1,491 research outputs found
Noise Induced Complexity: From Subthreshold Oscillations to Spiking in Coupled Excitable Systems
We study stochastic dynamics of an ensemble of N globally coupled excitable
elements. Each element is modeled by a FitzHugh-Nagumo oscillator and is
disturbed by independent Gaussian noise. In simulations of the Langevin
dynamics we characterize the collective behavior of the ensemble in terms of
its mean field and show that with the increase of noise the mean field displays
a transition from a steady equilibrium to global oscillations and then, for
sufficiently large noise, back to another equilibrium. Diverse regimes of
collective dynamics ranging from periodic subthreshold oscillations to
large-amplitude oscillations and chaos are observed in the course of this
transition. In order to understand details and mechanisms of noise-induced
dynamics we consider a thermodynamic limit of the ensemble, and
derive the cumulant expansion describing temporal evolution of the mean field
fluctuations. In the Gaussian approximation this allows us to perform the
bifurcation analysis; its results are in good agreement with dynamical
scenarios observed in the stochastic simulations of large ensembles
Impact of system parameter selection on radar sensor performance in automotive applications
The paper deals with the investigation of relevant boundary conditions to be
considered in order to operate 77/79 GHz narrow and ultra wide band
automotive radar sensors in the automotive platform and the automotive
environment
Recommended from our members
Winter 1973
Field Evaluation of Insecticides for Controlling Mole Crickets in Turf (page 3) Calculations for Turfgrass Culture II: Pesticides (6) Progress in the Control of Turfgrass Weevil, a Species of Hyperodes (9) A Look at USDA\u27s Biological Control of Insect Pests: 1888 to Present (14) Turf Bulletin Index 1970-1973 (23
Cemented vs screw-retained zirconia-based single implant reconstructions: A 3-year prospective randomized controlled clinical trial
OBJECTIVES
The objective of the present randomized clinical trial was to test whether or not the use of screw-retained all ceramic implant-borne reconstructions results in clinical, technical, and biologic outcomes similar to those obtained with cemented all ceramic reconstructions. The hypothesis was that there is no difference in clinical, technical, and biological parameters between the two types of retention.
MATERIALS AND METHODS
Forty-four patients randomly received 20 cemented reconstruction (CR) and 24 screw-retained (SR) all ceramic single crowns on two-piece dental implants with nonmatching implant-abutment junctions. All patients were recalled after crown insertion, at 6 months, 1 year, as well as at 3 years. At these visits, biological and radiographic evaluations were performed. Technical outcomes were assessed using modified USPHS (United States Public Health Service) criteria. Data were statistically analyzed with Wilcoxon-Mann-Whitney, Wilcoxon and Fisher exact tests.
RESULTS
During 3 years of follow-up, eight patients (18.2%) lost the reconstruction due to technical (6 patients, 13.6%, 2 CR and 4 SR group) or biological complications (2 patients, 4.5%, only CR group). Thirty-two subjects with 18 SR and 14 CR reconstructions attended the FU-3Y, whereas four patients (9.1%, 2 SR, 2 CR) were not available (drop-outs). Biological, technical, and radiographic outcomes did not differ significantly between the groups (P > 0.05). One implant (2.3%) was lost in the CR group. One more cemented crown (2.3%) had to be removed because of peri-implant disease. Six patients (13.6%) lost the reconstructions due to a fracture of the zirconia abutment (4 SR, 2 CR). The mean marginal bone level at 3 years was -0.4 mm (-0.5; -0.3) in group SR and - 0.4 mm (-0.6; -0.3) group CR (P = 0.864).
CONCLUSIONS
At 3 years, CR and SR exhibited similar survival technical, biological and radiographic outcomes. The rate of technical complications was high in both groups
Shoulder load during synchronous handcycling and handrim wheelchair propulsion in persons with paraplegia
Objective: To compare the shoulder load during handcycling and wheelchair propulsion under similar conditions of external power in persons with spinal cord injury. Design: Cross-sectional. Subjects: Eight men with spinal cord injury. Methods: Kinetics and kinematics were measured during handbike and wheelchair propulsion at 25, 35, 45 and 55 W on a treadmill. Shoulder load (glenohumeral contact forces, relative muscle forces) was calculated with the Delft Shoulder and Elbow Model. Results: At all power output levels, glenohumeral contact forces were significantly lower during handcycling compared with wheelchair propulsion (p < 0.001). At 55 W, the mean glenohumeral contact force was 345 N for handcycling, whereas it was 585 N for wheelchair propulsion. Also, relative muscle forces were lower during handcycling. The largest differences between handbike and wheelchair propulsion were found in the supraspinatus (4.5% vs. 20.7%), infraspinatus (3.7% vs. 16.5%) and biceps (5.0% vs. 17.7%). Conclusion: Due to continuous force application in handcycling, shoulder load was lower compared with wheelchair propulsion. Furthermore, muscles that are prone to overuse injuries were less stressed during handcycling. Therefore, handcycling may be a good alternative for outdoor mobility and may help prevent overuse injuries of the shoulder complex. © 2012 The Authors
Collapse of Flux Tubes
The dynamics of an idealized, infinite, MIT-type flux tube is followed in
time as the interior evolves from a pure gluon field to a
plasma. We work in color U(1). pair formation is evaluated
according to the Schwinger mechanism using the results of Brink and Pavel. The
motion of the quarks toward the tube endcaps is calculated by a Boltzmann
equation including collisions. The tube undergoes damped radial oscillations
until the electric field settles down to zero. The electric field stabilizes
the tube against pinch instabilities; when the field vanishes, the tube
disintegrates into mesons. There is only one free parameter in the problem,
namely the initial flux tube radius, to which the results are very sensitive.
Among various quantities calculated is the mean energy of the emitted pions.Comment: 16 pages plus 12 figures. RevTex3. DOE/ER/40427-160N9
Cost-effectiveness of CTA, MRA and DSA in patients with non-traumatic subarachnoid haemorrhage
OBJECTIVES: Intra-arterial digital subtraction angiography (DSA), magnetic resonance angiography (MRA) and computed tomographic angiography (CTA) are imaging modalities used for diagnostic work-up of non-traumatic subarachnoid haemorrhage. The aim of our study was to compare the cost-effectiveness of MRA, DSA and CTA in the first year after the bleed. METHODS: A decision model was used to calculate costs and benefits (in quality-adjusted life-years [QALYs]) that accrued to cohorts of 1,000 patients. Costs and characteristics of diagnostic tests, therapy, patients’ quality of life and associated costs were respected. The diagnostic strategy with highest QALYs and lowest costs was considered most cost-effective. RESULTS: DSA was the most effective diagnostic option, yielding on average 0.6039 QALYs (95 % CI, 0.5761–0.6327) per patient, followed by CTA 0.5983 QALYs (95 % CI, 0.5704–0.6278) and MRA 0.5947 QALYs (95 % CI, 0.5674–0.6237). Cost was lowest for DSA (39,808 €; 95 % CI, 37,182–42,663), followed by CTA (40,748 €; 95 % CI, 37,937–43,831) and MRA (41,814 €; 95 % CI, 38,730–45,146). A strategy of CTA followed by DSA if CTA was negative or coiling deemed not feasible, was as effective as DSA alone at average costs of 39,767€ (95 % CI, 36,903–42,402). CONCLUSION: A combined strategy of CTA and DSA was found to be the most cost-effective diagnostic approach. MAIN MESSAGES: • We defined a standard model for cost-effectiveness analysis in diagnostic imaging. • Comparing total 1-year health costs and benefits, CTA is superior to MRA. • A strategy of combining CTA and DSA was found to be the most cost-effective diagnostic approach
Restorative angle of zirconia restorations cemented on non-original titanium bases influences the initial marginal bone loss: 5-year results of a prospective cohort study
AIM: To assess radiographic, restorative, clinical and technical outcomes as well as patient satisfaction of directly veneered zirconia restorations cemented on non-original titanium bases over 5 years.
MATERIAL AND METHODS: Twenty-four patients with a single missing tooth in the aesthetic zone were recruited. All patients received a two-piece implant with a screw-retained veneered zirconia restoration cemented extraorally on a titanium base abutment. Marginal bone levels (MBL), marginal bone changes, technical complications, patient satisfaction and clinical parameters including probing depth, bleeding on probing and plaque index were assessed at crown delivery (baseline), at 1 year (FU-1) and 5 years (FU-5) of follow-up. To investigate the relationship between restorative angle and MBL as well as marginal bone changes (bone loss/bone gain), correlation tests and linear regression models were carried out.
RESULTS: Twenty-two patients were available for re-examination at 5 years. The mean MBL amounted to 0.54 ± 0.39 mm at baseline, and to 0.24 ± 0.35 at FU-5 (=bone gain) (p  .05). At distal sites, no correlations or associations between the restorative angle and MBL or marginal bone changes were found regardless of the time point. During the 5-year follow-up, 5 technical complications occurred, mainly within the first year and mostly chippings. All patients were entirely satisfied with their implant-supported restoration at 5 years.
CONCLUSION: Within the limitations of the present study, the restorative angle of implant-supported crowns on non-original titanium bases might influence the initial marginal bone loss but without affecting their favourable long-term clinical performance. A restorative angle of <40° may limit the initial marginal bone loss at implant-supported crowns with titanium bases
- …