7 research outputs found

    Capacity of dental equipment to interfere with cardiac implantable electrical devices

    Full text link
    Patients with cardiac implantable electrical devices should take precautions when exposed to electromagnetic fields. Possible interference as a result of proximity to electromagnets or electricity flow from electronic tools employed in clinical odontology remains controversial. The objective of this study was to examine in vitro the capacity of dental equipment to provoke electromagnetic interference in pacemakers and implantable cardioverter defibrillators. Six electronic dental instruments were tested on three implantable cardioverter defibrillators and three pacemakers from different manufacturers. A simulator model, submerged in physiological saline, with elements that reproduced life-size anatomic structures was used. The instruments were analyzed at differing distances and for different time periods of application. The dental instruments studied displayed significant differences in their capacity to trigger electromagnetic interference. Significant differences in the quantity of registered interference were observed with respect to the variables manufacturer, type of cardiac implant, and application distance but not with the variable time of application. The electronic dental equipment tested at a clinical application distance (20 cm) provoked only slight interference in the pacemakers and implantable cardioverter defibrillators employed, irrespective of manufacturer

    Trends in the use of electrical cardioversion for atrial fibrillation: influence of major trials and guidelines on clinical practice

    Full text link
    Background: The purpose of the present study was to assess the trends in the use of ECV following published studies that had compared rhythm and rate control strategies on atrial fibrillation (AF), and the recommendations included in the current clinical practice guidelines. Methods: The REVERCAT is a population-based assessment of the use of electrical cardioversion (ECV) in treating persistent AF in Catalonia (Spain). The initial survey was conducted in 2003 and the follow-up in 2010. Results: We observed a decrease of 9% in the absolute numbers of ECV performed (436 in 2003 vs. 397 in 2010). This is equivalent to 27% when considering population increases over this period. The patients treated with ECV in 2010 were younger, had a lower prevalence of previous embolism, a higher prevalence of diabetes, and increased body weight. Underlying heart disease factors indicated, in 2010, a higher proportion of NYHA >= II and left ventricular ejection fraction <30%. We observed a reduction in the number of ECV performed in 16 of the 27 (67%) participating hospitals. However, there was an increase of 14% in the number of procedures performed in tertiary hospitals, and was related to the increasing use of ECV as a bridge to AF ablation. Considering the initial number of patients treated with ECV, the rate of sinus rhythm at 3 months was almost unchanged (58% in 2003 vs. 57% in 2010; p = 0.9) despite the greater use of biphasic energy in 2010 and a similar prescription of anti-arrhythmic drugs. Conclusions: Although we observed a decrease in the number of ECVs performed over the 7 year period between the two studies, this technique remains a common option for treating patients with persistent AF. The change in the characteristics of candidate patients did not translate into better outcomes

    Aortic perforation by active-fixation atrial pacing lead: an unusual but serious complication

    Get PDF
    Perforation of a cardiac chamber is an infrequent but serious sequela of pacemaker lead implantation. An even rarer event is the perforation of the aorta by a protruding right atrial wire. We present here the first case in the medical literature of aortic perforation as a sequela to the implantation of a cardiac resynchronization therapy defibrillator. The patient was a 54-year-old man with idiopathic dilated cardiomyopathy who underwent the implantation of a defibrillator, with no apparent sequelae. Six hours after the procedure, he experienced cardiac tamponade and required urgent open-chest surgery. The pericardial effusion was found to be caused by mechanical friction of a protruding right atrial wire on the aortic root. The aortic root and the atrial wall were both repaired with Prolene suture, which achieved complete control of the bleeding. There was no need to reposition the atrial wire. The patient had a good postoperative recovery

    Capacity of dental equipment to interfere with cardiac implantable electrical devices

    No full text
    Patients with cardiac implantable electrical devices should take precautions when exposed to electromagnetic fields. Possible interference as a result of proximity to electromagnets or electricity flow from electronic tools employed in clinical odontology remains controversial. The objective of this study was to examine in vitro the capacity of dental equipment to provoke electromagnetic interference in pacemakers and implantable cardioverter defibrillators. Six electronic dental instruments were tested on three implantable cardioverter defibrillators and three pacemakers from different manufacturers. A simulator model, submerged in physiological saline, with elements that reproduced life-size anatomic structures was used. The instruments were analyzed at differing distances and for different time periods of application. The dental instruments studied displayed significant differences in their capacity to trigger electromagnetic interference. Significant differences in the quantity of registered interference were observed with respect to the variables manufacturer, type of cardiac implant, and application distance but not with the variable time of application. The electronic dental equipment tested at a clinical application distance (20 cm) provoked only slight interference in the pacemakers and implantable cardioverter defibrillators employed, irrespective of manufacturer

    Trends in the use of electrical cardioversion for atrial fibrillation: influence of major trials and guidelines on clinical practice

    No full text
    Background: The purpose of the present study was to assess the trends in the use of ECV following published studies that had compared rhythm and rate control strategies on atrial fibrillation (AF), and the recommendations included in the current clinical practice guidelines. Methods: The REVERCAT is a population-based assessment of the use of electrical cardioversion (ECV) in treating persistent AF in Catalonia (Spain). The initial survey was conducted in 2003 and the follow-up in 2010. Results: We observed a decrease of 9% in the absolute numbers of ECV performed (436 in 2003 vs. 397 in 2010). This is equivalent to 27% when considering population increases over this period. The patients treated with ECV in 2010 were younger, had a lower prevalence of previous embolism, a higher prevalence of diabetes, and increased body weight. Underlying heart disease factors indicated, in 2010, a higher proportion of NYHA >= II and left ventricular ejection fraction <30%. We observed a reduction in the number of ECV performed in 16 of the 27 (67%) participating hospitals. However, there was an increase of 14% in the number of procedures performed in tertiary hospitals, and was related to the increasing use of ECV as a bridge to AF ablation. Considering the initial number of patients treated with ECV, the rate of sinus rhythm at 3 months was almost unchanged (58% in 2003 vs. 57% in 2010; p = 0.9) despite the greater use of biphasic energy in 2010 and a similar prescription of anti-arrhythmic drugs. Conclusions: Although we observed a decrease in the number of ECVs performed over the 7 year period between the two studies, this technique remains a common option for treating patients with persistent AF. The change in the characteristics of candidate patients did not translate into better outcomes

    Aortic perforation by active-fixation atrial pacing lead: an unusual but serious complication

    No full text
    Perforation of a cardiac chamber is an infrequent but serious sequela of pacemaker lead implantation. An even rarer event is the perforation of the aorta by a protruding right atrial wire. We present here the first case in the medical literature of aortic perforation as a sequela to the implantation of a cardiac resynchronization therapy defibrillator. The patient was a 54-year-old man with idiopathic dilated cardiomyopathy who underwent the implantation of a defibrillator, with no apparent sequelae. Six hours after the procedure, he experienced cardiac tamponade and required urgent open-chest surgery. The pericardial effusion was found to be caused by mechanical friction of a protruding right atrial wire on the aortic root. The aortic root and the atrial wall were both repaired with Prolene suture, which achieved complete control of the bleeding. There was no need to reposition the atrial wire. The patient had a good postoperative recovery

    Homenatge a Sebastià Serrano

    No full text
    Coordinadors: M. Antònia Martí i Mariona TauléAquest volum és un recull d’articles publicats en homenatge a Sebastià Serrano, catedràtic de lingüística general i teoria de la comunicació a la Universitat de Barcelona, amb motiu de la seva jubilació. S’hi apleguen treballs de temàtica molt diversa, de la morfologia del català, el castellà o el basc, a la semàntica, de la poesia galaicoportuguesa a la literatura russa o a l’òpera wagneriana. Són contribucions escrites per companys de professió des de l’admiració i el reconeixement cap a la figura de Serrano, lingüista i matemàtic, pensador polièdric i gran comunicador. En aquesta àmplia variació de temes i de punts de vista es reflecteix el mestratge que ha exercit en els seus col·legues: una visió interdisciplinària i transversal no només de la lingüística, sinó del coneixement humà