68 research outputs found

    Design and simulation of a PI controller system with frequency response

    Get PDF
    It is convenient to have a minimum number of parameters that are tuned to control a system.  Proportional-integral-derivative (PID) controllers have this specification and are now daily used in a different field of application especially in industrial control system.  To get the frequency response of such controller to any disturbance signal an appropriate design technique is needed.  Here a PI controller system is implemented and simulated using NI Multisim (13.0) software. We study the frequency response of a PI controller. The results and calculations show that the designed PI controller has very fast (above than 10 kHz) response to any disturbance. We show a large match between the simulation and the experimental part. A bode plot that give us the frequency response of the system has been calculated and measured. The implemented work is important for many applications especially in the field of atomic force microscopy (AFM), scanning tunneling microscopy (STM) and other industrial control system that need fast control

    Differential Regulation of Myocardial E3 Ligases and Deubiquitinases in Ischemic Heart Failure

    Get PDF
    The pathological changes of ubiquitination and deubiquitination following myocardial infarction (MI) and chronic heart failure (CHF) have been sparsely examined. We investigated the expression of muscle-specific E3 ubiquitin ligases and deubiquitinases in MI and CHF. Therefore, mice were assigned to coronary artery ligation for 3 days or 10 weeks as well as for sham operation (each n = 10). Expression of E3 ligases (MAFBX, MURF1, CHIP, ITCH, MDM2) and deubiquitinases (A20, CYLD, UCH-L1, USP14, USP19) was determined. After MI and in CHF, the mRNA expression of MURF1, CHIP and MDM2 (all p < 0.05) was decreased. Protein expression analyses revealed that ITCH expression decreased in CHF (p = 0.01), whereas MDM2 expression increased in MI (p = 0.02) and decreased in CHF (p = 0.02). Except for USP19 mRNA expression that decreased at 3 days and 10 weeks (both p < 0.01), the expression of other deubiquitinases remained unaffected after MI and CHF. The expression of myocardial E3 ligases is differentially regulated following MI, raising the question of whether an upstream regulation exists that is activated by MI for tissue protection or whether the downregulation of E3 ligases enables myocardial hypertrophy following MI

    Everolimus-Induced Immune Effects after Heart Transplantation: A Possible Tool for Clinicians to Monitor Patients at Risk for Transplant Rejection

    Get PDF
    Background: Patients treated with an inhibitor of the mechanistic target of rapamycin (mTORI) in a calcineurin inhibitor (CNI)-free immunosuppressive regimen after heart transplantation (HTx) show a higher risk for transplant rejection. We developed an immunological monitoring tool that may improve the identification of mTORI-treated patients at risk for rejection. Methods: Circulating dendritic cells (DCs) and regulatory T cells (Tregs) were analysed in 19 mTORI- and 20 CNI-treated HTx patients by flow cytometry. Principal component and cluster analysis were used to identify patients at risk for transplant rejection. Results: The percentages of total Tregs (p = 0.02) and CD39+ Tregs (p = 0.05) were higher in mTORI-treated patients than in CNI-treated patients. The principal component analysis revealed that BDCA1+, BDCA2+ and BDCA4+ DCs as well as total Tregs could distinguish between non-rejecting and rejecting mTORI-treated patients. Most mTORI-treated rejectors showed higher levels of BDCA2+ and BDCA4+ plasmacytoid DCs and lower levels of BDCA1+ myeloid DCs and Tregs than mTORI non-rejectors. Conclusion: An mTORI-based immunosuppressive regimen induced a sufficient, tolerance-promoting reaction in Tregs, but an insufficient, adverse effect in DCs. On the basis of patient-specific immunological profiles, we established a flow cytometry-based monitoring tool that may be helpful in identifying patients at risk for rejection

    Studying of Some Characteristics and parameters of Argon Glow discharge plasma Using Hollow Anode Diameter

    Get PDF
    Hollow anode argon glow discharge plasma has been investigated experimentally at different argon gas pressure from constant discharge current. A sufficient high voltage has been applied among the electrodes to obtain breakdown. Firstly, we studied the influence of hollow anode diameter on the breakdown voltage and Paschens law. The inner diameters of hollow anodes used in our work were (10, 15, 20, 25, 30, 35, and 40) mm. Secondly under the same conditions we extended our study to measure some plasma parameters in the negative glow region using direct current argon glow discharge. The temperature and density of electrons in the negative glow were measured using double probes. From the (Ip-Vp) characteristics of double probes, we obtained plasma parameters by using computer MATLAB program. The results showed that the measured Pashence's curve closes to the well-known theoretical Pashence's law. The breakdown voltage and its minimum value decreased with increasing the hollow anode diameter. The Paschen’s curve became wide and shifted to lower pressure with increasing the diameter. The reduction area of hollow anode caused dens and luminous intensity of plasma to occur in the negative glow region. Increasing the diameter resulted in decreasing the temperature and density of electron

    Operative management and outcomes in patients with myxomas: A single-center experience

    Get PDF
    BackgroundCardiac myxoma is a rare cardiac tumor that may be asymptomatic or can cause embolization or intracardiac obstruction, leading to heart failure, sudden cardiac death, and arrhythmia. This study aims to report an 11-year experience of a single center in the management of cardiac myxoma.MethodThis study is a single-center retrospective case series. Eighty cases of cardiac myxoma were collected in Ibn Albitar's specialized center for cardiac surgery. Transthoracic echocardiography was used to make the preoperative diagnosis in all patients. The surgeries were undertaken through the standard approach of a median sternotomy. All four cardiac chambers were thoroughly explored for additional myxomas. The major objective of the operations was complete tumor resection.ResultThe mean age of the patients was 46.3 years. Females (67.5%) were predominant over males (32.5%). Shortness of breath was the most common symptom (86.25%). The left atrium was the most affected site (83.75%), followed by the right atrium (13.75%). Coronary artery bypass grafting was required as the secondary or associated intervention in 19 (23.75%) cases. The recurrence rate was 11.25%, with a mortality rate of 3.75%.ConclusionRecurrence and tumor embolism are risks of surgical intervention for myxoma. Good preparation using transthoracic echocardiography as a diagnostic tool and standard median sternotomy to complete resection of the tumors can decrease the rate of recurrence, embolism, and even mortality

    Impact of a surgical approach for implantation of durable left ventricular assist devices in patients on extracorporeal life support

    Get PDF
    Background The aim of this study was to evaluate the impact of the surgical approach on the postoperative outcome in patients who underwent left ventricular assist device (LVAD) implantation after having received veno-arterial extracorporeal life support (va-ECLS) using data from a European registry (ECLS-VAD). Five hundred and thirty-one patients were included. Methods A propensity score-adjusted outcome analysis was performed, resulting in 324 patients in the full sternotomy (FS) group and 39 in the less invasive surgery (LIS) group. Results The surgery lasted in median 236 min in the FS group versus 263 min in the LIS group (p = 0.289). The median chest tube output during the first 24 h was similar in both groups. Patients who underwent implantation with an FS required more blood products during the first 24 postoperative hours (median 16 vs. 12, p = 0.033). The incidence of revision due to bleeding was also higher (35.5 vs. 15.4%, p = 0.016). A temporary postoperative right ventricular assist device was necessary in 45.1 (FS) versus 23.1% (LIS) of patients, respectively (p = 0.067). No stroke occurred in the LIS group during the first 30 days after surgery (7.4% in the FS group). The incidence of stroke and of renal, hepatic, and respiratory failure during the follow-up was similar in both groups. The 30-day and one-year survival were similar in both groups. Conclusion LIS for implantation of a durable LVAD in patients on va-ECLS implanted for cardiogenic shock is associated with less revision due to bleeding, less administration of blood products and absence of perioperative stroke, with no impact on survival

    HVAD to HeartMate 3 left ventricular assist device exchange: Best practices recommendations

    Get PDF
    The HeartWare HVAD System (Medtronic) is a durable implantable left ventricular assist device that has been implanted in approximately 20,000 patients worldwide for bridge to transplant and destination therapy indications. In December 2020, Medtronic issued an Urgent Medical Device Communication informing clinicians of a critical device malfunction in which the HVAD may experience a delay or failure to restart after elective or accidental discontinuation of pump operation. Moreover, evolving retrospective comparative effectiveness studies of patients supported with the HVAD demonstrated a significantly higher risk of stroke and all-cause mortality when compared with a newer generation of a commercially available durable left ventricular assist device. Considering the totality of this new information on HVAD performance and the availability of an alternate commercially available device, Medtronic halted the sale and distribution of the HVAD System in June 2021. The decision to remove the HVAD from commercial distribution now requires the use of the HeartMate 3 left ventricular assist system (Abbott, Inc) if a patient previously implanted with an HVAD requires a pump exchange. The goal of this document is to review important differences in the design of the HVAD and HeartMate 3 that are relevant to the medical management of patients supported with these devices, and to assess the technical aspects of an HVAD-to-HeartMate 3 exchange. This document provides the best available evidence that supports best practices

    Peripheral versus central extracorporeal membrane oxygenation for postcardiotomy shock: Multicenter registry, systematic review, and meta-analysis

    Get PDF
    BackgroundWe hypothesized that cannulation strategy in venoarterial extracorporeal membrane oxygenation (VA-ECMO) could play a crucial role in the perioperative survival of patients affected by postcardiotomy shock.MethodsBetween January 2010 and March 2018, 781 adult patients receiving VA-ECMO for postcardiotomy shock at 19 cardiac surgical centers were retrieved from the Postcardiotomy Veno-arterial Extracorporeal Membrane Oxygenation study registry. A parallel systematic review and meta-analysis (PubMed/MEDLINE, Embase, and Cochrane Library) through December 2018 was also accomplished.ResultsCentral and peripheral VA-ECMO cannulation were performed in 245 (31.4%) and 536 (68.6%) patients, respectively. Main indications for the institution VA-ECMO were failure to wean from cardiopulmonary bypass (38%) and heart failure following cardiopulmonary bypass weaning (48%). The doubly robust analysis after inverse probability treatment weighting by propensity score demonstrated that central VA-ECMO was associated with greater hospital mortality (odds ratio 1.54; 95% confidence interval, 1.09-2.18), reoperation for bleeding/tamponade (odds ratio, 1.96; 95% confidence interval, 1.37-2.81), and transfusion of more than 9 RBC units (odds ratio, 2.42; 95% confidence interval, 1.59-3.67). The systematic review provided a total of 2491 individuals with postcardiotomy shock treated with VA-ECMO. Pooled prevalence of in-hospital/30-day mortality in overall patient population was 66.6% (95% confidence interval, 64.7-68.4%), and pooled unadjusted risk ratio analysis confirmed that patients undergoing peripheral VA-ECMO had a lower in-hospital/30-day mortality than patients undergoing central cannulation (risk ratio, 0.92; 95% confidence interval, 0.87-0.98). Adjustments for important confounders did not alter our results.ConclusionsIn patients with postcardiotomy shock treated with VA-ECMO, central cannulation was associated with greater in-hospital mortality than peripheral cannulation.</p

    The European Registry for Patients with Mechanical Circulatory Support of the European Association for Cardio-Thoracic Surgery:third report

    Get PDF
    OBJECTIVES: In the third report of the European Registry for Patients with Mechanical Circulatory Support of the European Association for Cardio-Thoracic Surgery, outcomes of patients receiving mechanical circulatory support are reviewed in relation to implant era. METHODS: Procedures in adult patients (January 2011-June 2020) were included. Patients from centres with 3 months). Risk factors for death were explored using univariable Cox regression with a stepwise time-varying hazard ratio (3 months). RESULTS: In total, 4834 procedures in 4486 individual patients (72 hospitals) were included, with a median follow-up of 1.1 (interquartile range: 0.3-2.6) years. The annual number of implants (range: 346-600) did not significantly change (P = 0.41). Both Interagency Registry for Mechanically Assisted Circulatory Support class (classes 4-7: 23, 25 and 33%; P 3 months: 0.45). Bilirubin and creatinine levels were significant risk factors in the early phase but not in the late phase after the implant. CONCLUSIONS: In its 10 years of existence, EUROMACS has become a point of reference enabling benchmarking and outcome monitoring. Patient characteristics and outcomes changed between implant eras. In addition, both occurrence of outcomes and risk factor weights are time dependent
    corecore