    Intracranial halo pin penetration causing brain injury secondary to poor halo care technique: a case report and literature review

    Get PDF
    This is a case report of intra cranial penetration by halo pins resulting in cerebritis and fits secondary to incorrect halo care by the patient and his family. Halo pin penetration into the skull with brain injury is itself a rare incident. Previously documented case reports were in patients with a previous cranioplasties and they were highlight the fact that halo not to be used in cranioplasty patients. Cranial penetration of the halo pins has generally been secondary to a fall/medical condition as epilepsy. This incident how ever highlights the fact the halo care itself along with proper techniques used for tightening the halo pins by the carer plays a crucial role in preventing complications such as this

    Incidence of fracture in adjacent levels in patients treated with balloon kyphoplasty: a review of the literature

    Get PDF
    The available evidence suggests that the treatment of painful vertebral compression fractures (VCFs) secondary to osteoporosis or multiple myeloma, by cement augmentation with balloon kyphoplasty (BK), is both safe and effective. However, there is uncertainty in the literature concerning the potential of the procedure to influence the risk for adjacent segment fracture. The aim of this article is to review the available peer-reviewed literature, regarding adjacent vertebral body fractures after kyphoplasty augmentation

    Percutaneous vertebral compression fracture management with polyethylene mesh-contained morcelized allograft bone

    Get PDF
    Study design    A comprehensive systematic review of the literature. Objectives To assess the modern literature on the use of polyethylene mesh-contained morcelized allograft (PMCMA) bone for spinal fusion and vertebral compression fracture management. Summary of background data    There are presently no systematic reviews of PMCMA. Methods    A systematic literature review was performed within three databases (OVID, PubMed, and Google Scholar) using the following keyword search terms: vertebroplasty, kyphoplasty, vertebral compression fracture, percutaneous, polyethylene mesh, and osteoporosis. Results    The initial search identified 764 items, from which two pertinent technique-based articles were identified. There were no published scientific peer-reviewed or case series reporting the clinical results of this technique. The use of PMCMA in the management of vertebral compression fractures (VCFs) is similar to vertebroplasty and kyphoplasty. This novel, percutaneous system uses the properties of granular mechanics to establish a conforming, semirigid graft that is purportedly capable of withstanding physiologic loads. Discussion    PMCMA is a novel percutaneous technology for the management of VCF and possibly for use as a conforming interbody graft. The available published literature lacks outcome data of the use of PMCMA. Careful, independent research is needed to assess the viability of this technology and its long-term results

    Symptomatic intracranial abscess after treating lower cervical spine fracture with halo vest: a case report and review of literature

    Get PDF
    We present the case of a nineteen year old male, who sustained a fracture of anterior-superior surface of C7, combined with anterior subluxation at the level of C6–C7 vertebrae. After x-ray and CT examination, he was treated conservatively by a Halo-vest. After mobilization, the patient was discharged from the hospital with instructions to visit the outpatient's clinic at regular bases

    Primary pyogenic spondylitis following kyphoplasty: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Only ten cases of primary pyogenic spondylitis following vertebroplasty have been reported in the literature. To the best of our knowledge, we present the first reported case of primary pyogenic spondylitis and spondylodiscitis caused by kyphoplasty.</p> <p>Case presentation</p> <p>A 72-year old Caucasian man with an osteoporotic compression fracture of the first lumbar vertebra after kyphoplasty developed sensory incomplete paraplegia below the first lumbar vertebra. This was caused by myelon compression following pyogenic spondylitis with a psoas abscess. Computed tomography guided aspiration of the abscess cavity yielded group C <it>Streptococcus</it>. The psoas abscess was percutaneously drained and laminectomy and posterior instrumentation with an internal fixator from the eleventh thoracic vertebra to the fourth lumbar vertebra was performed. In a second operation, corpectomy of the first lumbar vertebra with cement removal and fusion from the twelfth thoracic vertebra to the second lumbar vertebra with a titanium cage was performed. Six weeks postoperatively, the patient was pain free with no neurologic deficits or signs of infection.</p> <p>Conclusion</p> <p>Pyogenic spondylitis is an extremely rare complication after kyphoplasty. When these patients develop recurrent back pain postoperatively, the diagnosis of pyogenic spondylitis must be considered.</p

    Balloon kyphoplasty in malignant spinal fractures: a systematic review and meta-analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Spinal fractures are a common source of morbidity in cancer patients. Balloon Kyphoplasty (BKP) is a minimally invasive procedure designed to stabilize fractures and correct vertebral deformities. We performed a meta-analysis to determine the efficacy and safety of BKP for spinal fractures in cancer patients.</p> <p>Methods</p> <p>We searched several electronic databases up to September 2008 and the reference lists of relevant publications for studies reporting on BKP in patients with spinal fractures secondary to osteolytic metastasis and multiple myeloma. Outcomes sought included pain relief, functional capacity, quality of life, vertebral height, kyphotic angle and adverse events. Studies were assessed for methodological bias, and estimates of effect were calculated using a random-effects model. Potential reasons for heterogeneity were explored.</p> <p>Results</p> <p>The literature search revealed seven relevant studies published from 2003 to 2008, none of which were randomized trials. Analysis of those studies indicated that BKP resulted in less pain and better functional outcomes, and that these effects were maintained up to 2 years post-procedure. While BKP also improved early vertebral height loss and spinal deformity, these effects were not long-term. No serious procedure-related complications were described. Clinically asymptomatic cement leakage occurred in 6% of all treated levels, and new vertebral fractures in 10% of patients. While there is a lack of studies comparing BKP to other interventions, some data suggested that BKP provided similar pain relief as vertebroplasty and a lower cement leakage rate.</p> <p>Conclusion</p> <p>It appears that there is level III evidence showing BKP is a well-tolerated, relatively safe and effective technique that provides early pain relief and improved functional outcomes in patients with painful neoplastic spinal fractures. BKP also provided long-term benefits in terms of pain and disability. However, the methodological quality of the original studies prevents definitive conclusions being drawn. Further investigation into the use of BKP for spinal fractures in cancer patients is warranted.</p