36 research outputs found

    Diagnostic Value of DCE-MRI for Differentiating Malignant Adnexal Masses Compared with Contrast-enhanced-T1WI

    Get PDF
    Purpose: To compare the diagnostic performance of dynamic contrast-enhanced-MR (DCE-MR) and delayed contrast-enhanced (CE)-MRI added to unenhanced MRI, including diffusion weighted image (DWI) for differentiating malignant adnexal tumors, conducting a retrospective blinded image interpretation study. Methods: Data of 80 patients suspected of having adnexal tumors by ultrasonography between April 2008 and August 2018 were used for the study. All patients had undergone preoperative MRI and surgical resection at our institution. Four radiologists (two specialized in gynecological radiology and two non-specialized) were enrolled for blinded review of the MR images. A 3-point scale was used: 0 = benign, 1 = indeterminate, and 2 = malignant. Three imaging sets were reviewed: Set A, unenhanced MRI including DWI; Set B, Set A and delayed CE-T1WI; and Set C, Set A and DCE-MRI. Imaging criteria for benign and malignant tumors were given in earlier reports. The diagnostic performance of the three imaging sets of the four readers was calculated. Their areas under the curve (AUCs) were compared using the DeLong method. Results: Accuracies of Set B were 81%–88%. Those of Set C were 81%–85%. The AUCs of Set B were 0.83 and 0.89. Those of Set C were 0.81–0.86. For two readers, Set A showed lower accuracy and AUC than Set B/Set C (less than 0.80), although those were equivalent in other readers. No significant difference in AUCs was found among the three sequence sets. Intrareader agreement was moderate to almost perfect in Sets A and B, and substantial to almost perfect in Set C. Conclusion: DCE-MR showed no superiority for differentiating malignant adnexal tumors from benign tumors compared to delayed CE-T1WI with conventional MR and DWI

    Influence of LINE-Assisted Provision of Information about Human Papillomavirus and Cervical Cancer Prevention on HPV Vaccine Intention: A Randomized Controlled Trial

    Get PDF
    We conducted a prospective, randomized two-arm, parallel group, and open label trial to investigate whether the use of LINE would increase HPV vaccine intention among not completely vaccinated university students. In June 2020, we recruited students aged between 18 and 35 years from four universities in Japan. Among the 357 enrollees (female, 53%), 178 and 179 participants were randomized into the LINE and Mail groups, respectively. At baseline, within three years, vaccine intention was observed in 40% vs. 42% of participants, respectively. At the first intervention, which provided similar PDF leaflets about HPV vaccine and cervical cancer prevention, there was no significant difference in vaccine intention between the two groups. However, at the second intervention of LINE-assisted knowledge intervention for 5 days per week for 7 weeks, the LINE group had a higher proportion of vaccine intention than the no intervention group (66% vs. 44%, OR: 2.62, 95% confidence interval (CI): 1.59-4.35) in per-protocol analysis. The significance remained in the intention-to-treat analysis of multiply imputed datasets. Although LINE did not directly increase HPV vaccine intention compared to conventional posts, the LINE-assisted provision of information was effective in improving HPV vaccine intention among Japanese university and college students

    Impact of COVID-19 on cardiovascular testing in the United States versus the rest of the world

    Get PDF
    Objectives: This study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-US institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic. Background: The COVID-19 pandemic has disrupted the care of many non-COVID-19 illnesses. Reductions in diagnostic cardiovascular testing around the world have led to concerns over the implications of reduced testing for cardiovascular disease (CVD) morbidity and mortality. Methods: Data were submitted to the INCAPS-COVID (International Atomic Energy Agency Non-Invasive Cardiology Protocols Study of COVID-19), a multinational registry comprising 909 institutions in 108 countries (including 155 facilities in 40 U.S. states), assessing the impact of the COVID-19 pandemic on volumes of diagnostic cardiovascular procedures. Data were obtained for April 2020 and compared with volumes of baseline procedures from March 2019. We compared laboratory characteristics, practices, and procedure volumes between U.S. and non-U.S. facilities and between U.S. geographic regions and identified factors associated with volume reduction in the United States. Results: Reductions in the volumes of procedures in the United States were similar to those in non-U.S. facilities (68% vs. 63%, respectively; p = 0.237), although U.S. facilities reported greater reductions in invasive coronary angiography (69% vs. 53%, respectively; p < 0.001). Significantly more U.S. facilities reported increased use of telehealth and patient screening measures than non-U.S. facilities, such as temperature checks, symptom screenings, and COVID-19 testing. Reductions in volumes of procedures differed between U.S. regions, with larger declines observed in the Northeast (76%) and Midwest (74%) than in the South (62%) and West (44%). Prevalence of COVID-19, staff redeployments, outpatient centers, and urban centers were associated with greater reductions in volume in U.S. facilities in a multivariable analysis. Conclusions: We observed marked reductions in U.S. cardiovascular testing in the early phase of the pandemic and significant variability between U.S. regions. The association between reductions of volumes and COVID-19 prevalence in the United States highlighted the need for proactive efforts to maintain access to cardiovascular testing in areas most affected by outbreaks of COVID-19 infection

    Metastatic basal cell carcinoma of buccal mucosa : a report of a rare case

    No full text
    Background Basal cell carcinoma (BCC) is the most common cancer worldwide. Most of BCCs can be detected in the early stages and are generally well controlled with local resection. Despite the high incidence of BCC, metastasis is rarely observed. Metastatic BCCs generally have an aggressive phenotype and are refractory to conventional treatment. Case presentation We describe a rare case of BCC in which a series of local relapses culminated in metastasis into the oral cavity 10 years after the first diagnosis of cutaneous BCC. We performed surgical resection and postoperative radiotherapy in this patient; 11 months after the final course of radiotherapy, the BCC remains stable, and the patient continues to be monitored regularly. Conclusions Because metastatic BCC is refractory to current treatment and difficult to control, his treatment history and the pathohistological features of BCC had to be considered in posttreatment planning

    Feasibility study of glass dosimeter postal dosimetry audit of high-energy radiotherapy photon beams

    No full text
    INTRODUCTION: \nThe characteristics of a glass dosimeter were investigated for its potential use as a tool for postal dose audits. Reproducibility, energy dependence, field size and depth dependence were compared to those of a thermoluminescence dosimeter (TLD), which has been the major tool for postal dose audits worldwide.\nMATERIALS AND METHODS: \nA glass dosimeter, GD-302M (Asahi Techno Glass Co.) and a TLD, TLD-100 chip (Harshaw Co.) were irradiated with gamma-rays from a (60)Co unit and X-rays from a medical linear accelerator (4, 6, 10 and 20 MV).\nRESULTS: \nThe dosimetric characteristics of the glass dosimeter were almost equivalent to those of the TLD, in terms of utility for dosimetry under the reference condition, which is a 10 x 10 cm(2) field and 10 cm depth. Because of its reduced fading, compared to the TLD, and easy quality control with the ID number, the glass dosimeter proved to be a suitable tool for postal dose audits. Then, we conducted postal dose surveys of over 100 facilities and got good agreement, with a standard deviation of about 1.3%.\nCONCLUSIONS: \nBased on this study, postal dose audits throughout Japan will be carried out using a glass dosimeter
    corecore