10 research outputs found

    Diagnostic accuracy of the Eurotest for dementia: a naturalistic, multicenter phase II study

    No full text
    Abstract Background Available screening tests for dementia are of limited usefulness because they are influenced by the patient's culture and educational level. The Eurotest, an instrument based on the knowledge and handling of money, was designed to overcome these limitations. The objective of this study was to evaluate the diagnostic accuracy of the Eurotest in identifying dementia in customary clinical practice. Methods A cross-sectional, multi-center, naturalistic phase II study was conducted. The Eurotest was administered to consecutive patients, older than 60 years, in general neurology clinics. The patients' condition was classified as dementia or no dementia according to DSM-IV diagnostic criteria. We calculated sensitivity (Sn), specificity (Sp) and area under the ROC curves (aROC) with 95% confidence intervals. The influence of social and educational factors on scores was evaluated with multiple linear regression analysis, and the influence of these factors on diagnostic accuracy was evaluated with logistic regression. Results Sixteen neurologists recruited a total of 516 participants: 101 with dementia, 380 without dementia, and 35 who were excluded. Of the 481 participants who took the Eurotest, 38.7% were totally or functionally illiterate and 45.5% had received no formal education. Mean time needed to administer the test was 8.2+/-2.0 minutes. The best cut-off point was 20/21, with Sn = 0.91 (0.84–0.96), Sp = 0.82 (0.77–0.85), and aROC = 0.93 (0.91–0.95). Neither the scores on the Eurotest nor its diagnostic accuracy were influenced by social or educational factors. Conclusion This naturalistic and pragmatic study shows that the Eurotest is a rapid, simple and useful screening instrument, which is free from educational influences, and has appropriate internal and external validity.</p

    Diagnostic accuracy of the Eurotest for dementia: a naturalistic, multicenter phase II study

    Get PDF
    Clinical Trial, Phase II; Journal Article; Multicenter Study; Research Support, Non-U.S. Gov't; Validation Studies;BACKGROUND Available screening tests for dementia are of limited usefulness because they are influenced by the patient's culture and educational level. The Eurotest, an instrument based on the knowledge and handling of money, was designed to overcome these limitations. The objective of this study was to evaluate the diagnostic accuracy of the Eurotest in identifying dementia in customary clinical practice. METHODS A cross-sectional, multi-center, naturalistic phase II study was conducted. The Eurotest was administered to consecutive patients, older than 60 years, in general neurology clinics. The patients' condition was classified as dementia or no dementia according to DSM-IV diagnostic criteria. We calculated sensitivity (Sn), specificity (Sp) and area under the ROC curves (aROC) with 95% confidence intervals. The influence of social and educational factors on scores was evaluated with multiple linear regression analysis, and the influence of these factors on diagnostic accuracy was evaluated with logistic regression. RESULTS Sixteen neurologists recruited a total of 516 participants: 101 with dementia, 380 without dementia, and 35 who were excluded. Of the 481 participants who took the Eurotest, 38.7% were totally or functionally illiterate and 45.5% had received no formal education. Mean time needed to administer the test was 8.2+/-2.0 minutes. The best cut-off point was 20/21, with Sn = 0.91 (0.84-0.96), Sp = 0.82 (0.77-0.85), and aROC = 0.93 (0.91-0.95). Neither the scores on the Eurotest nor its diagnostic accuracy were influenced by social or educational factors. CONCLUSION This naturalistic and pragmatic study shows that the Eurotest is a rapid, simple and useful screening instrument, which is free from educational influences, and has appropriate internal and external validity.The Trans-Eurotest Study was funded by the Andalusian Regional Government (Department of Health grants 103/04 and 125/04) and by a research grant provided by Laboratorios Janssen-Cilag, Madrid, Spain.Ye

    Diagnostic accuracy of the Eurotest for dementia: a naturalistic, multicenter phase II study-1

    No full text
    <p><b>Copyright information:</b></p><p>Taken from "Diagnostic accuracy of the Eurotest for dementia: a naturalistic, multicenter phase II study"</p><p>BMC Neurology 2006;6():15-15.</p><p>Published online 10 Apr 2006</p><p>PMCID:PMC1459198.</p><p>Copyright © 2006 Carnero-Pardo et al; licensee BioMed Central Ltd.</p>cy Test (dashed line) in identifying dementi

    Diagnostic accuracy of the Eurotest for dementia: a naturalistic, multicenter phase II study-0

    No full text
    <p><b>Copyright information:</b></p><p>Taken from "Diagnostic accuracy of the Eurotest for dementia: a naturalistic, multicenter phase II study"</p><p>BMC Neurology 2006;6():15-15.</p><p>Published online 10 Apr 2006</p><p>PMCID:PMC1459198.</p><p>Copyright © 2006 Carnero-Pardo et al; licensee BioMed Central Ltd.</p>osis of dementi

    Estudio multicéntrico nacional sobre pancreatectomías totales

    No full text

    COVID-19-related mortality in kidney transplant and dialysis patients: Results of the ERACODA collaboration

    No full text
    Background. Patients on kidney replacement therapy comprise a vulnerable population and may be at increased risk of death from coronavirus disease 2019 (COVID-19). Currently, only limited data are available on outcomes in this patient population. Methods. We set up the ERACODA (European Renal Association COVID-19 Database) database, which is specifically designed to prospectively collect detailed data on kidney transplant and dialysis patients with COVID-19. For this analysis, patients were included who presented between 1 February and 1 May 2020 and had complete information available on the primary outcome parameter, 28-day mortality. Results. Of the 1073 patients enrolled, 305 (28%) were kidney transplant and 768 (72%) dialysis patients with a mean age of 60 6 13 and 67 6 14 years, respectively. The 28-day probability of death was 21.3% [95% confidence interval (95% CI) 14.3\u201330.2%] in kidney transplant and 25.0% (95% CI 20.2\u201330.0%) in dialysis patients. Mortality was primarily associated with advanced age in kidney transplant patients, and with age and frailty in dialysis patients. After adjusting for sex, age and frailty, in-hospital mortality did not significantly differ between transplant and dialysis patients [hazard ratio (HR) 0.81, 95% CI 0.59\u20131.10, P \ubc 0.18]. In the subset of dialysis patients who were a candidate for transplantation (n \ubc 148), 8 patients died within 28 days, as compared with 7 deaths in 23 patients who underwent a kidney transplantation &lt;1 year before presentation (HR adjusted for sex, age and frailty 0.20, 95% CI 0.07\u20130.56, P &lt; 0.01). Conclusions. The 28-day case-fatality rate is high in patients on kidney replacement therapy with COVID-19 and is primarily driven by the risk factors age and frailty. Furthermore, in the first year after kidney transplantation, patients may be at increased risk of COVID-19-related mortality as compared with dialysis patients on the waiting list for transplantation. This information is important in guiding clinical decision-making, and for informing the public and healthcare authorities on the COVID-19-related mortality risk in kidney transplant and dialysis patients

    Chemometrics

    No full text
    corecore