14 research outputs found

    Metal fractionation in sediments of the Sergipe River, northeast, Brazil

    Get PDF
    The sequential extraction procedure proposed by the European Community Bureau of Reference (BCR) was applied for the fractionation of Cd, Cr, Cu, Ni, Pb and Zn in sediments from the Sergipe Estuary, Brazil. The method showed satisfactory recoveries, detection limits and standard deviations for trace metals determinations in sediment samples. Cd was the metal with the greatest percentage in the exchangeable fraction. Pb and Ni were present mainly in the reducible and oxidizable fractions. Cr, Cu and Zn were predominantly associated with the residual fraction. The order of mobility of metals extracted was Pb > Cd > Ni > Cu > Cr > Zn. According to the risk assessment code (RAC), the sediments showed low to medium risk for all metals. _________________________________________________________________________________________ RESUMO: O procedimento de extração seqüencial proposto pelo European Community Bureau of Reference (BCR) foi empregado para o fracionamento de Cd, Cr, Cu, Ni, Pb e Zn em sedimentos do estuário do Rio Sergipe, Brasil. O método empregado apresentou-se adequado com limite de detecção e desvio padrão aceitável para a determinação de metais em amostras de sedimentos. Cd foi o metal com maior percentagem na fração extraível. Ni e Pb estão presentes principalmente nas frações oxidável e redutível. Cr, Cu e Zn foram encontrados predominantemente na fração residual. A ordem de mobilidade dos metais extraídos foi Pb > Cd > Ni > Cu > Cr > Zn. De acordo com o código de avaliação de risco (RAC), as amostras de sedimentos mostraram risco baixo a médio para todos os metais analisados

    Trajetórias da Educomunicação nas Políticas Públicas e a Formação de seus Profissionais

    Get PDF
    Esta obra é composta com os trabalhos apresentados no primeiro subtema, TRAJETÓRIA – Educação para a Comunicação como Política pública, nas perspectivas da Educomunicação e da Mídia-Educação, do II Congresso Internacional de Comunicação e Educação. Os artigos pretendem propiciar trocas de informações e produzir reflexões com os leitores sobre os caminhos percorridos, e ainda a percorrer, tendo como meta a expansão e a legitimação das práticas educomunicativas e/ou mídia-educativas como política pública para o atendimento à formação de crianças, adolescentes, jovens e adultos, no Brasil e no mundo

    Rev. Bras. Med. Ocup

    No full text
    Objetivo: Avaliar o nivel de exposição ocupacional em uma metalúrgica de chumbo, através da determinação dos indicadores biológicos de exposição e efeito, com objetivo de estabelecer um mapeamento das áreas de risco dentro da planta industrial..

    Preconcentration and Determination of Copper and Zinc in Natural Water Samples by ICP-AES After Complexation and Sorption on Amberlite XAD-2

    No full text
    The present paper describes a procedure for separation, preconcentration and sequential determination of trace amounts of copper and zinc in natural water samples, by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES). The proposed method is based on the complexation of copper(II) and zinc(II) ions by 1-(2-thiazolylazo)-2-naphthol (TAN) and sorption on to Amberlite XAD-2 resin. Parameters such as: TAN amount, pH effect on the complexation and sorption of TAN complexes, agitation time for complete sorption, concentration of metal ion, mass of Amberlite XAD-2, desorption of metal ions from XAD-2 resin and sample volume were studied. The results demonstrated that the copper(II) and zinc(II) ions, in the range of 0.10 to 100.00 mug, contained in a solution sample volume of 400 mL, in the pH range of 5.7 to 8.3, on the form of TAN complexes had been quantitatively retained on to XAD-2 resin. The shaking time required for sorption is 1 h using a resin mass of 1.4 g. The solution for determination of copper and zinc by ICP-AES is obtained, after desorption of the ions from the XAD-2 resin, using 5 mL of 2 mol L-1 hydrochloric acid and shaking the system for 5 min. The procedure was applied to the determination of copper and zinc in several natural water samples. The standard addition technique was applied and the obtained recoveries revealed that the proposed procedure has a good accuracy. A high enrichment factor (80) and simplicity are the main advantages in this analytical protocol
    corecore