7 research outputs found

    CT Perfusion as a Predictor of the Final Infarct Volume in Patients with Tandem Occlusion

    Get PDF
    Background: CT perfusion (CTP) is used in patients with anterior circulation acute ischemic stroke (AIS) for predicting the final infarct volume (FIV). Tandem occlusion (TO), involving both intracranial large vessels and the ipsilateral cervical internal carotid artery could generate hemodynamic changes altering perfusion parameters. Our aim is to evaluate the accuracy of CTP in the prediction of the FIV in TOs. Methods: consecutive patients with AIS due to middle cerebral artery occlusion, referred to a tertiary stroke center between March 2019 and January 2021, with an automated CTP and successful recanalization (mTICI = 2b - 3) after endovascular treatment were retrospectively included in the tandem group (TG) or in the control group (CG). Patients with parenchymal hematoma type 2, according to ECASS II classification of hemorrhagic transformations, were excluded in a secondary analysis. Demographic, clinical, radiological, time intervals, safety, and outcome measures were collected. Results: among 319 patients analyzed, a comparison between the TG (N = 22) and CG (n = 37) revealed similar cerebral blood flow (CBF) > 30% (29.50 +/- 32.33 vs. 15.76 +/- 20.93 p = 0.18) and FIV (54.67 +/- 65.73 vs. 55.14 +/- 64.64 p = 0.875). Predicted ischemic core (PIC) and FIV correlated in both TG (tau = 0.761, p < 0.001) and CG (tau = 0.315, p = 0.029). The Bland-Altmann plot showed agreement between PIC and FIV for both groups, mainly in the secondary analysis. Conclusion: automated CTP could represent a good predictor of FIV in patients with AIS due to TO

    How a decade of aneurysms embolization with the Woven EndoBridge has changed our understanding and practices?

    No full text
    Background: Safety and efficacy of the WEB (Woven EndoBridge) device have been extensively evaluated in several good clinical practice studies. Nonetheless, the WEB had several structural evolutions overtime up to the fifth generation WEB device (WEB17). Here, we tried to understand how this may have modified our practices and enlarged our indications for its use. Methods: We retrospectively analyzed data from all patients with aneurysms treated (or intended to be treated) with a WEB at our institution between July 2012 and February 2022. The time frame was split in two periods: before and after the arrival of the WEB17 in our center (February 2017). Results: 252 patients with 276 wide-necked aneurysms were included; 78 aneurysms (28.2%) were ruptured. Successful embolization with a WEB device was achieved in 263/276 aneurysms (95.3%). With the availability of WEB17, treated aneurysms were significantly smaller (8.2 mm versus 5.9 mm, p<0.001) and off-label location significantly increased (4.4% versus 17.3%, p = 0.02) with an increase of sidewall aneurysm (4.4% versus 11.6%, p = 0.06). Also, WEB were more significantly oversized (1.05 versus 1.11, p<0.01). Adequate and complete occlusion rates increased constantly during the two periods (54.8% versus 67.5%, p = 0.08 and 74.2% versus 83.7%, p = 0.10, respectively). The proportion of ruptured aneurysms slightly increased between the two periods (24.6% versus 29.5%, p = 0.44). Conclusions: Over the first decade of its availability, the WEB device usage shifted towards smaller aneurysms and broader indications, including ruptured aneurysms. The oversizing strategy also became the standard of practice for WEB deployment in our institution

    Simplified pressure cooker technique for the treatment of brain AVMs, dAVFs and facial vascular malformations

    No full text
    In 2014, Chapot et al. introduced the pressure cooker technique (PCT), conceived to control undesired reflux of the embolic agent during the treatment of brain arterio-venous malformations (bAVMs). Since then, this technique increased in popularity and it has been extensively used. We present five consecutive cases in which the original PCT was simplified using nylon coils instead of platinum coils and acrylic glue, hence the name of 'Simplified Pressure Cooker Technique' (sPCT). The aim was to obtain a safer, precise and faster creation of the plug to control cohesive embolic agent reflux during the treatment of brain and facial vascular malformations

    Clinical and imaging findings in enteropathic spondyloarthritis with special emphasize in diagnostic delay: a cross-sectional study

    No full text
    Background: Enteropathic spondyloarthritides (eSpAs) are chronic inflammatory joint diseases associated with inflammatory bowel disease (IBD). Limited data are available on the prevalence since arthritis in IBD patients may be underestimated because medications may hide disease activity with a possible diagnostic delay. Objectives: We aimed to evaluate diagnostic delay in eSpA and explore associated demographic, clinical, and radiographic characteristics. Design: Single-centre cross-sectional study conducted on consecutive out-patients referred to the combined Gi-Rhe clinic (November 2018–October 2019). Methods: We analysed eSpA patients for diagnostic delay, disease activity, inflammatory markers, conventional radiography (CR) and magnetic resonance images (MRI) of sacroiliac joints/spine. Results: A total of 190 eSpA patients [118 peripheral SpA, 72 axial (Ax) SpA including 44 non-radiographic (nr)-axSpA] were enrolled. axSpA patients had a higher prevalence of men sex, HLA-B27 positivity, uveitis and pancolitis compared with peripheral eSpA. Median diagnostic delay in eSpA was 48 months (IQR 6–77) with no difference between axial and peripheral patients. Radiographic-axial SpA (r-axSpA) patients displayed a higher diagnostic delay compared with nr-axSpA (median/IQR 36/17–129 versus 31/10–57 months, p  = 0.03) and were older, with longer disease duration, low education status and high rate of employment than patients with nr-axSpA. r-axSpA patients with sclerosis, syndesmophytes and bridge at CR had higher diagnostic delay than those without lesions. Men showed higher prevalence of spine damage lesions than women as sclerosis, squaring, syndesmophytes and bridges. Longer disease duration was detected in patients with radiographic damage as bridge and sacroiliitis grade 3. On MRI, sacroiliac bone oedema was associated with reduced diagnostic delay, whereas bone erosions were associated with higher diagnostic delay compared with that in patients without these lesions. Patients with psoriasis displayed a higher diagnostic delay compared to those without skin involvement. Conclusion: Diagnostic delay was higher in r-axSpA compared with nr-axSpA despite the same treatment. Demographic, clinical features and radiological lesions were associated with diagnostic delay

    Determinants of cerebral aneurysm occlusion after embolization with the WEB device: A single-institution series of 215 cases with angiographic follow-up

    No full text
    International audienceBackground Woven EndoBridge (WEB) devices are becoming a reliable option for the treatment of wide-neck bifurcation aneurysms, but clear predictive factors are still missing to understand the one in five aneurysm remnant rate. Objective To evaluate occlusion outcomes after WEB treatment to identify potential determinants of aneurysm occlusion. Methods A single-center database with consecutive aneurysms treated with WEB between July 2012 and October 2021 was reviewed for potential determinants of aneurysm adequate occlusion (defined as a BicĂȘtre Occlusion Scale Score (BOSS) of 0, 0', 1 or 2), through univariate and multivariable analysis. Patients without angiographic follow-up were excluded. Results 215 of 247 individual aneurysms were included in the final analysis, of which 59 (27%) were ruptured. Mean age of patients was 56 years (range 23-90 years) and 65% were female. Mean angiographic follow-up was at 18 months (range 3-97 months). Adequate and complete occlusion were achieved in 171/215 (79.5%) and 135/215 (62.8%) of cases, respectively. Aneurysm irregular shape (aOR=0.42, 95% CI 0.20 to 0.88; p=0.02), aneurysm height (aOR=0.79, 95% CI 0.66 to 0.94; p<0.01), and WEB shape modification (aOR=0.98, 95% CI 0.97 to 1.00; p=0.02) were all independent predictors of aneurysm recurrence, whereas the WEB oversizing ratio (WEB width/aneurysm mean width) (aOR=16.4, 95% CI 1.4 to 266.7; p=0.04) was an independent predictor of adequate occlusion. Conclusion In this study we demonstrated that a width oversizing strategy of the WEB device was an independent predictor of aneurysm angiographic occlusion. Conversely, aneurysm height, irregular aneurysm, and WEB shape modification were all independent determinants of angiographic aneurysm remnant. These results may help to select aneurysms suitable for the WEB device and WEB sizing

    Neurophysiological monitoring during endovascular treatment of brain arteriovenous malformations: A meta-analysis

    No full text
    Background: Treatment of brain arteriovenous malformations (b-AVM) carries a risk of iatrogenic injury to eloquent brain regions. Intraoperative neuro-monitoring (IONM) has increasingly been used to monitor spontaneous or evoked neural activity during neurosurgery, but its use is not as well characterized in the endovascular treatment (EVT) of b-AVMs. We aimed to provide a systematic review and meta-analysis of studies reporting any neurological deficit after b-AVM embolization with IONM, with or without provocative test (PT), and no-IONM. Methods: This systematic review followed the PRISMA guidelines. Medline, EMBASE, and Scopus were searched from conception until March 1, 2022 for studies evaluating EVT with IONM and PT. Primary outcome was the rate of postoperative neurological deficits in EVT with IONM versus no-IONM, while secondary outcome was the subanalysis of IONM with or without PT. Meta-analysis was performed using the Mantel-Haenszel method and random effects modeling. Results: Six studies reached synthesis. Out of a total of 192 EVT, 14 events occurred. Results demonstrated a nonsignificant trend favoring IONM compared to no-IONM to prevent neurological deficits (OR 0.09, 95% CI 0-4.68). Among the EVT with IONM, PT was done in 411 branches with 10 events (0.2%) despite a negative PT. There was a nonsignificant trend favoring IONM plus PT compared to IONM without PT (OR 0.16, 95% CI 0.02-1.07). Conclusions: Our study suggests that b-AVM EVT with IONM plus PT might reduce rates of postprocedural neurological deficits compared with EVT without IONM. Further studies are needed to confirm these results
    corecore