36 research outputs found

    Alternatives to Student Outbound Mobility-Improving Students' Cultural Competency Skills Online to Improve Global Health Without Travel.

    Get PDF
    INTRODUCTION: Student outbound mobility is a major element in internationalization of medical education and global health education. However, this approach is often criticized, as it is inherently inequitable. Internationalization at home is a newer concept that aims to provide students with international skills and experiences without exchange travel. We report detailed outcomes of an international online program during the COVID-19 pandemic, which aimed to include acquisition of cultural awareness and competency-similar to what the students would have obtained if they had travelled abroad. METHOD: Sixty-eight students from 12 international universities participated in international small peer group collaborative work, and online networking. Perceived improvement of cultural competency using Likert scale and open-ended questions was used as a measure of success. Furthermore, students' definition of cultural competency in the different countries was obtained. RESULTS: Students improved their cultural competency skills. Data analysis supported statistically significant improvement of the above skills after the program, in comparison to the start of the program. DISCUSSION: Internationalization of medical education can be achieved at home-via structured online peer exchanges-and can provide students with intercultural skills and networking opportunities that are typically achieved via international in-person travel. The above represents a socially just and equitable way to reach all students and can result in improvement of their cultural competency, preparing them for their work in global health, and thereby resulting in improvement of global health. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s40670-021-01332-9

    Mid-term Outcomes of Stent Assisted Balloon Induced Intimal Disruption and Relamination in Aortic Dissection Repair (STABILISE) in Acute Type B Aortic Dissection

    No full text
    International audienceObjectives: This article reports mid-term results of 41 patients treated by the stent assisted balloon induced intimal disruption and relamination (STABILISE) technique for acute type B aortic dissection.Methods: Between November 2011 and November 2017, 41 patients (10 male; median age 50 years) underwent proximal descending aortic stent grafting plus stent assisted balloon induced intimal disruption of the thoraco-abdominal aorta for acute type B aortic dissection. Serial computed tomography angiography was used to assess aortic remodelling.Results: There were no intra-procedural complications. Fifteen branch arteries supplied by the false lumen were stented (9% of the visceral branch arteries). The thirty day incidence of death, stroke, and paralysis/visceral ischaemia was 2% (n = 1), 0%, 5% (n = 2), and 2% (n = 1) respectively. During a median follow up of 12 months (range 1–168) eight patients (20%) required re-intervention. Primary visceral stent patency was 93% (n = 14). No aortic related deaths occurred. On the most recent computed tomography angiogram, complete false lumen obliteration and aortic remodelling was obtained in all patients at the thoraco-abdominal level, and in 39% (n = 16) at the unstented infrarenal aorto-iliac level. The maximum aortic diameter increased in only two patients (5%) at the unstented infrarenal level.Conclusion: To obtain immediate and durable thoraco-abdominal aortic remodelling in acute type B dissections, the STABILISE technique is safe and reproducible while not compromising the patency of collateral branches

    Stent-assisted balloon-induced intimal disruption and relamination of distal remaining aortic dissection after acute DeBakey type I repair

    No full text
    International audienceOBJECTIVES:Surgical repair in patients with acute DeBakey type I aortic dissection (ADIAD) achieves good short-term results, but in several patients the false lumen remains patent in the descending aorta because of distal intimal tears with persisting risk for distal aneurismal evolution. We report the short- and mid-term outcomes of the stent-assisted balloon-induced intimal disruption and relamination of aortic dissection (STABILISE) technique for the 16 first patients treated for a residual dissection of the descending thoracic aorta after repaired ADIAD.METHODS:We reviewed all patients treated with STABILISE for a remaining distal thoracoabdominal aortic dissection after ADIAD repair.RESULTS:From March 2016 to March 2018, 16 patients with previous surgery for ADIAD underwent the STABILISE procedure during the same hospitalization in a second-stage procedure to extend the repair within the descending thoracic aorta. The median age was 56 years (range, 43-65 years). Indication for the STABILISE procedure was persisting false lumen patency within the thoracic descending aorta associated with malperfusion symptoms in 13 patients and associated with dissecting aneurysm of the descending thoracic aorta >40 mm in 3 patients. Technical success was achieved in 100%. Eight (12.5%) renal arteries required stenting during the procedure. In-hospital mortality was 6% (n = 1). There was no stroke, spinal cord ischemia, ischemic colitis, or renal failure requiring dialysis. Median length of follow-up was 8 months (range, 3-24 months). One patient developed a proximal type 1 endoleak in the arch and required reintervention for proximal extension of the stent graft in zone 2. The primary visceral patency rate was 100%. There were no late deaths reported. At last computed tomography scan, all patients had complete aortic remodeling of the treated thoracoabdominal aorta with no aortic enlargement.CONCLUSIONS:The STABILISE technique, in patients with remaining distal thoracoabdominal aortic dissection at the acute stage of a type A repair, allowed an immediate remodeling of the thoracoabdominal aorta, which should improve their long-term outcomes in terms of aortic-related events

    Abdominal Aortic Aneurysm Volumetric Evaluation During Mid-term Follow-Up After Endovascular Sealing Using the Nellixâ„¢ Device

    No full text
    Objectives: To analyze the volumetric evolution of abdominal aortic aneurysms after endovascular sealing (EVAS) with the Nellix™ device during follow-up. Methods: Patients who underwent elective EVAS in our institution in 2014 and 2015 were retrospectively reviewed. Preoperative, postoperative and 1-year scans were processed. A custom software was conceived to assess semi-automated measurements of the aneurysm sac and the endograft sizes including volume, maximum diameter, sectional area and perimeter. Thrombus volume, aneurysm length, mean distance between the stents inside the polymer-filled sacs and endograft migration were also estimated. Manual maximum diameters were measured for comparison. Inter and intra-observer variability of the proposed semi-automated method was evaluated. Results: Pre-EVAS, post-EVAS and last follow-up scans of 12 patients were finally analyzed during a mean follow-up of 17 ± 5 months. No endograft migration or endoleak were detected. During follow-up, aneurysm volume and perimeter slightly increased compared to post-EVAS scans (+ 1 and + 5%, respectively, p < 0.05). A systematic 6% enlargement of the endobag volume was also observed (range 1–15 mL, p < 0.001). Endobag maximum diameter, area and perimeter increased 4, 8, and 8%, respectively (all p < 0.01). Mean plane-by-plane distance between stents increased 4% (p < 0.05). Mean thrombus volume did not change during follow-up, although a high variability was observed. Aneurysm and thrombus volume changes were highly correlated (r = 0.93, p < 0.001). No associations were observed between aneurysm and endobag volume changes. Intra- and inter-observer variability was below 1.7 and 2.4% for diameter and volume measurements, respectively. The automated measurements of post-EVAS aneurysm diameter and volume were higher than preoperative (p < 0.05). Maximum diameters measured manually did not differ between scans. Conclusion: Small aneurysm volume enlargement detected during a mid-term follow-up was associated with thrombus size change, whereas systematic endograft expansion resulted independent from the aortic growth. Volumetric measurements using a semi-automated method could quantify small changes in aneurysm, endograft and thrombus sizes not detected by manually defined maximal diameters.Fil: El Batti, Salma. Hopital Europeen Georges Pompidou; FranciaFil: Casciaro, Mariano Ezequiel. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Medicina Traslacional, Trasplante y Bioingeniería. Fundación Favaloro. Instituto de Medicina Traslacional, Trasplante y Bioingeniería; ArgentinaFil: Alsac, Jean Marc. Hopital Europeen Georges Pompidou; FranciaFil: Latremouille, Christian. Hopital Europeen Georges Pompidou; FranciaFil: Julia, Pierre. Hopital Europeen Georges Pompidou; FranciaFil: Mousseaux, Elie. Hopital Europeen Georges Pompidou; FranciaFil: Craiem, Damian. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Medicina Traslacional, Trasplante y Bioingeniería. Fundación Favaloro. Instituto de Medicina Traslacional, Trasplante y Bioingeniería; Argentin
    corecore