2,039 research outputs found

    Weakening of the stratospheric polar vortex by Arctic sea-ice loss

    Get PDF
    Successive cold winters of severely low temperatures in recent years have had critical social and economic impacts on the mid-latitude continents in the Northern Hemisphere. Although these cold winters are thought to be partly driven by dramatic losses of Arctic sea-ice, the mechanism that links sea-ice loss to cold winters remains a subject of debate. Here, by conducting observational analyses and model experiments, we show how Arctic sea-ice loss and cold winters in extra-polar regions are dynamically connected through the polar stratosphere. We find that decreased sea-ice cover during early winter months (November-December), especially over the Barents-Kara seas, enhances the upward propagation of planetary-scale waves with wavenumbers of 1 and 2, subsequently weakening the stratospheric polar vortex in mid-winter (January-February). The weakened polar vortex preferentially induces a negative phase of Arctic Oscillation at the surface, resulting in low temperatures in mid-latitudes.open11167174Ysciescopu

    Robust Diagnosis Method Based on Parameter Estimation for an Interturn Short-Circuit Fault in Multipole PMSM under High-Speed Operation

    Get PDF
    This paper proposes a diagnosis method for a multipole permanent magnet synchronous motor (PMSM) under an interturn short circuit fault. Previous works in this area have suffered from the uncertainties of the PMSM parameters, which can lead to misdiagnosis. The proposed method estimates the q-axis inductance (L-q) of the faulty PMSM to solve this problem. The proposed method also estimates the faulty phase and the value of G, which serves as an index of the severity of the fault. The q-axis current is used to estimate the faulty phase, the values of G and L-q. For this reason, two open-loop observers and an optimization method based on a particle-swarm are implemented. The q-axis current of a healthy PMSM is estimated by the open-loop observer with the parameters of a healthy PMSM. The L-q estimation significantly compensates for the estimation errors in high-speed operation. The experimental results demonstrate that the proposed method can estimate the faulty phase, G, and L-q besides exhibiting robustness against parameter uncertainties.1165Ysciescopu

    Reduction of Motion Artifacts and Improvement of R Peak Detecting Accuracy Using Adjacent Non-Intrusive ECG Sensors

    Get PDF
    Non-intrusive electrocardiogram (ECG) monitoring has many advantages: easy to measure and apply in daily life. However, motion noise in the measured signal is the major problem of non-intrusive measurement. This paper proposes a method to reduce the noise and to detect the R peaks of ECG in a stable manner in a sitting arrangement using non-intrusive sensors. The method utilizes two capacitive ECG sensors (cECGs) to measure ECG, and another two cECGs located adjacent to the sensors for ECG are added to obtain the information on motion. Then, active noise cancellation technique and the motion information are used to reduce motion noise. To verify the proposed method, ECG was measured indoors and during driving, and the accuracy of the detected R peaks was compared. After applying the method, the sum of sensitivity and positive predictivity increased 8.39% on average and 26.26% maximally in the data. Based on the results, it was confirmed that the motion noise was reduced and that more reliable R peak positions could be obtained by the proposed method. The robustness of the new ECG measurement method will elicit benefits to various health care systems that require noninvasive heart rate or heart rate variability measurements.1145Ysciescopu

    Control of photoluminescence of carbon nanodots via surface functionalization using para-substituted anilines

    Get PDF
    Carbon nanodots (C-dots) are a kind of fluorescent carbon nanomaterials, composed of polyaromatic carbon domains surrounded by amorphous carbon frames, and have attracted a great deal of attention because of their interesting properties. There are still, however, challenges ahead such as blue-biased photoluminescence, spectral broadness, undefined energy gaps and etc. In this report, we chemically modify the surface of C-dots with a series of para-substituted anilines to control their photoluminescence. Our surface functionalization endows our C-dots with new energy levels, exhibiting long-wavelength (up to 650 nm) photoluminescence of very narrow spectral widths. The roles of para-substituted anilines and their substituents in developing such energy levels are thoroughly studied by using transient absorption spectroscopy. We finally demonstrate light-emitting devices exploiting our C-dots as a phosphor, converting UV light to a variety of colors with internal quantum yields of ca. 20%.open116665Ysciescopu

    Charge ordering, ferroelectric, and magnetic domains in LuFe2O4 observed by scanning probe microscopy

    Get PDF
    LuFe2O4 is a multiferroic system which exhibits charge order, ferroelectricity, and ferrimagnetism simultaneously below similar to 230 K. The ferroelectric/charge order domains of LuFe2O4 are imaged with both piezoresponse force microscopy (PFM) and electrostatic force microscopy (EFM), while the magnetic domains are characterized by magnetic force microscopy (MFM). Comparison of PFM and EFM results suggests that the proposed ferroelectricity in LuFe2O4 is not of usual displacive type but of electronic origin. Simultaneous characterization of ferroelectric/charge order and magnetic domains by EFM and MFM, respectively, on the same surface of LuFe2O4 reveals that both domains have irregular patterns of similar shape, but the length scales are quite different. The domain size is approximately 100 nm for the ferroelectric domains, while the magnetic domain size is much larger and gets as large as 1 mu m. We also demonstrate that the origin of the formation of irregular domains in LuFe2O4 is not extrinsic but intrinsic. (c) 2015 AIP Publishing LLC.open11116sciescopu

    Dry semi-continuous anaerobic digestion of food waste in the mesophilic and thermophilic modes: New aspects of sustainable management and energy recovery in South Korea

    Full text link
    © 2016 Elsevier Ltd In this study, parallel, bench-scale, mesophilic and thermophilic, dry, semi-continuous anaerobic digestion (DScAD) of Korea food waste (FW, containing 22% total solids (TS) and 20% volatile solids (VS)) was investigated thoroughly under varying operational conditions, including hydraulic retention times (HRTs) and organic loading rates (OLRs). The aim was to evaluate the start-up, stability, overall removal efficiency, and inhibitory effects of toxic compounds on process performance over a long-term operation lasting 100 days. The results from both digesters indicate that the simultaneous reduction of VS and the production of gas improved as the HRT decreased or the OLR increased. The highest average rates of VS reduction (79.67%) and biogas production (162.14 m3biogas/ton of FW, 61.89% CH4), at an OLR of 8.62 ± 0.34 kg VS/m3day (25 days of HRT), were achieved under thermophilic DScAD. In addition, the average rates of reduction of VS and the production of biogas in thermophilic DScAD were higher by 6.88% and 16.4%, respectively, than were those in mesophilic DScAD. The inhibitory effects of ammonia, H2S, and volatile fatty acids (VFAs) on methane production was not clear from either of the digesters, although, apparently, their concentrations did fluctuate. This fluctuation could be attributed to the self-adaptation of the microbial well. However, digestion that was more stable and faster was observed under thermophilic conditions compared with that under mesophilic conditions. Based on our results, the optimum operational parameters to improve FW treatment and achieve higher energy yields could be determined, expanding the application of DScAD in treating organic wastes

    Influence of thermal hydrolysis pretreatment on physicochemical properties and anaerobic biodegradability of waste activated sludge with different solids content

    Full text link
    © 2018 Elsevier Ltd The influence of thermal hydrolysis pretreatment (THP) on physicochemical properties (pH, total solids, volatile solids, chemical oxygen demand, total nitrogen, ammonium nitrogen, volatile fatty acids, viscosity, and cell morphology) and anaerobic biodegradability of highly concentrated waste activated sludge (WAS) with TS content ranging from 1 to 7% was evaluated at different temperatures ranging from 100 to 220 °C. The biomethane potential (BMP) of the WAS was systematically analyzed and evaluated. Images of its cellular structure were also analyzed. The results indicated that THP is a useful method for solubilizing volatile solids and enhancing CH 4 production regardless of the TS content of the WAS feed. The ultimate CH 4 production determined from the BMP analysis was 313–348 L CH 4 /kg VS (72.6–74.1% CH 4 ) at the optimum THP temperature of 180 °C. The results showed that THP could improve both the capacity and efficiency of anaerobic digestion, even at a high TS content, and could achieve the dual purpose of sludge reduction and higher energy recovery

    A comparison of surgical outcomes between endoscopic and robotically assisted thyroidectomy: the authors’ initial experience

    Get PDF
    Background: The gasless, transaxillary endoscopic thyroidectomy (GTET) offers a distinct advantage over the conventional open operation by leaving no visible neck scar, and in an attempt to improve its ergonomics and surgical outcomes, the robotically assisted thyroidectomy (RAT) was introduced. The RAT uses the same endoscopic route as the GTET but with the assistance of the da Vinci S robotic system. Excellent results for RAT have been reported, but it remains unclear whether RAT offers any potential benefits over GTET. Methods: From June to December 2009, 46 patients underwent endoscopic thyroidectomy. Of these patients, 39 had surgery without the robot (GTET) and 7 had surgery with the robot (RAT). Demographics, surgical indications, operative findings, and postoperative outcomes were compared between the two groups. All the patients were followed up for at least 6 months after surgery. Results: Patient demographics, surgical indications, and extent of resection were similar between the two groups. The median total procedure time was significantly longer for RAT (149 min) than for GTET (100 min; p = 0.018), but the contralateral recurrent laryngeal nerve was more likely to identified in RAT (100%) than in GTET (42.9%; p = 0.070). On the average, GTET needed one more surgical assistant than RAT (1 vs. 0; ppublished_or_final_versionSpringer Open Choice, 21 Feb 201

    Physician and nurse knowledge about patient radiation exposure in the emergency department

    Get PDF
    Background: Imaging methods that use ionizing radiation in emergency departments (EDs) have increased with advances in radiological diagnostic methods. Physician and nurse awareness of the radiation dose in the ED and the associated cancer risks to which the patients are exposed were surveyed with a questionnaire.Methods: A total of 191 subjects in six EDs participated in this study. ED physicians and ED nurses were asked about the risks and the radiation doses of imaging methods ordered in the ED. The differences between the two groups were compared using Student’s t‑test for continuous variables. A Fisher’s exact and Chi‑squared tests were used for categorical variables.Results: A total of 82 ED physicians and 109 ED nurses completed the questionnaire; 38 (46.3%) physicians and 8 (7.3%) nurses correctly answered the question about the chest X‑ray radiation dose. A question about the number of chest X‑rays that is equivalent to the dose of a pelvic X‑ray was answered correctly by 5 (6.1%) physicians and 9 (8.3%) nurses (P = 0.571). Questions regarding abdominal computed tomography (CT), chest CT, brain CT, abdominal ultrasonography, and brain magnetic resonance imaging were answered correctly more frequently by the physician group than the nurse group (P < 0.05). The risk of developing cancer over a lifetime due to a brain CT was correctly answered by 21 (25.6%) physicians and 30 (27.5%) nurses (P = 0.170). A similar question regarding abdominal CT was correctly answered by 21 (25.6%) physicians and 42 (38.5%) nurses (P = 0.127).Conclusions: Knowledge of the radiation exposure of radiology examinations was lower in nurses than physicians, but knowledge was poor in both groups. ED physicians and nurses should be educated about radiation exposure and cancer risks associated with various diagnostic radiological methods.Keywords: Diagnostic imaging, emergencies, radiation dosag

    Metal insulator transition and magnetotransport anomalies in perovskite SrIr0.5Ru0.5O3 thin films

    Get PDF
    We investigated the nature of transport and magnetic properties in SrIr0.5Ru0.5O3 (SIRO), which has characteristics intermediate between a correlated non-Fermi liquid state and an itinerant Fermi liquid state, by growing perovskite thin films on various substrates (e.g., SrTiO3 (001), (LaAlO3)(0.3)(Sr2TaAlO6)(0.7) (001), and LaAlO3 (001)). We observed systematic variation of underlying substrate dependent metal-to-insulator transition temperatures (T-MIT similar to 80K on SrTiO3, similar to 90 K on (LaAlO3)(0.3)(Sr2TaAlO6)(0.7), and similar to 100K on LaAlO3) in resistivity. At temperature 300K >= T >= T-MIT, SIRO is metallic and its resistivity follows a T-3/2 power law, whereas insulating nature at T 25 K, with negative MR proportional to B-1/2 and positive MR proportional to B-2; consistent with the localized-to-normal transport crossover dynamics. Furthermore, observed spin glass like behavior of SIRO on SrTiO3 (001) at T < 25 K in the localized regime validates the hypothesis that (Anderson) localization favors glassy ordering. These remarkable features provide a promising approach for future applications and of fundamental interest in oxide thin films. (C) 2015 AIP Publishing LLC.open1186sciescopu
    corecore