixty-eight dairy cows were observed during their milking times (32 cows in CON, 36 cows in MUL) using video recordings to analyse their behavioural traits. The udder preparation duration, milking duration and milk yield were also evaluated. No significant differences were found between the CON and the MUL regarding cows' head posture (P=0.38), body posture (P=0.85), number of steps (P=0.08) and number of kicks (P=0.56). However, the milk yield was lower (P=0.02), just as the udder preparation duration (P<0.01) and milking duration (P=0.01) were shorter in the CON compared to the MUL. In addition, in regard to the milking person, differences were displayed in the head posture of the milked cows, kick-off or loss of teat cup or milking cluster, and frequency of udder preparation. In conclusion, the investigated milking systems did not markedly influence the behaviour of dairy cows; however, udder preparation duration, milking duration and milk yield were significantly greater for the MUL than for the CON. However, the milking person appears to have a greater impact on the behaviour of the cows than the milking system. © 2017 Sciendo. All Rights Reserved
Recommended from our members
The usability of a pressure-indicating film to measure the teat load caused by a collapsing liner
Prevention of damage to the teat and mastitis requires determination of the teat load caused by a collapsing liner. The aim of this study was to test a pressure-indicating film designed to measure the pressure between a collapsing liner and artificial teats. The Ultra Super Low and the Extreme Low pressure-indicating films were tested on two types of artificial teat. The experiments were performed with a conventional milking cluster equipped with round silicone liners. For each teat and film type, 30 repetitions were performed. Each repetition was performed with a new piece of film. Kruskal-Wallis tests were performed to detect differences between the pressure values for the different teats. The area of regions where pressure-indication color developed was calculated to determine the most suitable film type. Both film types measured the pressure applied to both artificial teats by the teat cup liner. Thus, the pressure-indicating films can be used to measure the pressure between a collapsing liner and an artificial teat. Based on the results of the present investigation, a pressure-indicating film with the measurement ranges of both film types combined would be an optimal tool to measure the overall pressure between an artificial teat and a collapsing liner
Recommended from our members
Viertelindividuelle Vakuumapplikation fĂĽr moderne Melksysteme
Durch den Einsatz von viertelindividueller Melktechnik können die Bedingungen für Melkpersonal
und KĂĽhe erheblich verbessert werden. Die getrennte SchlauchfĂĽhrung fĂĽr die Milch aus
den vier Eutervierteln bietet deutliche Vorteile fĂĽr die technische Weiterentwicklung dieser
Melksysteme. Im Folgenden wird der Prototyp eines viertelindividuellen Melksystems mit Vakuumregelungseinheit
vorgestellt, der eine milchflussabhängige, präzise Vakuumanpassung für
jedes Euterviertel, verbunden mit einer hohen Rate von Sollwert-Istwert-Abgleichen durch die
Regelungseinheit, ermöglicht.Using individual quarter milking systems can substantially
improve the conditions for milkers and dairy cows. A separate
conduction of the milk from the four udder quarters
leads to distinctive benefits for the further technical development
of these milking systems. A prototype of an individual
quarter-wise working milking system with a vacuum control
system allows a precise vacuum adjustment per quarter with
a high response rate of the control system, based on the
milk-flow of each udder quarter
Recommended from our members
Entwicklung einer zentralen Online-Analyse und Steuerungseinheit zur Milchgewinnung "OASE" : Schlussbericht zum Projekt "OASE" ; Berichtszeitraum: 01. Februar 2008 bis 31. August 2011
[no abstract available
The Usability of a Pressure-Indicating Film to Measure the Teat Load Caused by a Collapsing Liner
Prevention of damage to the teat and mastitis requires determination of the teat load caused by a collapsing liner. The aim of this study was to test a pressure-indicating film designed to measure the pressure between a collapsing liner and artificial teats. The Ultra Super Low and the Extreme Low pressure-indicating films were tested on two types of artificial teat. The experiments were performed with a conventional milking cluster equipped with round silicone liners. For each teat and film type, 30 repetitions were performed. Each repetition was performed with a new piece of film. Kruskal-Wallis tests were performed to detect differences between the pressure values for the different teats. The area of regions where pressure-indication color developed was calculated to determine the most suitable film type. Both film types measured the pressure applied to both artificial teats by the teat cup liner. Thus, the pressure-indicating films can be used to measure the pressure between a collapsing liner and an artificial teat. Based on the results of the present investigation, a pressure-indicating film with the measurement ranges of both film types combined would be an optimal tool to measure the overall pressure between an artificial teat and a collapsing liner
Recommended from our members
Development of a control system for the teat-end vacuum in individual quarter milking systems
Progress in sensor technique and electronics has led to a decrease in the costs of electronic and sensor components. In modern dairy farms, having udders in good condition, a lower frequency of udder disease and an extended service life of dairy cows will help ensure competitiveness. The objective of this study was to develop a teat-end vacuum control system with individual quarter actor reaction. Based on a review of the literature, this system is assumed to protect the teat tissue. It reduces the mean teat-end vacuum in the maximum vacuum phase (b) to a level of 20 kPa at a flow rate of 0.25 L/min per quarter. At flow rates higher than 1.50 L/min per quarter, the teat-end vacuum can be controlled to a level of 30 kPa, because in this case it is desirable to have a higher vacuum for the transportation of the milk to the receiver. With this system it is possible for the first time to supply the teat end with low vacuum at low flow rates and with higher vacuum at increasing flow rates in a continuous process with a three second reaction-rate on individual quarter level. This system is completely automated
Sensor-Based Detection of the Severity of Hyperkeratosis in the Teats of Dairy Cows
The aim of this study was to evaluate whether the severity of hyperkeratosis (HK) in the teats of dairy cows can be assessed by a dielectric measurement. The study focused on surveying the occurrence of hyperkeratosis in a total of 241 teats of lactating dairy cows. A scoring system consisting of four categories was used to macroscopically assess the severity of HK. Additionally, the dielectric constant (DC) of all teats with milkability was measured in a double iteration with the MoistureMeterD (Delfin Technologies, Kuopio, Finland) on four different days. The Spearman rank correlation coefficient revealed a negative correlation between the DC and HK score (rs = −0.55 to −0.36). The results of the regression analysis showed that the DC values differed significantly between healthy teat ends (≤2) and teat ends with HK (≥3). Thus, the non-invasive measurement of DC provides a promising method of objectively assessing the occurrence and severity of HK
Influence of an active stable system on the behavior and body condition of Icelandic horses
Horses are often stabled in individual boxes, a method that does not meet their natural needs and may cause psychical and musculoskeletal diseases. This problem is particularly evident in Iceland, where horses often spend the long winter periods in cramped boxes. The aim of this study was to analyze the suitability of a group housing system in Iceland, but the results are also applicable to horses of other regions. Eight Icelandic horses were observed in an active stable system, and their behavior and time budget were recorded. Movement and lying behavior were studied with ALT (Activity, Lying, Temperature detection) pedometers. The effect of an automatic concentrate feeding station (CFS) on the horses’ behavior was examined. In the first period of investigation, the horses were fed concentrates manually, and in the second period, they were fed with the CFS. Additional behavioral observations and a determination of social hierarchy occurred directly or by video surveillance. The physical condition of the horses was recorded by body weight (BW) measurement and body condition scoring (BCS). The results showed a significant increase between the first and second trial periods in both the activity (P < 0.001) and the lying time (P = 0.003) of the horses with use of the CFS. However, there was no significant change in BW during the first period without the CFS (P = 0.884) or during the second period with the CFS (P = 0.540). The BCS of the horses was constant at a very good level during both trial periods, and the horses showed a low level of aggression, a firm social hierarchy and behavioral synchronization. This study concludes that group housing according to the active stable principle is a welfare-friendly option for keeping horses and is a suitable alternative to conventional individual boxes.Peer Reviewe