5 research outputs found

    Investigation of Corrosion Inhibition Efficiency of Amazonian Tree Alkaloids Extract for C38 steel in 1M Hydrochloric Media

    No full text
    International audienc

    Calibration gases for existing air quality directive pollutants at limit values (LV)

    No full text
    The European Directive (2008/50/EC) sets up, among other things, the limit values i.e. the maximum allowed concentrations at given time average in the air, for specified pollutants. Calibration of the measurement instruments needs to be performed at regular time intervals. In the framework of an European Joint Research Programme (JRP) named Metrology for Chemical Pollutants in Air (MACPoll) one task aims to provide harmonized dilution methods for air pollutant gases at low concentration for calibration and quality control purposes. The study focuses on the reactive gases nitrogen dioxide and sulphur dioxide at concentration levels corresponding to the limit values given in the European Directive (2008/50/EC). Nitrogen oxide (NO) is studied as well as NO2 because both of them are measured simultaneously for NOx. This work consists in improving the dilution methods for generating calibration standards for SO2, NO, NO2 at limit values and to validate them by an interlaboratory comparison

    International Comparison CCQM-P28: Ozone at Ambient Level

    No full text
    We report a pilot study organized within the Consultative Committee for Amount of Substance (CCQM), in which the ozone reference standards of 23 institutes have been compared to one common reference, the BIPM ozone reference standard, in a series of bilateral comparisons carried out between July 2003 and February 2005. The BIPM, which maintains as its reference standard a standard reference photometer (SRP) developed by the National Institute of Standards and Technology (NIST, United States), served as pilot laboratory. A total of 25 instruments were compared to the common reference standard, either directly (16 comparisons) or via a transfer standard (9 comparisons). The comparisons were made over the ozone mole fraction range 0 nmol/mol to 500 nmol/mol. Two reference methods for measuring ozone mole fractions in synthetic air were compared, thanks to the participation of two institutes maintaining a gas-phase titration system with traceability of measurements to primary gas standards of NO and NO2, while the 23 other instruments were based on UV absorption. In the first instance, each comparison was characterized by the two parameters of a linear equation, as well as their related uncertainties, computed with generalized least-squares regression software. Analysis of these results using the Birge ratio indicated an underestimation of the uncertainties associated with the measurement results of some of the ozone standards, particularly the NIST SRPs. As a final result of the pilot study, the difference from the reference value (BIPM-SRP27 measurement result) and its related uncertainty were calculated for each ozone standard at the two nominal ozone mole fractions of 80 nmol/mol and 420 nmol/mol.JRC.H.4-Transport and air qualit

    International comparison CCQM-K76 : sulfur dioxide in nitrogen

    No full text
    85 p. : il.This Key Comparison is designed to test the capabilities of the participants to measure and certify sulfur dioxide in nitrogen, and will provide supporting evidence for the CMCs of institutes for sulfur dioxide. Also, as sulfur dioxide is designated a core compound, and the 100 ÎŒmol/mol concentration is within the designated core compound concentration range, this comparison is also designed to demonstrate core capabilities of institutes which qualify under the rules of the Gas Analysis Working Group