11 research outputs found

    Reading without central vision:effects of text spacing on reading in patients with macular disease

    Get PDF
    Abstract: Loss of central vision caused by age-related macular degeneration (AMD) is a problem affecting increasingly large numbers of people within the ageing population. AMD is the leading cause of blindness in the developed world, with estimates of over 600,000 people affected in the UK . Central vision loss can be devastating for the sufferer, with vision loss impacting on the ability to carry out daily activities. In particular, inability to read is linked to higher rates of depression in AMD sufferers compared to age-matched controls. Methods to improve reading ability in the presence of central vision loss will help maintain independence and quality of life for those affected. Various attempts to improve reading with central vision loss have been made. Most textual manipulations, including font size, have led to only modest gains in reading speed. Previous experimental work and theoretical arguments on spatial integrative properties of the peripheral retina suggest that ‘visual crowding’ may be a major factor contributing to inefficient reading. Crowding refers to the phenomena in which juxtaposed targets viewed eccentrically may be difficult to identify. Manipulating text spacing of reading material may be a simple method that reduces crowding and benefits reading ability in macular disease patients. In this thesis the effect of textual manipulation on reading speed was investigated, firstly for normally sighted observers using eccentric viewing, and secondly for observers with central vision loss. Test stimuli mimicked normal reading conditions by using whole sentences that required normal saccadic eye movements and observer comprehension. Preliminary measures on normally-sighted observers (n = 2) used forced-choice procedures in conjunction with the method of constant stimuli. Psychometric functions relating the proportion of correct responses to exposure time were determined for text size, font type (Lucida Sans and Times New Roman) and text spacing, with threshold exposure time (75% correct responses) used as a measure of reading performance. The results of these initial measures were used to derive an appropriate search space, in terms of text spacing, for assessing reading performance in AMD patients. The main clinical measures were completed on a group of macular disease sufferers (n=24). Firstly, high and low contrast reading acuity and critical print size were measured using modified MNREAD test charts, and secondly, the effect of word and line spacing was investigated using a new test, designed specifically for this study, called the Equal Readability Passages (ERP) test. The results from normally-sighted observers were in close agreement with those from the group of macular disease sufferers. Results show that: (i) optimum reading performance was achieved when using both double line and double word spacing; (ii) the effect of line spacing was greater than the effect of word spacing (iii) a text size of approximately 0.85o is sufficiently large for reading at 5o eccentricity. In conclusion, the results suggest that crowding is detrimental to reading with peripheral vision, and its effects can be minimized with a modest increase in text spacing

    Enhanced text spacing improves reading performance in individuals with macular disease

    Get PDF
    The search by many investigators for a solution to the reading problems encountered by individuals with no central vision has been long and, to date, not very fruitful. Most textual manipulations, including font size, have led to only modest gains in reading speed. Previous work on spatial integrative properties of peripheral retina suggests that 'visual crowding' may be a major factor contributing to inefficient reading. Crowding refers to the fact that juxtaposed targets viewed eccentrically may be difficult to identify. The purpose of this study was to assess the combined effects of line spacing and word spacing on the ability of individuals with age-related macular degeneration (ARMD) to read short passages of text that were printed with either high (87.5%) or low contrast (17.5%) letters. Low contrast text was used to avoid potential ceiling effects and to mimic a possible reduction in letter contrast with light scatter from media opacities. For both low and high contrast text, the fastest reading speeds we measured were for passages of text with double line and double word spacing. In comparison with standard single spacing, double word/line spacing increased reading speed by approximately 26% with high contrast text (p < 0.001), and by 46% with low contrast text (p < 0.001). In addition, double line/word spacing more than halved the number of reading errors obtained with single spaced text. We compare our results with previous reading studies on ARMD patients, and conclude that crowding is detrimental to reading and that its effects can be reduced with enhanced text spacing. Spacing is particularly important when the contrast of the text is reduced, as may occur with intraocular light scatter or poor viewing conditions. We recommend that macular disease patients should employ double line spacing and double-character word spacing to maximize their reading efficiency. © 2013 Blackmore-Wright et al

    Effect of word spacing with high contrast text.

    No full text
    <p>Reading speed (wpm) for single- versus double-character word spacing (bottom panels) and single- versus triple-character word spacing (top panels) for text passages with single, double or triple line spacing. Results shown are for reading text with a letter contrast of 87.5%.The individual data points in each panel show the results for each participant; the diagonal line in each panel is the ‘line of no effect’.</p

    Effect of word spacing with low contrast text.

    No full text
    <p>Reading speed (number of correctly-read words per minute, wpm) for single- versus double-character word spacing (bottom panels) and single- versus triple-character word spacing (top panels) for text passages with single, double or triple line spacing. Results shown are for reading text with a Michelson letter contrast of 17.5%.The individual data points in each panel show the results for each participant; the diagonal line in each panel is the ‘line of no effect’.</p

    ILC Reference Design Report Volume 1 - Executive Summary

    No full text
    The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization.The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization

    ILC Reference Design Report Volume 4 - Detectors

    No full text
    This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise the needed performance, and ongoing detector R&D is addressing the outstanding technological issues. Two such detectors, operating in push-pull mode, perfectly instrument the ILC interaction region, and access the full potential of ILC physics.This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise the needed performance, and ongoing detector R&D is addressing the outstanding technological issues. Two such detectors, operating in push-pull mode, perfectly instrument the ILC interaction region, and access the full potential of ILC physics

    ILC Reference Design Report Volume 3 - Accelerator

    No full text
    The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2 s^-1. The complex includes a polarized electron source, an undulator-based positron source, two 6.7 km circumference damping rings, two-stage bunch compressors, two 11 km long main linacs and a 4.5 km long beam delivery system. This report is Volume III (Accelerator) of the four volume Reference Design Report, which describes the design and cost of the ILC.The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2 s^-1. The complex includes a polarized electron source, an undulator-based positron source, two 6.7 km circumference damping rings, two-stage bunch compressors, two 11 km long main linacs and a 4.5 km long beam delivery system. This report is Volume III (Accelerator) of the four volume Reference Design Report, which describes the design and cost of the ILC
    corecore