13 research outputs found

    Are slaughterhouse-obtained livers suitable for use in ex vivo perfusion research?

    Get PDF
    Objectives: The success of the ex vivo machine perfusion of pig livers used for preclinical research depends on organ quality and availability. In this study, we investigated whether livers obtained from slaughterhouses are suitable and equivalent to livers obtained from laboratory pigs. Methods: Livers were obtained from slaughterhouse pigs stunned by electrocution or CO2 inhalation and from laboratory pigs. For the latter group, 45 minutes of warm ischemia was mimicked for a subgroup, ensuring a valid comparison with slaughterhouse-derived livers. Results: Livers from CO2-stunned pigs showed lower indocyanine green clearance and bile production, higher blood lactate and potassium concentrations, and higher alanine aminotransferase activities than electrically stunned pigs. Furthermore, livers from electrically stunned pigs, and livers from laboratory pigs, subjected or not to warm ischemia, showed similar performance in terms of perfusion and metabolism. Conclusion: For an ex vivo liver model generated using slaughterhouse pigs, electrical stunning is preferable to CO2 stunning. Livers from electrically stunned slaughterhouse pigs performed similarly to laboratory pig livers. These findings support the use of livers from electrically stunned slaughterhouse pigs, which may therefore provide an alternative to livers obtained from laboratory pigs, consistent with the principle of the 3Rs.</p

    Are slaughterhouse-obtained livers suitable for use in ex vivo perfusion research?

    Get PDF
    OBJECTIVES: The success of the ex vivo machine perfusion of pig livers used for preclinical research depends on organ quality and availability. In this study, we investigated whether livers obtained from slaughterhouses are suitable and equivalent to livers obtained from laboratory pigs. METHODS: Livers were obtained from slaughterhouse pigs stunned by electrocution or CO 2 inhalation and from laboratory pigs. For the latter group, 45 minutes of warm ischemia was mimicked for a subgroup, ensuring a valid comparison with slaughterhouse-derived livers. RESULTS: Livers from CO 2-stunned pigs showed lower indocyanine green clearance and bile production, higher blood lactate and potassium concentrations, and higher alanine aminotransferase activities than electrically stunned pigs. Furthermore, livers from electrically stunned pigs, and livers from laboratory pigs, subjected or not to warm ischemia, showed similar performance in terms of perfusion and metabolism. CONCLUSION: For an ex vivo liver model generated using slaughterhouse pigs, electrical stunning is preferable to CO 2 stunning. Livers from electrically stunned slaughterhouse pigs performed similarly to laboratory pig livers. These findings support the use of livers from electrically stunned slaughterhouse pigs, which may therefore provide an alternative to livers obtained from laboratory pigs, consistent with the principle of the 3Rs

    High level of polarized engraftment of porcine intrahepatic cholangiocyte organoids in decellularized liver scaffolds

    Get PDF
    In Europe alone, each year 5500 people require a life-saving liver transplantation, but 18% die before receiving one due to the shortage of donor organs. Whole organ engineering, utilizing decellularized liver scaffolds repopulated with autologous cells, is an attractive alternative to increase the pool of available organs for transplantation. The development of this technology is hampered by a lack of a suitable large-animal model representative of the human physiology and a reliable and continuous cell source. We have generated porcine intrahepatic cholangiocyte organoids from adult stem cells and demonstrate that these cultures remained stable over multiple passages whilst retaining the ability to differentiate into hepatocyte- and cholangiocyte-like cells. Recellularization onto porcine scaffolds was efficient and the organoids homogeneously differentiated, even showing polarization. Our porcine intrahepatic cholangiocyte system, combined with porcine liver scaffold paves the way for developing whole liver engineering in a relevant large-animal model

    Normothermic Ex Vivo Liver Platform Using Porcine Slaughterhouse Livers for Disease Modeling

    Get PDF
    Metabolic and toxic liver disorders, such as fatty liver disease (steatosis) and drug-induced liver injury, are highly prevalent and potentially life-threatening. To allow for the study of these disorders from the early stages onward, without using experimental animals, we collected porcine livers in a slaughterhouse and perfused these livers normothermically. With our simplified protocol, the perfused slaughterhouse livers remained viable and functional over five hours of perfusion, as shown by hemodynamics, bile production, indocyanine green clearance, ammonia metabolism, gene expression and histology. As a proof-of-concept to study liver disorders, we show that an infusion of free fatty acids and acetaminophen results in early biochemical signs of liver damage, including reduced functionality. In conclusion, the present platform offers an accessible system to perform research in a functional, relevant large animal model while avoiding using experimental animals. With further improvements to the model, prolonged exposure could make this model a versatile tool for studying liver diseases and potential treatments

    Drug Metabolism of Hepatocyte-like Organoids and Their Applicability in In Vitro Toxicity Testing

    No full text
    Emerging advances in the field of in vitro toxicity testing attempt to meet the need for reliable human-based safety assessment in drug development. Intrahepatic cholangiocyte organoids (ICOs) are described as a donor-derived in vitro model for disease modelling and regenerative medicine. Here, we explored the potential of hepatocyte-like ICOs (HL-ICOs) in in vitro toxicity testing by exploring the expression and activity of genes involved in drug metabolism, a key determinant in drug-induced toxicity, and the exposure of HL-ICOs to well-known hepatotoxicants. The current state of drug metabolism in HL-ICOs showed levels comparable to those of PHHs and HepaRGs for CYP3A4; however, other enzymes, such as CYP2B6 and CYP2D6, were expressed at lower levels. Additionally, EC50 values were determined in HL-ICOs for acetaminophen (24.0–26.8 mM), diclofenac (475.5–>500 µM), perhexiline (9.7–>31.5 µM), troglitazone (23.1–90.8 µM), and valproic acid (>10 mM). Exposure to the hepatotoxicants showed EC50s in HL-ICOs comparable to those in PHHs and HepaRGs; however, for acetaminophen exposure, HL-ICOs were less sensitive. Further elucidation of enzyme and transporter activity in drug metabolism in HL-ICOs and exposure to a more extensive compound set are needed to accurately define the potential of HL-ICOs in in vitro toxicity testing

    Normothermic Ex Vivo Liver Platform Using Porcine Slaughterhouse Livers for Disease Modeling

    No full text
    Metabolic and toxic liver disorders, such as fatty liver disease (steatosis) and drug-induced liver injury, are highly prevalent and potentially life-threatening. To allow for the study of these disorders from the early stages onward, without using experimental animals, we collected porcine livers in a slaughterhouse and perfused these livers normothermically. With our simplified protocol, the perfused slaughterhouse livers remained viable and functional over five hours of perfusion, as shown by hemodynamics, bile production, indocyanine green clearance, ammonia metabolism, gene expression and histology. As a proof-of-concept to study liver disorders, we show that an infusion of free fatty acids and acetaminophen results in early biochemical signs of liver damage, including reduced functionality. In conclusion, the present platform offers an accessible system to perform research in a functional, relevant large animal model while avoiding using experimental animals. With further improvements to the model, prolonged exposure could make this model a versatile tool for studying liver diseases and potential treatments

    Drug Metabolism of Hepatocyte-like Organoids and Their Applicability in In Vitro Toxicity Testing

    Get PDF
    Emerging advances in the field of in vitro toxicity testing attempt to meet the need for reliable human-based safety assessment in drug development. Intrahepatic cholangiocyte organoids (ICOs) are described as a donor-derived in vitro model for disease modelling and regenerative medicine. Here, we explored the potential of hepatocyte-like ICOs (HL-ICOs) in in vitro toxicity testing by exploring the expression and activity of genes involved in drug metabolism, a key determinant in drug-induced toxicity, and the exposure of HL-ICOs to well-known hepatotoxicants. The current state of drug metabolism in HL-ICOs showed levels comparable to those of PHHs and HepaRGs for CYP3A4; however, other enzymes, such as CYP2B6 and CYP2D6, were expressed at lower levels. Additionally, EC50 values were determined in HL-ICOs for acetaminophen (24.0-26.8 mM), diclofenac (475.5-&gt;500 µM), perhexiline (9.7-&gt;31.5 µM), troglitazone (23.1-90.8 µM), and valproic acid (&gt;10 mM). Exposure to the hepatotoxicants showed EC50s in HL-ICOs comparable to those in PHHs and HepaRGs; however, for acetaminophen exposure, HL-ICOs were less sensitive. Further elucidation of enzyme and transporter activity in drug metabolism in HL-ICOs and exposure to a more extensive compound set are needed to accurately define the potential of HL-ICOs in in vitro toxicity testing

    High level of polarized engraftment of porcine intrahepatic cholangiocyte organoids in decellularized liver scaffolds

    Get PDF
    In Europe alone, each year 5500 people require a life-saving liver transplantation, but 18% die before receiving one due to the shortage of donor organs. Whole organ engineering, utilizing decellularized liver scaffolds repopulated with autologous cells, is an attractive alternative to increase the pool of available organs for transplantation. The development of this technology is hampered by a lack of a suitable large-animal model representative of the human physiology and a reliable and continuous cell source. We have generated porcine intrahepatic cholangiocyte organoids from adult stem cells and demonstrate that these cultures remained stable over multiple passages whilst retaining the ability to differentiate into hepatocyte- and cholangiocyte-like cells. Recellularization onto porcine scaffolds was efficient and the organoids homogeneously differentiated, even showing polarization. Our porcine intrahepatic cholangiocyte system, combined with porcine liver scaffold paves the way for developing whole liver engineering in a relevant large-animal model

    Volumetric Bioprinting of Organoids and Optically Tuned Hydrogels to Build Liver-Like Metabolic Biofactories

    Get PDF
    Organ- and tissue-level biological functions are intimately linked to microscale cell–cell interactions and to the overarching tissue architecture. Together, biofabrication and organoid technologies offer the unique potential to engineer multi-scale living constructs, with cellular microenvironments formed by stem cell self-assembled structures embedded in customizable bioprinted geometries. This study introduces the volumetric bioprinting of complex organoid-laden constructs, which capture key functions of the human liver. Volumetric bioprinting via optical tomography shapes organoid-laden gelatin hydrogels into complex centimeter-scale 3D structures in under 20 s. Optically tuned bioresins enable refractive index matching of specific intracellular structures, countering the disruptive impact of cell-mediated light scattering on printing resolution. This layerless, nozzle-free technique poses no harmful mechanical stresses on organoids, resulting in superior viability and morphology preservation post-printing. Bioprinted organoids undergo hepatocytic differentiation showing albumin synthesis, liver-specific enzyme activity, and remarkably acquired native-like polarization. Organoids embedded within low stiffness gelatins (<2 kPa) are bioprinted into mathematically defined lattices with varying degrees of pore network tortuosity, and cultured under perfusion. These structures act as metabolic biofactories in which liver-specific ammonia detoxification can be enhanced by the architectural profile of the constructs. This technology opens up new possibilities for regenerative medicine and personalized drug testing

    Normothermic Ex Vivo Liver Platform Using Porcine Slaughterhouse Livers for Disease Modeling

    No full text
    Metabolic and toxic liver disorders, such as fatty liver disease (steatosis) and drug-induced liver injury, are highly prevalent and potentially life-threatening. To allow for the study of these disorders from the early stages onward, without using experimental animals, we collected porcine livers in a slaughterhouse and perfused these livers normothermically. With our simplified protocol, the perfused slaughterhouse livers remained viable and functional over five hours of perfusion, as shown by hemodynamics, bile production, indocyanine green clearance, ammonia metabolism, gene expression and histology. As a proof-of-concept to study liver disorders, we show that an infusion of free fatty acids and acetaminophen results in early biochemical signs of liver damage, including reduced functionality. In conclusion, the present platform offers an accessible system to perform research in a functional, relevant large animal model while avoiding using experimental animals. With further improvements to the model, prolonged exposure could make this model a versatile tool for studying liver diseases and potential treatments
    corecore