47 research outputs found

    Clinical Applications for Diffusion MRI and Tractography of Cranial Nerves Within the Posterior Fossa: A Systematic Review

    Get PDF
    Objective: This paper presents a systematic review of diffusion MRI (dMRI) and tractography of cranial nerves within the posterior fossa. We assess the effectiveness of the diffusion imaging methods used and examine their clinical applications.Methods: The Pubmed, Web of Science and EMBASE databases were searched from January 1st 1997 to December 11th 2017 to identify relevant publications. Any study reporting the use of diffusion imaging and/or tractography in patients with confirmed cranial nerve pathology was eligible for selection. Study quality was assessed using the Methodological Index for Non-Randomized Studies (MINORS) tool.Results: We included 41 studies comprising 16 studies of patients with trigeminal neuralgia (TN), 22 studies of patients with a posterior fossa tumor and three studies of patients with other pathologies. Most acquisition protocols used single-shot echo planar imaging (88%) with a single b-value of 1,000 s/mm2 (78%) but there was significant variation in the number of gradient directions, in-plane resolution, and slice thickness between studies. dMRI of the trigeminal nerve generated interpretable data in all cases. Analysis of diffusivity measurements found significantly lower fractional anisotropy (FA) values within the root entry zone of nerves affected by TN and FA values were significantly lower in patients with multiple sclerosis. Diffusivity values within the trigeminal nerve correlate with the effectiveness of surgical treatment and there is some evidence that pre-operative measurements may be predictive of treatment outcome. Fiber tractography was performed in 30 studies (73%). Most studies evaluating fiber tractography involved patients with a vestibular schwannoma (82%) and focused on generating tractography of the facial nerve to assist with surgical planning. Deterministic tractography using diffusion tensor imaging was performed in 93% of cases but the reported success rate and accuracy of generating fiber tracts from the acquired diffusion data varied considerably.Conclusions: dMRI has the potential to inform our understanding of the microstructural changes that occur within the cranial nerves in various pathologies. Cranial nerve tractography is a promising technique but new avenues of using dMRI should be explored to optimize and improve its reliability

    Cochlear implant outcomes in patients with Meniere's disease: a large case series

    Get PDF
    OBJECTIVE: To perform a matched cohort study to assess whether patients with Meniere's Disease (MD) require more intensive auditory rehabilitation following cochlear implantation (CI) and identify factors that may affect outcomes in patients with MD. METHODS: A retrospective case review was performed. MD and control patients were matched for age, biological sex, implant manufacturer and electrode design. Outcomes measured were speech scores, number of visits to audiology department following switch-on, and post-operative active MD. RESULTS: Forty consecutive implanted MD patients were identified between May 1993 and May 2019. Patients with active MD following CI required significantly more visits to the audiology department compared to controls (P < 0.01) and patients who had inactive MD post-operatively (P < 0.01). However, in MD patients, active MD was less likely following CI (P = 0.03). In patients who continued to experience active MD post-operatively, further medical and surgical ablative intervention was required to control ongoing Meniere's attacks. CONCLUSION: We present the largest case series of performance outcomes in CI patients with MD. Although speech outcomes in MD patients are comparable to controls, patients with active MD pre-operatively are more likely to experience variation in CI performance requiring a prolonged period of auditory rehabilitation compared to inactive preoperative MD

    Diffusion MRI of the facial-vestibulocochlear nerve complex: a prospective clinical validation study

    Get PDF
    Objectives: Surgical planning of vestibular schwannoma surgery would benefit greatly from a robust method of delineating the facial-vestibulocochlear nerve complex with respect to the tumour. This study aimed to optimise a multi-shell readout-segmented diffusion-weighted imaging (rs-DWI) protocol and develop a novel post-processing pipeline to delineate the facial-vestibulocochlear complex within the skull base region, evaluating its accuracy intraoperatively using neuronavigation and tracked electrophysiological recordings./ Methods: In a prospective study of five healthy volunteers and five patients who underwent vestibular schwannoma surgery, rs-DWI was performed and colour tissue maps (CTM) and probabilistic tractography of the cranial nerves were generated. In patients, the average symmetric surface distance (ASSD) and 95% Hausdorff distance (HD-95) were calculated with reference to the neuroradiologist-approved facial nerve segmentation. The accuracy of patient results was assessed intraoperatively using neuronavigation and tracked electrophysiological recordings./ Results: Using CTM alone, the facial-vestibulocochlear complex of healthy volunteer subjects was visualised on 9/10 sides. CTM were generated in all 5 patients with vestibular schwannoma enabling the facial nerve to be accurately identified preoperatively. The mean ASSD between the annotators’ two segmentations was 1.11 mm (SD 0.40) and the mean HD-95 was 4.62 mm (SD 1.78). The median distance from the nerve segmentation to a positive stimulation point was 1.21 mm (IQR 0.81–3.27 mm) and 2.03 mm (IQR 0.99–3.84 mm) for the two annotators, respectively./ Conclusions: rs-DWI may be used to acquire dMRI data of the cranial nerves within the posterior fossa./ Clinical relevance statement: Readout-segmented diffusion-weighted imaging and colour tissue mapping provide 1–2 mm spatially accurate imaging of the facial-vestibulocochlear nerve complex, enabling accurate preoperative localisation of the facial nerve. This study evaluated the technique in 5 healthy volunteers and 5 patients with vestibular schwannoma./ Key Points: • Readout-segmented diffusion-weighted imaging (rs-DWI) with colour tissue mapping (CTM) visualised the facial-vestibulocochlear nerve complex on 9/10 sides in 5 healthy volunteer subjects./ • Using rs-DWI and CTM, the facial nerve was visualised in all 5 patients with vestibular schwannoma and within 1.21–2.03 mm of the nerve’s true intraoperative location./ • Reproducible results were obtained on different scanners

    Generating Operative Workflows for Vestibular Schwannoma Resection: A Two-Stage Delphi's Consensus in Collaboration with the British Skull Base Society. Part 2: The Translabyrinthine Approach

    Get PDF
    Objective An operative workflow systematically compartmentalizes operations into hierarchal components of phases, steps, instrument, technique errors, and event errors. Operative workflow provides a foundation for education, training, and understanding of surgical variation. In this Part 2, we present a codified operative workflow for the translabyrinthine approach to vestibular schwannoma resection. Methods A mixed-method consensus process of literature review, small-group Delphi's consensus, followed by a national Delphi's consensus was performed in collaboration with British Skull Base Society (BSBS). Each Delphi's round was repeated until data saturation and over 90% consensus was reached. Results Seventeen consultant skull base surgeons (nine neurosurgeons and eight ENT [ear, nose, and throat]) with median of 13.9 years of experience (interquartile range: 18.1 years) of independent practice participated. There was a 100% response rate across both the Delphi rounds. The translabyrinthine approach had the following five phases and 57 unique steps: Phase 1, approach and exposure; Phase 2, mastoidectomy; Phase 3, internal auditory canal and dural opening; Phase 4, tumor debulking and excision; and Phase 5, closure. Conclusion We present Part 2 of a national, multicenter, consensus-derived, codified operative workflow for the translabyrinthine approach to vestibular schwannomas. The five phases contain the operative, steps, instruments, technique errors, and event errors. The codified translabyrinthine approach presented in this manuscript can serve as foundational research for future work, such as the application of artificial intelligence to vestibular schwannoma resection and comparative surgical research

    Comparison of the benefits of cochlear implantation versus contra-lateral routing of signal hearing aids in adult patients with single-sided deafness: study protocol for a prospective within-subject longitudinal trial

    Get PDF
    Background Individuals with a unilateral severe-to-profound hearing loss, or single-sided deafness, report difficulty with listening in many everyday situations despite having access to well-preserved acoustic hearing in one ear. The standard of care for single-sided deafness available on the UK National Health Service is a contra-lateral routing of signals hearing aid which transfers sounds from the impaired ear to the non-impaired ear. This hearing aid has been found to improve speech understanding in noise when the signal-to-noise ratio is more favourable at the impaired ear than the non-impaired ear. However, the indiscriminate routing of signals to a single ear can have detrimental effects when interfering sounds are located on the side of the impaired ear. Recent published evidence has suggested that cochlear implantation in individuals with a single-sided deafness can restore access to the binaural cues which underpin the ability to localise sounds and segregate speech from other interfering sounds. Methods/Design The current trial was designed to assess the efficacy of cochlear implantation compared to a contra-lateral routing of signals hearing aid in restoring binaural hearing in adults with acquired single-sided deafness. Patients are assessed at baseline and after receiving a contra-lateral routing of signals hearing aid. A cochlear implant is then provided to those patients who do not receive sufficient benefit from the hearing aid. This within-subject longitudinal design reflects the expected care pathway should cochlear implantation be provided for single-sided deafness on the UK National Health Service. The primary endpoints are measures of binaural hearing at baseline, after provision of a contra-lateral routing of signals hearing aid, and after cochlear implantation. Binaural hearing is assessed in terms of the accuracy with which sounds are localised and speech is perceived in background noise. The trial is also designed to measure the impact of the interventions on hearing- and health-related quality of life. Discussion This multi-centre trial was designed to provide evidence for the efficacy of cochlear implantation compared to the contra-lateral routing of signals. A purpose-built sound presentation system and established measurement techniques will provide reliable and precise measures of binaural hearing. Trial registration Current Controlled Trials http://www.controlled-trials.com/ISRCTN33301739 (05/JUL/2013

    A fast and reliable three-dimensional centerline tracing: application to virtual cochlear implant surgery

    No full text
    This paper presents a rapid and unsupervised three-dimensional (3D) tubular structure tracing algorithm for the detection of safe trajectories in cochlear surgery. The algorithm utilizes a generalized 3D cylinder model which offers low-order parameterization, enabling low-cost recursive directional tubular boundary analysis and derivation of tubular statistics (i.e. centerline coordinates). Unlike previous work, the proposed algorithm circumvents excessive computation per voxel while enhancing angular centerline traversing efficiency which is critical in cochlear implant surgery navigation. To accomplish this, design considerations include: 1) accurate engineering of kernels used for border analysis, 2) modifying decision-making in identifying optimal tracing angle with homogeneity criterion, 3) reducing tubular change exploratory search cost through discrete convolution analysis, and 4) a cross-section calibration engine which suppresses centerline angular deviations as well as recording a history of geometrical changes while tracing. When evaluated on synthetic imagery mimicking cochlea structural complexity and real reconstructed cochlea models, it consistently produced accurate estimates of centerline coordinates and widths-heights in the presence of noise and spatial artefacts. Validation has shown that the centerline error for the proposed algorithm is below 6 pixels and the average traced pixel performance is 92.9% of the true centerline pixels on the examined cochlea models. By restricting the image analysis to the regions of interest, the proposed algorithm performs rapid centerline tracing of the cochlea needed for real-time surgery (0.48 seconds per electrode insertion).</p

    Insertion Guidance Based on Impedance Measurements of a Cochlear Electrode Array

    Get PDF
    The cochlear implantable neuromodulator provides substantial auditory perception to those with severe or profound impaired hearing. Correct electrode array positioning in the cochlea is one of the important factors for quality hearing, and misplacement may lead to additional injury to the cochlea. Visual inspection of the progress of electrode insertion is limited and mainly relies on the surgeon's tactile skills, and there is a need to detect in real-time the electrode array position in the cochlea during insertion. The available clinical measurement presently provides very limited information. Impedance measurement may be used to assist with the insertion of the electrode array. Using computational modeling of the cochlea, and its local tissue layers merging with the associated neuromodulator electrode array parameters, the impedance variations at different insertion depths and the proximities to the cochlea walls have been analyzed. In this study, an anatomical computational model of the temporal region of a patient is used to derive the relationship between impedance variations and the electrode proximity to the cochlea wall and electrode insertion depth. The aim was to examine whether the use of electrode impedance variations can be an effective marker of electrode proximity and electrode insertion depth. The proposed anatomical model simulates the quasi-static electrode impedance variations at different selected points but at considerable computation cost. A much less computationally intensive geometric model (~1/30) provided comparative impedance measurements with differences of <2%. Both use finite element analysis over the entire cross-section area of the scala tympani. It is shown that the magnitude of the impedance varies with both electrode insertion depth and electrode proximity to the adjacent anatomical layers (e.g., cochlea wall). In particular, there is a 1,400% increase when the electrode array is moved very close to the cochlea wall. This may help the surgeon to find the optimal electrode position within the scala tympani by observation of such impedance characteristics. The misplacement of the electrode array within the scala tympani may be eliminated by using the impedance variation metric during electrode array insertion if the results are validated with an experimental study
    corecore