38 research outputs found

    Development of a Two-Dimensional Gaseous Detector for Energy-Selective Neutron Radiography

    Get PDF
    AbstractEnergy-selective neutron radiography is a new method for studying the fine structure of heavy materials by using pulsed neutron sources. To perform such radiography, precise measurements of temporal information and twodimensional position are essential. Therefore, we developed a gaseous neutron detector using the gas electron multiplier (GEM). In addition, to detect neutrons, a single surface of an aluminium cathode plate and both surfaces of two GEM foils were coated with boron-10. Two normal GEM foils were stacked in a chamber for gas amplification. An anode plate with two-dimensional strips (0.8-mm pitch) was mounted in order to precisely reconstruct neutron incident positions. To allow high-speed data transfer, a compact readout system with new application-specific integrated circuit (ASIC) chips and a field programmable gate array (FPGA) was developed. Finally, several beam tests were conducted with pulsed neutron sources and two interesting applications were demonstrated

    Male Breast Cancer Originating in an Accessory Mammary Gland in the Axilla: A Case Report

    Get PDF
    Carcinoma of an accessory mammary gland is an extremely rare tumor. A 61-year-old male patient presented with a hard mass measuring 85 mm × 51 mm in the left axilla. Incisional biopsy histopathologically showed an adenocarcinoma compatible with breast carcinoma originating in an accessory mammary gland. Systemic examinations revealed no evidence of malignant or occult primary lesion in the bilateral mammary glands or in other organs. Neoadjuvant chemotherapy was performed for the locally advanced axillary tumor and reduced the tumor to 55 mm in size, and, then, he could undergo complete resection with a negative surgical margin in combination with reconstructive surgery to fill the resulting skin defect with a local flap of the latissimus dorsi muscle. The patient has presented with no metastatic lesion in four years since the operation. This unusual case shows that neoadjuvant chemotherapy is an effective and tolerated therapy for advanced accessory breast cancer in the axilla

    Primary Chest Wall Abscess Mimicking a Breast Tumor That Occurred after Blunt Chest Trauma: A Case Report

    Get PDF
    Primary chest wall abscess occurring after blunt chest trauma is rare. We present the case of a 50-year-old woman who presented with a swelling in her left breast. The patient had experienced blunt chest trauma 2 months back. Needle aspiration revealed pus formation in the patient’s chest. Computed tomography revealed a mass in the lower region of the left mammary gland, with thickening of the parietal pleura and skin and fracture of the fifth rib under the abscess. Following antibiotic administration and irrigation of the affected region, surgical debridement was performed. During surgery, we found that the pectoralis major muscle at the level of the fifth rib was markedly damaged, although the necrotic tissue did not contact the mammary gland. We diagnosed the lesion as a chest wall abscess that occurred in response to blunt chest trauma. Her postoperative course was uneventful. There has been no recurrence for six months after surgery

    Search for Theta+ via K+p -> pi+X reaction with a 1.2 GeV/c K+ beam

    Get PDF
    The Theta+ was searched for via the K+p -> pi+X reaction using the 1.2 GeV/c K+ beam at the K6 beam line of the KEK-PS 12 GeV Proton Synchrotron. In the missing mass spectrum of the K+p -> pi+X reaction, no clear peak structure was observed. Therefore a 90 % C.L. upper limit of 3.5 ub/sr was derived for the differential cross section averaged over 2degree to 22degree in the laboratory frame of the K+p -> pi+Theta+ reaction. This upper limit is much smaller than the theoretical calculation for the t-channel process where a K0* is exchanged. From the present result, either the t-channel process is excluded or the coupling constant of g_{K*N\Theta} is quite small.Comment: 11pages, 13figure

    Beam and SKS spectrometers at the K1.8 beam line

    Get PDF
    High-resolution spectrometers for both incident beams and scattered particles have been constructed at the K1.8 beam line of the Hadron Experimental Facility at J-PARC. A point-to-point optics is realized between the entrance and exit of QQDQQ magnets for the beam spectrometer. Fine-pitch wire chamber trackers and hodoscope counters are installed in the beam spectrometer to accept a high rate beam up to 107 Hz. The superconducting kaon spectrometer for scattered particles was transferred from KEK with modifications to the cryogenic system and detectors. A missing-mass resolution of 1.9 ± 0.1 MeV/c2 (FWHM) was achieved for the ∑ peaks of (π±, K+) reactions on a proton target in the first physics run of E19 in 2010
    corecore