8 research outputs found

    Evaluation of Patient Radiation Doses in Skull Radiography

    Get PDF
    Purpose: Exposures to medical ionizing radiations elevate the risk of stochastic effects such as cancer in exposed individuals. It is of utmost importance to monitor the radiation doses delivered to patients and their optimization to reduce the associated radiation risks without limiting the diagnostic information. Methods: Entrance surface air kerma (ESAK) in a total of 64 adult patients in diagnostic digital Xray examinations were calculated and effective doses were estimated as per International Atomic Energy Agency (IAEA). Results: Median ESAK (mGy) and associated effective doses obtained were skull PA (0.45mGy, 0.005mSv) and skull Lat (0.25mGy, 0.003mSv). Results were compared with UK diagnostic reference levels and studies in India.Conclusion: The comparison revealed that the calculated ESAK and effective dose values wereless than the published literature. ESAK values reported in this study could further contribute toestablishing LDRLs

    Photo-catalytic activity of Zn1-xMnxS nanocrystals synthesized by wet chemical technique

    Get PDF
    Polyvinyl pyrrolidone capped Zn1-xMnxS (0 ≤ x ≤ 0.1) nanocrystals have been synthesized using wet chemical co-precipitation method. Crystallographic and morphological characterization of the synthesized materials have been done using X-ray diffraction and transmission electron microscope. Crystallographic studies show the zinc blende crystals having average crystallite size approx. 3 nm, which is almost similar to the average particle size calculated from electron micrographs. Atomic absorption spectrometer has been used for qualitative and quantitative analysis of synthesized nanomaterials. Photo-catalytic activity has been studied using methylene blue dye as a test contaminant. Energy resolved luminescence spectra have been recorded for the detailed description of radiative and non-radiative recombination mechanisms. Photo-catalytic activity dependence on dopant concentration and luminescence quantum yield has been studied in detail

    Photo-catalytic activity of Zn<sub>1-<it>x</it> </sub>Mn<sub> <it>x</it> </sub>S nanocrystals synthesized by wet chemical technique

    No full text
    Abstract Polyvinyl pyrrolidone capped Zn1-x Mn x S (0 &#8804; x &#8804; 0.1) nanocrystals have been synthesized using wet chemical co-precipitation method. Crystallographic and morphological characterization of the synthesized materials have been done using X-ray diffraction and transmission electron microscope. Crystallographic studies show the zinc blende crystals having average crystallite size approx. 3 nm, which is almost similar to the average particle size calculated from electron micrographs. Atomic absorption spectrometer has been used for qualitative and quantitative analysis of synthesized nanomaterials. Photo-catalytic activity has been studied using methylene blue dye as a test contaminant. Energy resolved luminescence spectra have been recorded for the detailed description of radiative and non-radiative recombination mechanisms. Photo-catalytic activity dependence on dopant concentration and luminescence quantum yield has been studied in detail.</p

    Estimates of patient doses and kerma-area product monitoring in digital radiography

    No full text
    The application of the kerma-area product (PKA) meter is increased rapidly in dosimetry. This study presents measurements of PKA in adherence to the International Atomic Energy Agency protocol for 300 adult patients in digital radiographic procedures. Effective doses (ED) were calculated from PKA measurements and conversion coefficients (E-103/PKA) obtained from the International Commission on radiological protection 103. In skull posteroanterior (PA), skull lateral (LAT), cervical spine anteroposterior (AP), cervical spine LAT, chest PA, abdomen AP, lumbar spine AP, pelvis AP and lumbar spine LAT, the third-quartile PKA values were found to be 0.2, 0.28, 0.33, 0.19, 0.26, 0.95, 0.93, 0.96 and 3.15 Gycm2, and estimated mean EDs were 0.005, 0.008, 0.056, 0.021, 0.037, 0.146, 0.165, 0.097 and 0.258 mSv, respectively. The third-quartile PKA values were suggested as local diagnostic reference levels (LDRLs). Results were compared with the diagnostic reference levels (DRLs) of the UK, the European Commission, previously published LDRLs in Greece and China by Metaxas et al. and Zhang and Chu, respectively. The PKA (third-quartile) value for cervical spine AP was 120% higher than UK 2010 DRLs, lumbar spine LAT was 123% higher than LDRLs given by Metaxas et al. and chest PA was 160% higher than UK 2010 DRLs and 225% higher than Metaxas et al. provided LDRLs. The PKA results were lower than the UK, and two studies in Greece by Metaxas et al. except for chest PA, cervical spine AP and lumbar spine LAT showed the need for further optimization. The LDRLs reported in this study may further contribute to establishing future national DRLs

    Estimation of entrance surface air kerma in digital radiographic examinations

    No full text
    Purpose: Contribution of radiation doses from medical X-ray examination to collective dose is significant. Unusually, high doses may increase the risk of stochastic effects of radiations. Therefore, radiation dose assessment was performed in 241 digital X-ray examinations in the study and was compared with published dose reference levels (DRLs). Methods: Entrance surface air kerma (ESAK) was calculated in chest PA, cervical AP/Lat, abdomen AP, lumbar AP/Lat and pelvis AP digital radiographic examinations (119 male and 122 female) following the International Atomic Energy Agency recommended protocol. Initially, 270 digital examinations were selected, reject analysis was performed and final 241 examinations were enrolled in the study for dose calculations. The exposure parameters and X-ray tube output were used for dose calculations. Effective doses were estimated with the help of conversion coefficients from ICRP 103. Results: Median ESAK (mGy) and associated effective doses obtained were cervical spine AP (1.30 mGy, 0.045 mSv), cervical spine Lat (0.25 mGy, 0.005 mSv), chest PA (0.11 mGy, 0.014 mSv), abdomen AP (0.90 mGy, 0.118 mSv), lumbar spine AP (1.52 mGy, 0.177 mSv), lumbar spine Lat (7.76 mGy, 0.209 mSv) and pelvis AP (0.82 mGy, 0.081 mSv). Results were compared with the studies of UK, Oman, India and Canada. Conclusion: The calculated ESAK and effective dose values were less than or close to previously published literature except for cervical spine AP and lumbar spine Lat. The results reinforce the need for radiation protection optimization, improving examination techniques and appropriate use of automatic exposure control in digital radiography. ESAK values reported in this study could further contribute to establishing local DRLs, regional DRLs and national DRLs