72 research outputs found

    Occurrence of Legionella spp. in Man-Made Water Sources: Isolates Distribution and Phylogenetic Characterization in the Emilia-Romagna Region

    Get PDF
    Legionella species distribution in the Emilia-Romagna region, involving hospital (H) and community (C) environments, was conducted. Legionella culture, agglutination test, and mip-gene sequencing were applied on 240 isolates. The analysis showed a higher prevalence of non-Legionellapneumophila (n-Lp) species (84.1%) compared with L. pneumophila (Lp) (15.9%), with a higher frequency of n-Lp with respect to Lp species in both environments (77.6% and 96.4%, in H and C, respectively). The Shannon index showed a significant difference in Legionella distribution (p = 0.00017), with a significant abundance of Lp in the H compared with C environment (p = 0.00028). The continuous disinfection treatment in H could contribute to adaptive survival of the Lp species. Phylogenetic analysis revealed a conservative clade distribution between H and C: L. feeleii clade with three subclades in C and the Lp clade with five subclades in H and two in C, respectively. Our findings suggest the importance of Legionella surveillance both in H and C, with a focus on n-Lp species less connected to human disease. The Legionella prevalence and diversity found here indicate that geographical and temporal isolate evolution should be considered during surveillance, particularly in the light of global warming and changes in population risk factors

    Comparison between two types of dental unit waterlines: how evaluation of microbiological contamination can support risk containment

    Get PDF
    Infection risk management in a dental unit waterline (DUWL) involves healthcare personnel and patients and is related to routine exposure to water and aerosols that may contain bacterial species. To improve water safety plans, maintenance, and sanitation procedures, analyses of heterotrophic plate counts (HPCs) at 36 \ub0C and two other microorganisms frequently associated with biofilms, Pseudomonas aeruginosa and Legionella spp., were performed in order to evaluate differences in microbiological contamination between two types of DUWLs: Type A, provided by a water tank, and Type B, directly connected to municipal water. The data showed that the water supply and water safety plan differentially influenced microbiological contamination: Type A DUWLs were more contaminated than Type B DUWLs for all microbiological parameters tested, with significant changes in the percentage of positive samples and contamination levels that were beyond the limits of standard guidelines. The results obtained show how the storage tank, the absence of antiretraction valves, and the disinfection procedures performed are the main critical points of Type A DUWLs, confirming that dental unit management (maintenance/sanitization) is often missed or not correctly applied by stakeholders, with an underestimation of the real risk of infection for patients and operators

    Different Trends in Microbial Contamination between Two Types of Microfiltered Water Dispensers: From Risk Analysis to Consumer Health Preservation

    Get PDF
    The use of microfiltered water dispensers (MWDs) for treatment of municipal water is increasing rapidly, however, the water quality produced by MWDs has not been widely investigated. In this work a large-scale microbiological investigation was conducted on 46 MWDs. In accordance with Italian regulations for drinking water, we investigated the heterotrophic plate counts at 36 and 22 C for indicator bacteria and pathogenic bacteria, such as Enterococci, Pseudomonas aeruginosa, Escherichia coli and Staphylococcus aureus. Two different MWDs were compared: Type A with Ag+ coated carbon filter and two ultraviolet (UV) lamps, and Type B with a carbon filter and one UV lamp. For each type, the contamination of the input and output points was analyzed. Our findings showed that MWDs are a source of bacteria growth, with output being more contaminated than the input point. Type B was widely contaminated for all parameters tested in both sampling points, suggesting that water treatment by Type A is more effective in controlling bacterial contamination. MWDs are critical devices for water treatment in term of technologies, intended use, and sanitization procedures. The adoption of an appropriate drinking water safety plan associated with clear maintenance procedures and periodic environmental monitoring can ensure the safe and healthy operation of these devices

    First water safety plan approach applied to a Dental Clinic complex: identification of new risk factors associated with Legionella and P. aeruginosa contamination, using a novel sampling, maintenance and management program

    Get PDF
    Dental unit waterlines (DUWLs) represent a complex environment able to promote microbial contamination, due to functional, mechanical and practical risk factors. According to a water safety plan approach, the main goal is to preserve the health of dentists, dental staff and patients. The aim of this study is to develop a DUWLs water safety plan that is able to support correct and effective maintenance and disinfection procedures. Three different water systems serve 60 dental chairs: (i) water that comes directly from municipal water (Type A), (ii) water supplied by municipal water and water bottles (Type B) and (iii) water supplied only via water bottles (Type C). For each type, Legionella and Pseudomonas aeruginosa contamination was studied, by applying a new sampling scheme, based on separate sampling from water bottles, cup filler and handpieces. Type B DUWL is the only type of DUWL contaminated by L. pneumophila (ST 59) and L. anisa (mean contamination: 608.33 ± 253.33 cfu/L) detected in cup filler and handpieces, as well as the high presence of P. aeruginosa (44.42 ± 13.25 cfu/100 mL). Two subsequent shock treatments and resampling procedures were performed by increasing disinfectant dosage and contact time and removing some DUWL components linked to biofilm growth in DUWLs. A significant reduction of contamination was obtained for both microorganisms (Legionella spp.: −100%, p < 0.001 and P. aeruginosa: −99.86%, p = 0.006). The sampling strategy proposed allows us to identify the source of contamination and better focus on the maintenance and disinfection procedures. DUWLs represent an environment that requires a multidisciplinary approach, combining the knowledge of all DUWL components to correct procedures that are able to preserve the health of personnel and patients, as well as guaranteeing DUWLs’ safe functionality

    Draft Genome Sequence of Legionella Species Isolated from Drinking Water in an Italian Industry

    Get PDF
    We report the draft genome sequences of an environmentalLegionellastrainisolated from an industrial water distribution system in Italy. Macrophage infectivity poten-tiator (mip)andb-subunit of RNA polymerase (rpoB) genes were used to perform the spe-cies identification. Whole-genome sequencing (WGS) and average nucleotide identity (ANI)identified the isolate as belonging to a presumptive novelLegionellaspecies, with a ge-nome length of 3,281,851 bp

    Decreasing incidence and changes in serotype distribution of invasive pneumococcal disease in persons aged under 18 years since introduction of 10-valent and 13-valent conjugate vaccines in Portugal, July 2008 to June 2012

    Get PDF
    Eurosurveillance. © 2007 - 2021. All rights reservedThe 10-valent pneumococcal conjugate vaccine (PCV10) became available in Portugal in mid-2009 and the 13-valent vaccine (PCV13) in early 2010. The incidence of invasive pneumococcal disease (IPD) in patients aged under 18 years decreased from 8.19 cases per 100,000 in 2008–09 to 4.52/100,000 in 2011–12. However, IPD incidence due to the serotypes included in the 7-valent conjugate vaccine (PCV7) in children aged under two years remained constant. This fall resulted from significant decreases in the number of cases due to: (i) the additional serotypes included in PCV10 and PCV13 (1, 5, 7F; from 37.6% to 20.6%), particularly serotype 1 in older children; and (ii) the additional serotypes included in PCV13 (3, 6A, 19A; from 31.6% to 16.2%), particularly serotype 19A in younger children. The decrease in serotype 19A before vaccination indicates that it was not triggered by PCV13 administration. The decrease of serotype 1 in all groups, concomitant with the introduction of PCV10, is also unlikely to have been triggered by vaccination, although PCVs may have intensified and supported these trends. PCV13 serotypes remain major causes of IPD, accounting for 63.2% of isolates recovered in Portugal in 2011–12, highlighting the potential role of enhanced vaccination in reducing paediatric IPD in Portugal.S.I. Aguiar and A.N. Horácio were supported by grants SFRH/BPD/78376/2011and SFRH/BD/81205/2011, respectively, from Fundação para a Ciência e Tecnologia, Portugal. This work was partially supported by Fundação para a Ciência e Tecnologia, Portugal (PTDC/DTP-EPI/1759/2012) and unrestricted research grants from Pfizer and GlaxoSmithKline.info:eu-repo/semantics/publishedVersio

    Cooling towers influence in an urban environment: A predictive model to control and prevent Legionella risk and Legionellosis events

    Get PDF
    Cooling towers (CTs) are used to dissipate excess heat from water by evaporation, common in large facilities as hospital, companies, and hotels. The main risk attributed to CTs is represented by Legionella, a Gram-negative bacterium associated with a severe form of pneumonia known as Legionnaires' disease (LD). The infection route is by inhalation of aerosols reaching the lower respiratory tract. Despite several events associated with CTs, the knowledge in this field is still limited. The aim of this study was to develop a predictive model of bioaerosol dispersion using PM10 particles as a proxy, to generate risk maps of Legionella spread in the surrounding area in several weather and microbiological conditions. The Legionella contamination in the CT basin was 40938 ± 24523 cfu/L, with four peaks independent of the season, associated with an increase in air minimum temperature values (+1–2 °C) and a high relative humidity (66–100%) preceded by rainfall (0.2–30.6 mm/day). The model revealed that the most extensive bioaerosol spread is predicted in winter and summer, with an increase in Legionella risk at a distance of up to 1.5 km from the CT. This method represents a novel integrated approach for the prevention and management of LD risk in CTs

    The Potential Role of Hybrid Constructed Wetlands Treating University Wastewater\u2014Experience from Northern Italy

    Get PDF
    University wastewater is a type of wastewater with higher pollutants load and flow rate variability than typical domestic wastewater. Constructed wetlands (CW) could be used for university wastewater treatment and consequently for wastewater reuse. A hybrid CW pilot plant, at the University of Bologna (Italy), was monitored to assess its potential to be used at the university. Its treatment performance was monitored for one year and public acceptance explored through a survey. The pilot plant had two treatment lines, (1) a vertical flow CW (VFCW) and a planted horizontal flow CW (HFCW), and (2) the same VFCW and an unplanted horizontal flow filter (HFF). The HFCW achieved higher removals than the HFF, but it was also found to be prone to higher water losses. However, both treatment lines met the Italian limits for discharge in natural water bodies and some of the limits for wastewater reuse in Italy and the EU. The VFCW alone was not able to meet the same limits, demonstrating the advantages of hybrid over single stage CWs. A positive attitude towards CWs and wastewater reuse was found among the survey participants. Therefore, hybrid CWs (planted and unplanted) are considered a feasible technology for application at universities
    • …
    corecore