67 research outputs found
Clinical Outcomes by Race and Ethnicity in the Systolic Blood Pressure Intervention Trial (SPRINT): A Randomized Clinical Trial
BACKGROUND:
The Systolic Blood Pressure Intervention Trial (SPRINT) showed that targeting a systolic blood pressure (SBP) of ≤ 120 mm Hg (intensive treatment) reduced cardiovascular disease (CVD) events compared to SBP of ≤ 140 mm Hg (standard treatment); however, it is unclear if this effect is similar in all racial/ethnic groups.
METHODS:
We analyzed SPRINT data within non-Hispanic White (NHW), non-Hispanic Black (NHB), and Hispanic subgroups to address this question. High-risk nondiabetic hypertensive patients (N = 9,361; 30% NHB; 11% Hispanic) 50 years and older were randomly assigned to intensive or standard treatment. Primary outcome was a composite of the first occurrence of a myocardial infarction, acute coronary syndrome, stroke, decompensated heart failure, or CVD death.
RESULTS:
Average postbaseline SBP was similar among NHW, NHB, and Hispanics in both treatment arms. Hazard ratios (HRs) (95% confidence interval) (intensive vs. standard treatment groups) for primary outcome were 0.70 (0.57–0.86), 0.71 (0.51–0.98), 0.62 (0.33–1.15) (interaction P value = 0.85) in NHW, NHB, and Hispanics. CVD mortality HRs were 0.49 (0.29–0.81), 0.77 (0.37–1.57), and 0.17 (0.01–1.08). All-cause mortality HRs were 0.61 (0.47–0.80), 0.92 (0.63–1.35), and 1.58 (0.73–3.62), respectively. A test for differences among racial/ethnic groups in the effect of treatment assignment on all-cause mortality was not significant (Hommel-adjusted P value = 0.062) after adjustment for multiple comparisons.
CONCLUSION:
Targeting a SBP goal of ≤ 120 mm Hg compared to ≤ 140 mm Hg led to similar SBP control and was associated with similar benefits and risks among all racial ethnic groups, though NHBs required an average of ~0.3 more medications
The association between Self-Reported Medication Adherence scores and systolic blood pressure control: a SPRINT baseline data study
We examined baseline data from the Systolic Blood Pressure Intervention Trial (SPRINT) to investigate whether medication adherence, measured by the 8-item Morisky Medication Adherence Scale (MMAS-8), was associated with systolic blood pressure (SBP) and whether MMAS-8 score and number of antihypertensive medications interacted in influencing SBP. A total of 8435 SPRINT participants were included: 21.2% had low adherence (MMAS-8: 160 mm Hg in 8.8%. In multivariable regression, medium vs. low adherence weakly associated with lower SBP (odds ratio: 1.17; confidence interval: 1.04, 1.31). SPRINT eligibility criteria should be considered when interpreting results. Efforts to understand and enhance adherence are crucial to improve population health, and using self-report instruments might be considered for predicting treatment adherence and response in future efficacy trials and for identifying patients for adherence support in clinical practice
Recommended from our members
Measuring vascular reactivity with resting-state blood oxygenation level-dependent (BOLD) signal fluctuations: A potential alternative to the breath-holding challenge?
Measurement of the ability of blood vessels to dilate and constrict, known as vascular reactivity, is often performed with breath-holding tasks that transiently raise arterial blood carbon dioxide (P
CO
) levels. However, following the proper commands for a breath-holding experiment may be difficult or impossible for many patients. In this study, we evaluated two approaches for obtaining vascular reactivity information using blood oxygenation level-dependent signal fluctuations obtained from resting-state functional magnetic resonance imaging data: physiological fluctuation regression and coefficient of variation of the resting-state functional magnetic resonance imaging signal. We studied a cohort of 28 older adults (69 ± 7 years) and found that six of them (21%) could not perform the breath-holding protocol, based on an objective comparison with an idealized respiratory waveform. In the subjects that could comply, we found a strong linear correlation between data extracted from spontaneous resting-state functional magnetic resonance imaging signal fluctuations and the blood oxygenation level-dependent percentage signal change during breath-holding challenge ( R
= 0.57 and 0.61 for resting-state physiological fluctuation regression and resting-state coefficient of variation methods, respectively). This technique may eliminate the need for subject cooperation, thus allowing the evaluation of vascular reactivity in a wider range of clinical and research conditions in which it may otherwise be impractical
- …