14 research outputs found

    Technology Acceptance of Navid Learning Management System in the Iranian Medical English Courses under the COVID-19 Pandemic

    Get PDF
    This mixed-method study endeavored to solicit the perspectives of Iranian collegiate students passing the obligatory course of medical English through Navid Learning Management System and its acceptance during COVID-19 pandemic. Utilizing Technology Acceptance Model, this study also sought to examine the possible effect gender, academic degree, instructional mode, and e-learning duration in LMS may have on the participants' attitudes. An online survey was employed to gather data from 78 Iranian students. Semi-structured interviews with ten participants were conducted as well to shed more light on the quantitative data regarding main advantages and disadvantages of medical English learning through Navid. The data were analyzed through descriptive and inferential statistics along with inductive thematic analysis, respectively. Findings revealed that Iranian collegiate medical students viewed Navid as a comprehensive e-learning platform to be favorable in terms of its system/service quality, student/educational service quality, and perceived satisfaction, but its perceived satisfaction was not aligned with their needs. Moreover, neither the individual variables, (viz., age and academic degree), nor the instructional variables (viz., instructional mode and e-learning duration) were predictors of the discrepancies among the participants in their perspectives and acceptance of Navid. Learning ubiquitously and lacking face-to-face communication were the main advantage and disadvantage of learning medical English through Navid, respectively. Results revealed that although under the Covid-19 pandemic the acceptance of Navid and students' satisfaction with its use might not be related to the individual and instructional variables in the medical English courses, it might not be the case in others

    Global, regional, and national burden of rheumatoid arthritis, 1990–2020, and projections to 2050: a systematic analysis of the Global Burden of Disease Study 2021

    Get PDF
    Background Rheumatoid arthritis is a chronic autoimmune inflammatory disease associated with disability and premature death. Up-to-date estimates of the burden of rheumatoid arthritis are required for health-care planning, resource allocation, and prevention. As part of the Global Burden of Diseases, Injuries, and Risk Factors Study (GBD) 2021, we provide updated estimates of the prevalence of rheumatoid arthritis and its associated deaths and disability-adjusted life-years (DALYs) by age, sex, year, and location, with forecasted prevalence to 2050. Methods Rheumatoid arthritis prevalence was estimated in 204 countries and territories from 1990 to 2020 using Bayesian meta-regression models and data from population-based studies and medical claims data (98 prevalence and 25 incidence studies). Mortality was estimated from vital registration data with the Cause of Death Ensemble model (CODEm). Years of life lost (YLL) were calculated with use of standard GBD lifetables, and years lived with disability (YLDs) were estimated from prevalence, a meta-analysed distribution of rheumatoid arthritis severity, and disability weights. DALYs were calculated by summing YLLs and YLDs. Smoking was the only risk factor analysed. Rheumatoid arthritis prevalence was forecast to 2050 by logistic regression with Socio-Demographic Index as a predictor, then multiplying by projected population estimates. Findings In 2020, an estimated 17·6 million (95% uncertainty interval 15·8–20·3) people had rheumatoid arthritis worldwide. The age-standardised global prevalence rate was 208·8 cases (186·8–241·1) per 100 000 population, representing a 14·1% (12·7–15·4) increase since 1990. Prevalence was higher in females (age-standardised female-to-male prevalence ratio 2·45 [2·40–2·47]). The age-standardised death rate was 0·47 (0·41–0·54) per 100 000 population (38 300 global deaths [33 500–44 000]), a 23·8% (17·5–29·3) decrease from 1990 to 2020. The 2020 DALY count was 3 060 000 (2 320 000–3 860 000), with an age-standardised DALY rate of 36·4 (27·6–45·9) per 100 000 population. YLDs accounted for 76·4% (68·3–81·0) of DALYs. Smoking risk attribution for rheumatoid arthritis DALYs was 7·1% (3·6–10·3). We forecast that 31·7 million (25·8–39·0) individuals will be living with rheumatoid arthritis worldwide by 2050. Interpretation Rheumatoid arthritis mortality has decreased globally over the past three decades. Global age-standardised prevalence rate and YLDs have increased over the same period, and the number of cases is projected to continue to increase to the year 2050. Improved access to early diagnosis and treatment of rheumatoid arthritis globally is required to reduce the future burden of the disease.publishedVersio

    INVESTIGATING EFL LEARNERS’ PERSPECTIVES ON VOCABULARY LEARNING EXPERIENCES THROUGH SMARTPHONE APPLICATIONS

    No full text
    This study investigated EFL learners’ perspectives about their vocabulary learning experiences via a smartphone application. An online demographic questionnaire was used for recruiting 50 EFL learners from a language teaching channel in Telegram messenger required to use a smartphone application called Vocabulary Flashcards 2016 for a month. After finishing the sampling procedure, the participants were asked to take part in Dialang online diagnostic test to specify their vocabulary level proficiency based on CEFR (Common European Framework of Reference). The quantitative and qualitative data were collected utilizing evaluation questionnaires and semi-structured interviews respectively. The evaluation questionnaire adapted from Chapelle’s (2001) evaluation criterion was used to evaluate the application from the users’ perspectives. This study investigated the effects of learners’ proficiency level and gender differences on using the application, and their perspectives on the negative and positive aspects of the application were also uncovered. The findings showed that the users held positive attitudes towards the application because it influenced their learning positively and provided them with both form and meaning-focused instruction, but they were dissatisfied with the app’s levels and authenticity. Results of independent t-test and ANOVA respectively showed that gender and vocabulary proficiency level did not make significant difference on participants’ app usage patterns. The findings of this study highlighted the users’ localized needs which could be used as guidelines for customized vocabulary apps’ development purposes. The study’s implications for learners, teachers, and app developers are discussed in detail

    The relationship between pain score and change in physiological indices of premature neonates under ventilation

    No full text
    Background & Aim: Tracheal suctioning is one of the ways to clean and open the airway in infants admitted to the neonatal intensive care unit that can be with many negative consequences such as pain, decrease in arterial oxygen saturation, pneumonia, heart rhythm disorder, change In the rhythm and number of respiration and sepsis. Materials & Methods: This is a descriptive correlational study with IR.UMSHA.REC.1395.424 ethical code, was performed on 120 preterm infants in neonatal intensive care unit of Besat and Fatemieh Hospitals of Hamedan. Firstly, before suctioning the patient, the heart rate index of the newborn that needed to be suctioned was registered by the researcher in three shifts based on the findings of the direct monitoring of the infant. The heart rate index was re-recorded during suction. Data were analyzed using descriptive and regression tests. Results: Infants with a catheter of 6 to 9 french were suctioned at 80 to 85 suction pressure. In 26% of cases, the suctioning standards for the duration of suction, standard pressure and proper size of the catheter were not observed. There was a significant difference between the change in heart rate index and pain score (P=0.001). Conclusion: Failure to observe suction standards in premature infants can lead to changes in heart rate index and increase their basic needs, which can impair the recovery process of preterm infants

    3D Printing of Alginate/Chitosan-Based Scaffold Empowered by Tyrosol-Loaded Niosome for Wound Healing Applications: In Vitro and In Vivo Performances

    No full text
    This study introduces a tyrosol-loaded niosome integrated into a chitosan–alginate scaffold (Nio-Tyro@CS-AL), employing advanced electrospinning and 3D printing techniques for wound healing applications. The niosomes, measuring 185.40 ± 6.40 nm with a polydispersity index of 0.168 ± 0.012, encapsulated tyrosol with an efficiency of 77.54 ± 1.25%. The scaffold’s microsized porous structure (600–900 ÎŒm) enhances water absorption, promoting cell adhesion, migration, and proliferation. Mechanical property assessments revealed the scaffold’s enhanced resilience, with niosomes increasing the compressive strength, modulus, and strain to failure, indicative of its suitability for wound healing. Controlled tyrosol release was demonstrated in vitro, essential for therapeutic efficacy. The scaffold exhibited significant antibacterial activity against Pseudomonas aeruginosa and Staphylococcus aureus, with substantial biofilm inhibition and downregulation of bacterial genes (ndvb and icab). A wound healing assay highlighted a notable increase in MMP-2 and MMP-9 mRNA expression and the wound closure area (69.35 ± 2.21%) in HFF cells treated with Nio-Tyro@CS-AL. In vivo studies in mice confirmed the scaffold’s biocompatibility, showing no significant inflammatory response, hypertrophic scarring, or foreign body reaction. Histological evaluations revealed increased fibroblast and macrophage activity, enhanced re-epithelialization, and angiogenesis in wounds treated with Nio-Tyro@CS-AL, indicating effective tissue integration and repair. Overall, the Nio-Tyro@CS-AL scaffold presents a significant advancement in wound-healing materials, combining antibacterial properties with enhanced tissue regeneration, and holds promising potential for clinical applications in wound management

    Characterization of a flexible a-Si:H detector for in vivo dosimetry in therapeutic x-ray beams

    No full text
    Background: The increasing use of complex and high dose-rate treatments in radiation therapy necessitates advanced detectors to provide accurate dosimetry. Rather than relying on pre-treatment quality assurance (QA) measurements alone, many countries are now mandating the use of in vivo dosimetry, whereby a dosimeter is placed on the surface of the patient during treatment. Ideally, in vivo detectors should be flexible to conform to a patient\u27s irregular surfaces. Purpose: This study aims to characterize a novel hydrogenated amorphous silicon (a-Si:H) radiation detector for the dosimetry of therapeutic x-ray beams. The detectors are flexible as they are fabricated directly on a flexible polyimide (Kapton) substrate. Methods: The potential of this technology for application as a real-time flexible detector is investigated through a combined dosimetric and flexibility study. Measurements of fundamental dosimetric quantities were obtained including output factor (OF), dose rate dependence (DPP), energy dependence, percentage depth dose (PDD), and angular dependence. The response of the a-Si:H detectors investigated in this study are benchmarked directly against commercially available ionization chambers and solid-state diodes currently employed for QA practices. Results: The a-Si:H detectors exhibit remarkable dose linearities in the direct detection of kV and MV therapeutic x-rays, with calibrated sensitivities ranging from (0.580 ± 0.002) pC/cGy to (19.36 ± 0.10) pC/cGy as a function of detector thickness, area, and applied bias. Regarding dosimetry, the a-Si:H detectors accurately obtained OF measurements that parallel commercially available detector solutions. The PDD response closely matched the expected profile as predicted via Geant4 simulations, a PTW Farmer ionization chamber and a PTW ROOS chamber. The most significant variation in the PDD performance was 5.67%, observed at a depth of 3 mm for detectors operated unbiased. With an external bias, the discrepancy in PDD response from reference data was confined to ± 2.92% for all depths (surface to 250 mm) in water-equivalent plastic. Very little angular dependence is displayed between irradiations at angles of 0° and 180°, with the most significant variation being a 7.71% decrease in collected charge at a 110° relative angle of incidence. Energy dependence and dose per pulse dependence are also reported, with results in agreement with the literature. Most notably, the flexibility of a-Si:H detectors was quantified for sample bending up to a radius of curvature of 7.98 mm, where the recorded photosensitivity degraded by (−4.9 ± 0.6)% of the initial device response when flat. It is essential to mention that this small bending radius is unlikely during in vivo patient dosimetry. In a more realistic scenario, with a bending radius of 15–20 mm, the variation in detector response remained within ± 4%. After substantial bending, the detector\u27s photosensitivity when returned to a flat condition was (99.1 ± 0.5)% of the original response. Conclusions: This work successfully characterizes a flexible detector based on thin-film a-Si:H deposited on a Kapton substrate for applications in therapeutic x-ray dosimetry. The detectors exhibit dosimetric performances that parallel commercially available dosimeters, while also demonstrating excellent flexibility results

    Dosimetry of microbeam radiotherapy by flexible hydrogenated amorphous silicon detectors

    No full text
    Objective. Detectors that can provide accurate dosimetry for microbeam radiation therapy (MRT) must possess intrinsic radiation hardness, a high dynamic range, and a micron-scale spatial resolution. In this work we characterize hydrogenated amorphous silicon detectors for MRT dosimetry, presenting a novel combination of flexible, ultra-thin and radiation-hard features. Approach. Two detectors are explored: an n-type/intrinsic/p-type planar diode (NIP) and an NIP with an additional charge selective layer (NIP + CSC). Results. The sensitivity of the NIP + CSC detector was greater than the NIP detector for all measurement conditions. At 1 V and 0 kGy under the 3T Cu-Cu synchrotron broadbeam, the NIP + CSC detector sensitivity of (7.76 ± 0.01) pC cGy−1 outperformed the NIP detector sensitivity of (3.55 ± 0.23) pC cGy−1 by 219%. The energy dependence of both detectors matches closely to the attenuation coefficient ratio of silicon against water. Radiation damage measurements of both detectors out to 40 kGy revealed a higher radiation tolerance in the NIP detector compared to the NIP + CSC (17.2% and 33.5% degradations, respectively). Percentage depth dose profiles matched the PTW microDiamond detector’s performance to within ±6% for all beam filtrations except in 3T Al-Al due to energy dependence. The 3T Cu-Cu microbeam field profile was reconstructed and returned microbeam width and peak-to-peak values of (51 ± 1) ÎŒm and (405 ± 5) ÎŒm, respectively. The peak-to-valley dose ratio was measured as a function of depth and agrees within error to the values obtained with the PTW microDiamond. X-ray beam induced charge mapping of the detector revealed minimal dose perturbations from extra-cameral materials. Significance. The detectors are comparable to commercially available dosimeters for quality assurance in MRT. With added benefits of being micron-sized and possessing a flexible water-equivalent substrate, these detectors are attractive candidates for quality assurance, in-vivo dosimetry and in-line beam monitoring for MRT and FLASH therapy

    Characterization of a flexible a‐Si:H detector for in vivo dosimetry in therapeutic x‐ray beams

    No full text
    Background: The increasing use of complex and high dose-rate treatments in radiation therapy necessitates advanced detectors to provide accurate dosimetry. Rather than relying on pre-treatment quality assurance (QA) measurements alone, many countries are now mandating the use of in vivo dosimetry, whereby a dosimeter is placed on the surface of the patient during treatment. Ideally, in vivo detectors should be flexible to conform to a patient's irregular surfaces. Purpose: This study aims to characterize a novel hydrogenated amorphous silicon (a-Si:H) radiation detector for the dosimetry of therapeutic x-ray beams. The detectors are flexible as they are fabricated directly on a flexible polyimide (Kapton) substrate. Methods: The potential of this technology for application as a real-time flexible detector is investigated through a combined dosimetric and flexibility study. Measurements of fundamental dosimetric quantities were obtained including output factor (OF), dose rate dependence (DPP), energy dependence, percentage depth dose (PDD), and angular dependence. The response of the a-Si:H detectors investigated in this study are benchmarked directly against commercially available ionization chambers and solid-state diodes currently employed for QA practices. Results: The a-Si:H detectors exhibit remarkable dose linearities in the direct detection of kV and MV therapeutic x-rays, with calibrated sensitivities ranging from (0.580 ± 0.002) pC/cGy to (19.36 ± 0.10) pC/cGy as a function of detector thickness, area, and applied bias. Regarding dosimetry, the a-Si:H detectors accurately obtained OF measurements that parallel commercially available detector solutions. The PDD response closely matched the expected profile as predicted via Geant4 simulations, a PTW Farmer ionization chamber and a PTW ROOS chamber. The most significant variation in the PDD performance was 5.67%, observed at a depth of 3 mm for detectors operated unbiased. With an external bias, the discrepancy in PDD response from reference data was confined to ± 2.92% for all depths (surface to 250 mm) in water-equivalent plastic. Very little angular dependence is displayed between irradiations at angles of 0° and 180°, with the most significant variation being a 7.71% decrease in collected charge at a 110° relative angle of incidence. Energy dependence and dose per pulse dependence are also reported, with results in agreement with the literature. Most notably, the flexibility of a-Si:H detectors was quantified for sample bending up to a radius of curvature of 7.98 mm, where the recorded photosensitivity degraded by (-4.9 ± 0.6)% of the initial device response when flat. It is essential to mention that this small bending radius is unlikely during in vivo patient dosimetry. In a more realistic scenario, with a bending radius of 15-20 mm, the variation in detector response remained within ± 4%. After substantial bending, the detector's photosensitivity when returned to a flat condition was (99.1 ± 0.5)% of the original response. Conclusions: This work successfully characterizes a flexible detector based on thin-film a-Si:H deposited on a Kapton substrate for applications in therapeutic x-ray dosimetry. The detectors exhibit dosimetric performances that parallel commercially available dosimeters, while also demonstrating excellent flexibility results

    Dosimetry of microbeam radiotherapy by flexible hydrogenated amorphous silicon detectors

    No full text
    : Objective.Detectors that can provide accurate dosimetry for microbeam radiation therapy (MRT) must possess intrinsic radiation hardness, a high dynamic range, and a micron-scale spatial resolution. In this work we characterize hydrogenated amorphous silicon detectors for MRT dosimetry, presenting a novel combination of flexible, ultra-thin and radiation-hard features.Approach.Two detectors are explored: an n-type/intrinsic/p-type planar diode (NIP) and an NIP with an additional charge selective layer (NIP + CSC).Results.The sensitivity of the NIP + CSC detector was greater than the NIP detector for all measurement conditions. At 1 V and 0 kGy under the 3T Cu-Cu synchrotron broadbeam, the NIP + CSC detector sensitivity of (7.76 ± 0.01) pC cGy-1outperformed the NIP detector sensitivity of (3.55 ± 0.23) pC cGy-1by 219%. The energy dependence of both detectors matches closely to the attenuation coefficient ratio of silicon against water. Radiation damage measurements of both detectors out to 40 kGy revealed a higher radiation tolerance in the NIP detector compared to the NIP + CSC (17.2% and 33.5% degradations, respectively). Percentage depth dose profiles matched the PTW microDiamond detector's performance to within ±6% for all beam filtrations except in 3T Al-Al due to energy dependence. The 3T Cu-Cu microbeam field profile was reconstructed and returned microbeam width and peak-to-peak values of (51 ± 1)Όm and (405 ± 5)Όm, respectively. The peak-to-valley dose ratio was measured as a function of depth and agrees within error to the values obtained with the PTW microDiamond. X-ray beam induced charge mapping of the detector revealed minimal dose perturbations from extra-cameral materials.Significance.The detectors are comparable to commercially available dosimeters for quality assurance in MRT. With added benefits of being micron-sized and possessing a flexible water-equivalent substrate, these detectors are attractive candidates for quality assurance,in-vivodosimetry and in-line beam monitoring for MRT and FLASH therapy
    corecore