1,780 research outputs found

    Rapid soft X-ray fluctuations in solar flares observed with the X-ray polychromator

    Get PDF
    Three flares observed by the Soft X-Ray Polychromator on the Solar Maximum Mission were studied. Flare light curves from the Flat Crystal Spectrometer and Bent Crystal Spectrometer were examined for rapid signal variations. Each flare was characterized by an initial fast (less than 1 min) burst, observed by the Hard X-Ray Burst Spectrometer (HXRBS), followed by softer gradual X-ray emission lasting several minutes. From an autocorrelation function analysis, evidence was found for quasi-periodic fluctuations with rise and decay times of 10 s in the Ca XIX and Fe XXV light curves. These variations were of small amplitude (less than 20%), often coincided with hard X-ray emissions, and were prominent during the onset of the gradual phase after the initial hard X-ray burst. It is speculated that these fluctuations were caused by repeated energy injections in a coronal loop that had already been heated and filled with dense plasma associated with the initial hard X-ray burst

    Deriving Plasma Densities and Elemental Abundances from SERTS Differential Emission Measure Analysis

    Get PDF
    We use high-resolution spectral emission line data obtained by the SERTS instrument during three rocket flights to demonstrate a new approach for constraining electron densities of solar active region plasma.We apply differential emission measure (DEM) forward-fitting techniques to characterize the multithermal solar plasma producing the observed EUV spectra, with constraints on the high-temperature plasma from the Yohkoh Soft X-ray Telescope. In this iterative process, we compare line intensities predicted by an input source distribution to observed line intensities for multiple iron ion species, and search a broad range of densities to optimize chi-square simultaneously for the many available density-sensitive lines. This produces a density weighted by the DEM, which appears to be useful for characterizing the bulk of the emitting plasma over a significant range of temperature. This "DEM-weighted density" technique is complementary to the use of density-sensitive line ratios and less affected by uncertainties in atomic data and ionization fraction for any specific line. Once the DEM shape and the DEM-weighted density have been established from the iron lines, the relative elemental abundances can be determined for other lines in the spectrum. We have also identified spectral lines in the SERTS wavelength range that may be problemati

    CT attenuation analysis of carotid intraplaque hemorrhage

    Get PDF
    Background and Purpose: Intraplaque hemorrhage is considered a leading parameter of carotid plaque vulnerability. Our purpose was to assess the CT characteristics of intraplaque hemorrhage with histopathologic correlation to identify features that allow for confirming or ruling out the intraplaque hemorrhage. MATERIALS AND METHODS: This retrospective study included 91 patients (67 men; median age, 657 years; age range, 41-83 years) who underwent CT angiography and carotid endarterectomy from March 2010 to May 2013. Histopathologic analysis was performed for the tissue characterization and identification of intraplaque hemorrhage. Two observers assessed the plaque's attenuation values by using an ROI (≤1 and ≥2 mm2). Receiver operating characteristic curve, Mann-Whitney, and Wilcoxon analyses were performed. RESULTS: A total of 169 slices were assessed (59 intraplaque hemorrhage, 63 lipid-rich necrotic core, and 47 fibrous); the average values of the intraplaque hemorrhage, lipid-rich necrotic core, and fibrous tissue were 17.475 Hounsfield units (HU) and 18.407 HU, 39.476 HU and 48.048 HU, and 91.66 HU and 93.128 HU, respectively, before and after the administration of contrast medium. The Mann-Whitney test showed a statistically significant difference of HU values both in basal and after the administration of contrast material phase. Receiver operating characteristic analysis showed a statistical association between intraplaque hemorrhage and low HU values, and a threshold of 25 HU demonstrated the presence of intraplaque hemorrhage with a sensitivity and specificity of 93.22% and 92.73%, respectively. The Wilcoxon test showed that the attenuation of the plaque before and after administration of contrast material is different (intraplaque hemorrhage, lipid-rich necrotic core, and fibrous tissue had P values of .006, .0001, and .018, respectively). CONCLUSIONS: The results of this preliminary study suggest that CT can be used to identify the presence of intraplaque hemorrhage according to the attenuation. A threshold of 25 HU in the volume acquired after the administration of contrast medium is associated with an optimal sensitivity and specificity. Special care should be given to the correct identification of the ROI

    A 4.8 hour periodicity in the spectra of Cyg X-3

    Get PDF
    The X-ray spectra from three observations of the X-ray binary Cyg X-3 by the cosmic X-ray spectroscopy experiment on OSO can be represented by power-law continua with strong iron line emission. Comparisons of spectra taken within the same observation at various phases of the 4.8 hour period reveal a relative excess of low energy X-ray emission near zero phase (i.e. the minimum) of the 4.8 hour modulation. In addition, the centroid of the line emission is observed to vary in phase with the 4.8 hour cycle. The possibility of persistent thermal X-ray emission from material surrounding the binary system is introduced in an effort to account for the observed effects

    Artificial Intelligence Applications in Cardiovascular Magnetic Resonance Imaging: Are We on the Path to Avoiding the Administration of Contrast Media?

    Get PDF
    In recent years, cardiovascular imaging examinations have experienced exponential growth due to technological innovation, and this trend is consistent with the most recent chest pain guidelines. Contrast media have a crucial role in cardiovascular magnetic resonance (CMR) imaging, allowing for more precise characterization of different cardiovascular diseases. However, contrast media have contraindications and side effects that limit their clinical application in determinant patients. The application of artificial intelligence (AI)-based techniques to CMR imaging has led to the development of non-contrast models. These AI models utilize non-contrast imaging data, either independently or in combination with clinical and demographic data, as input to generate diagnostic or prognostic algorithms. In this review, we provide an overview of the main concepts pertaining to AI, review the existing literature on non-contrast AI models in CMR, and finally, discuss the strengths and limitations of these AI models and their possible future development

    On Predicting the Solar Cycle using Mean-Field Models

    Full text link
    We discuss the difficulties of predicting the solar cycle using mean-field models. Here we argue that these difficulties arise owing to the significant modulation of the solar activity cycle, and that this modulation arises owing to either stochastic or deterministic processes. We analyse the implications for predictability in both of these situations by considering two separate solar dynamo models. The first model represents a stochastically-perturbed flux transport dynamo. Here even very weak stochastic perturbations can give rise to significant modulation in the activity cycle. This modulation leads to a loss of predictability. In the second model, we neglect stochastic effects and assume that generation of magnetic field in the Sun can be described by a fully deterministic nonlinear mean-field model -- this is a best case scenario for prediction. We designate the output from this deterministic model (with parameters chosen to produce chaotically modulated cycles) as a target timeseries that subsequent deterministic mean-field models are required to predict. Long-term prediction is impossible even if a model that is correct in all details is utilised in the prediction. Furthermore, we show that even short-term prediction is impossible if there is a small discrepancy in the input parameters from the fiducial model. This is the case even if the predicting model has been tuned to reproduce the output of previous cycles. Given the inherent uncertainties in determining the transport coefficients and nonlinear responses for mean-field models, we argue that this makes predicting the solar cycle using the output from such models impossible.Comment: 22 Pages, 5 Figures, Preprint accepted for publication in Ap

    Pulmonary transit time as a marker of diastolic dysfunction in Takotsubo syndrome

    Get PDF
    AIM: To evaluate the pulmonary transit time (PTT) and its derived parameters using cardiac magnetic resonance imaging (CMRI) as markers of diastolic dysfunction in Takotsubo syndrome (TS) and its relationship with transthoracic echocardiography and CMRI parameters. MATERIALS AND METHODS: Twenty-two patients with TS, who exhibited diastolic dysfunction as assessed by transthoracic echocardiography, were enrolled retrospectively and the PTT, pulmonary transit time index (PTTI), and pulmonary blood volume index (PBVI) were evaluated using first-pass CMRI. PTT was calculated as the number of cardiac cycles required for a bolus of contrast agent to move from the right ventricle (RV) to the left ventricle (LV), whereas PTTI represents the PTT interval corrected for the heart rate. Finally, PBVI was calculated as the product of PTTI, and RV stroke volume indexed for body surface area. Normal references of PTT, PTTI, and PBVI were evaluated in a cohort of 20 age- and sex-matched healthy controls. RESULTS: Compared with healthy subjects, TS patients showed significantly higher PTT, PTTI, and PBVI (p=0.0001, p=0.0001, and p=0.002, respectively). Using multivariable logistic regression, PBVI provided the best differentiation between TS and controls (AUC 0.84). PBVI was significantly associated with the index of diastolic dysfunction and left atrial strain parameters. In addition, PBVI demonstrated a significant correlation with global T2 mapping (r=0,520, p=0,019). CONCLUSION: PTT and the derived parameters, as assessed using first-pass CMRI, are potential tools for assessing LV diastolic dysfunction in patients with TS

    Spectral variability of Cyg X-3

    Get PDF
    The 1.7-40 keV spectra of Cyg X-3 obtained about a year apart, using the same rocket payload, show large spectral differences. The two observations suggest that while the luminosity of this source remains roughly the same, its spectrum can vary from a featureless blackbody distribution to a flat spectrum which includes strong iron line emission at approximately 6.7 keV. The flux in the line corresponds to an equivalent continuum width of 1.2 keV

    Collective Excitations of Bose-Einstein Condensates in a Double-Well Potential

    Full text link
    We investigate collective excitations of Bose-Einstein condensates at absolute zero in a double-well trap. We solve the Bogoliubov equations with a double-well trap, and show that the crossover from the dipole mode to the Josephson plasma mode occurs in the lowest energy excitation. It is found that the anomalous tunneling property of low energy excitations is crucial to the crossover.Comment: 14 pages, 6 figure

    Relationship between white matter hyperintensities volume and the circle of Willis configurations in patients with carotid artery pathology

    Get PDF
    Purpose We aimed to assess if there is a difference of distribution and volume of white matter hyperintensities (WMH) in the brain according to the Circle of Willis (CoW) configuration in patients with carotid artery pathology. Material and methods One-hundred consecutive patients (79 males, 21 females; mean age 70 years; age range 46–84 years) that underwent brain MRI before carotid endarterectomy (CEA) were included. FLAIR-WMH lesion volume was performed using a semi-automated segmentation technique and the status of the circle of Willis was assessed by two neuroradiologists in consensus. Results We found a prevalence of 55% of variants in the CoW configuration; 22 cases had one variants (40%); 25 cases had two variants (45.45%) and 8 cases showed 3 variants (14.55%). The configuration that was associated with the biggest WMH volume and number of lesions was the A1 + PcoA + PcoA. The PcoA variants were the most prevalent and there was no statistically significant difference in number of lesions and WMH for each vascular territory assessed and the same results were found for AcoA and A1 variants. Conclusion Results of our study suggest that the more common CoW variants are not associated with the presence of an increased WMH or number of lesions whereas uncommon configurations, in particular when 2 or more segment are missing increase the WMH volume and number of lesions. The WHM volume of the MCA territory seems to be more affected by the CoW configuration
    • …
    corecore