98 research outputs found

    MRI-based strain measurements reflect morphological changes following myocardial infarction:A study on the UK Biobank cohort

    Get PDF
    In a porcine experimental model of myocardial infarction, a localised, layer-specific, circumferential left ventricular strain metric has been shown to indicate chronic changes in ventricular function post-infarction more strongly than ejection fraction. This novel strain metric might therefore provide useful prognostic information clinically. In this study, existing clinical volume indices, global strains, and the novel, layer-specific strain were calculated for a large human cohort to assess variations in ventricular function and morphology with age, sex, and health status. Imaging and health data from the UK Biobank were obtained, including healthy volunteers and those with a history of cardiovascular illness. In total, 710 individuals were analysed and stratified by age, sex and health. Significant differences in all strain metrics were found between healthy and unhealthy populations, as well as between males and females. Significant differences in basal circumferential strain and global circumferential strain were found between healthy males and females, with males having smaller absolute values for both (all (Formula presented.) 0.001). There were significant differences in the functional variables left ventricular ejection fraction, end-systolic volume, end-systolic volume index and mid-ventricular circumferential strain between healthy and unhealthy male cohorts aged 65–74 (all (Formula presented.) 0.001). These results suggest that whilst regional circumferential strains may be useful clinically for assessing cardiovascular health, care must be taken to ensure critical values are indexed correctly to age and sex, due to the differences in these values observed here.</p

    Age-related changes in intraventricular kinetic energy:a physiological or pathological adaptation?

    Get PDF
    International audienceAging has important deleterious effects on the cardiovascular system. We sought to compare intraventricular kinetic energy (KE) in healthy subjects of varying ages with subjects with ventricular dysfunction to understand if changes in energetic momentum may predispose individuals to heart failure. Four-dimensional flow MRI was acquired in 35 healthy subjects (age: 1– 67 yr) and 10 patients with left ventricular (LV) dysfunction (age: 28 –79 yr). Healthy subjects were divided into age quartiles (1st quartile: 16 yr, 2nd quartile: 17–32 yr, 3rd quartile: 33– 48 yr, and 4th quartile: 49 – 64 yr). KE was measured in the LV throughout the cardiac cycle and indexed to ventricular volume. In healthy subjects, two large peaks corresponding to systole and early diastole occurred during the cardiac cycle. A third smaller peak was seen during late diastole in eight adults. Systolic KE (P 0.182) and ejection fraction (P 0.921) were preserved through all age groups. Older adults showed a lower early peak diastolic KE compared with children (P 0.0001) and young adults (P 0.025). Subjects with LV dysfunction had reduced ejection fraction (P 0.001) and compared with older healthy adults exhibited a similar early peak diastolic KE (P 0.142) but with the addition of an elevated KE in diastasis (P 0.029). In healthy individuals, peak diastolic KE progressively decreases with age, whereas systolic peaks remain constant. Peak diastolic KE in the oldest subjects is comparable to those with LV dysfunction. Unique age-related changes in ventric-ular diastolic energetics might be physiological or herald subclin-ical pathology

    Feasibility of simultaneous PET-MR perfusion using a novel cardiac perfusion phantom

    Get PDF
    Abstract Background PET-MR scanners are beginning to be employed for quantitative myocardial perfusion imaging. In order to examine simultaneous perfusion calculations, this work describes a feasibility study of simultaneous PET-MR of gadolinium-based contrast agent (GBCA) and PET radiotracer in a novel cardiac perfusion phantom. Results [18F]F− and GBCA were injected simultaneously into a cardiac phantom using a range of ground-truth myocardial perfusion rates of 1 to 5 ml/g/min. PET quantification of K 1 (ml/g/min) was performed using a single tissue compartment model. MR perfusion was calculated using a model-independent signal deconvolution technique. PET and MR signal traces from the phantom aorta and myocardial sections show true simultaneous PET and MR arterial input functions (AIF) and myocardial uptake respectively at each perfusion rate. Calculation of perfusion parameters showed both K 1 and h(t = 0) (PET and MR perfusion parameters respectively) to be linearly related with the ground truth perfusion rate (P T ), and also linearly related to each other (R2 = 0.99). The highest difference in perfusion values between K 1 and P T was 16% at 1 ml/g/min, and the mean difference for all other perfusion rates was <3%. Conclusions The perfusion phantom allows accurate and reproducible simulation of the myocardial kinetics for simultaneous PET-MR imaging, and may find use in protocol design and development of PET-MR based quantification techniques and direct comparison of quantification of the two modalities

    A hall plate based instrument to measure the snapback in the Large Hadron Collider superconducting dipole magnets

    Get PDF
    The decay and snapback of the magnetic field multipoles in superconducting particle accelerators like the Large Hadron Collider (LHC) could result in a significant particle beam loss unless adequately compensated. Whilst standard instrumentation used to measure the field quality of the superconducting magnets is good enough to measure the harmonic decay, it is not fast enough to measure the snapback. Therefore, a state of the art instrument was recently developed at CERN to measure the most important harmonics with a high measurement frequency and hence improve the understanding of the snapback phenomenon. In this paper we describe the instrument's principle of operation, its mechanical arrangement, its compensation system and its digital acquisition system. We also compare the performance of two different techniques implemented to achieve the necessary measurement resolution of 6 orders of magnitude lower than the main superimposed dipole field.peer-reviewe

    Comparison of the within-reader and inter-vendor agreement of left ventricular circumferential strains and volume indices derived from cardiovascular magnetic resonance imaging

    Get PDF
    PurposeVolume indices and left ventricular ejection fraction (LVEF) are routinely used to assess cardiac function. Ventricular strain values may provide additional diagnostic information, but their reproducibility is unclear. This study therefore compares the repeatability and reproducibility of volumes, volume fraction, and regional ventricular strains, derived from cardiovascular magnetic resonance (CMR) imaging, across three software packages and between readers.MethodsSeven readers analysed 16 short-axis CMR stacks of a porcine heart. Endocardial contours were manually drawn using OsiriX and Simpleware ScanIP and repeated in both softwares. The images were also contoured automatically in Circle CVI42. Endocardial global, apical, mid-ventricular, and basal circumferential strains, as well as end-diastolic and end-systolic volume and LVEF were compared.ResultsBland-Altman analysis found systematic biases in contour length between software packages. Compared to OsiriX, contour lengths were shorter in both ScanIP (-1.9 cm) and CVI42 (-0.6 cm), causing statistically significant differences in end-diastolic and end-systolic volumes, and apical circumferential strain (all pConclusionOsiriX and CVI42 gave consistent results for all strain and volume metrics, with no statistical differences found between OsiriX and ScanIP for mid-ventricular, global or basal strains, or left ventricular ejection fraction. However, volumes were influenced by the choice of contouring software, suggesting care should be taken when comparing volumes across different software

    Microvascular ischemia in hypertrophic cardiomyopathy:new insights from high-resolution combined quantification of perfusion and late gadolinium enhancement

    Get PDF
    BACKGROUND: Microvascular ischemia is one of the hallmarks of hypertrophic cardiomyopathy (HCM) and has been associated with poor outcome. However, myocardial fibrosis, seen on cardiovascular magnetic resonance (CMR) as late gadolinium enhancement (LGE), can be responsible for rest perfusion defects in up to 30 % of patients with HCM, potentially leading to an overestimation of the ischemic burden. We investigated the effect of left ventricle (LV) scar on the total LV ischemic burden using novel high-resolution perfusion analysis techniques in conjunction with LGE quantification. METHODS: 30 patients with HCM and unobstructed epicardial coronary arteries underwent CMR with Fermi constrained quantitative perfusion analysis on segmental and high-resolution data. The latter were corrected for the presence of fibrosis on a pixel-by-pixel basis. RESULTS: High-resolution quantification proved more sensitive for the detection of microvascular ischemia in comparison to segmental analysis. Areas of LGE were associated with significant reduction of myocardial perfusion reserve (MPR) leading to an overestimation of the total ischemic burden on non-corrected perfusion maps. Using a threshold MPR of 1.5, the presence of LGE caused an overestimation of the ischemic burden of 28 %. The ischemic burden was more severe in patients with fibrosis, also after correction of the perfusion maps, in keeping with more severe disease in this subgroup. CONCLUSIONS: LGE is an important confounder in the assessment of the ischemic burden in patients with HCM. High-resolution quantitative analysis with LGE correction enables the independent evaluation of microvascular ischemia and fibrosis and should be used when evaluating patients with HCM

    Impact of COVID-19 pandemic on characteristics, extent and trends in child maltreatment in 34 Euro-CAN COST Action countries: a scoping review protocol.

    Get PDF
    Introduction While the factors commonly associated with an increased risk of child maltreatment (CM) were found to be increased during COVID-19, reports of actual maltreatment showed varying trends. Similarly, evidence regarding the impact of COVID-19 on CM within the European Cooperation on Science and Technology and Network Collaborative (COST) Action countries remains inconsistent. This scoping review aims to explore the extent and nature of evidence pertaining to CM within the countries affiliated with the Child Abuse and Neglect in Europe Action Network (Euro-CAN), funded by the COST. Methods and analysis Key electronic databases were searched to identify eligible papers, reports and other material published between January 2020 and April 2023: PubMed, EMBASE, PsycINFO, Social Policy and Practice, Scopus and Web of Science. To cover the breadth of evidence, a systematic and broad search strategy was applied using a combination of keywords and controlled vocabulary for four concepts: children, maltreatment, COVID-19 and Euro-CAN countries, without restrictions on study design or language. Grey literature was searched in OpenGrey and Google Scholar. Two reviewers will independently screen full-text publications for eligibility and undertake data extraction, using a customised grid. The screening criteria and data charting will be piloted by the research team.The Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) extension for scoping reviews will be followed to present the results. Results will be summarised in a tabular form and narratively. Ethics and dissemination This review will identify and summarise publicly available data, without requiring ethical approval. The findings will be disseminated to the Euro-CAN Network and reported to the COST Association. They will also be published in a peer-reviewed journal. This protocol is registered on Open Science Framework
    • …
    corecore