1,428 research outputs found

    Vibrational analysis of d-PCL(530)/siloxane based hybrids doped with two lithium salts

    Get PDF
    Published online: 22 May 2013The present study has been focused on environmentally friendly sol-gel derived electrolytes based on a di-urethane cross-linked d-PCL(530)/siloxane network (where d represents di, PCL identifies the poly(Δ–caprolactone) biopolymer and 530 is the average molecular weight in g.mol-1) doped with a wide range of concentration of lithium perchlorate (LiClO4) and lithium bis(trifluoromethanesulfonyl)imide (LiTFSI). Fourier Transform Infrared and Raman (FT-IR and FT-Raman, respectively) spectroscopies have been applied to evaluate the extent of ionic association. Characteristic bands of the PCL(530) segments, of the urethane cross-links and of the anions have been examined to gain insight into the cation/biopolymer, cation/anion and cation/cross-link interactions. In both electrolyte systems “free” ions and contact ions have been identified. The addition of salt modifies the hydrogen-bonded array of the host matrix, causing the destruction/formation of the urethane/urethane aggregates.Fundação para a CiĂȘncia e a Tecnologia (FCT

    Validation of non-invasive central blood pressure devices: ARTERY Society task force consensus statement on protocol standardization

    Get PDF
    The original Riva-Rocci method to measure blood pressure (BP) using a cuff at the upper arm assumed the pressure obtained by this technique was a good proxy for central aortic BP.1,2 The clinical (prognostic) importance of brachial cuff BP is undeniable for both the assessment of cardiovascular risk associated with elevated BP and the benefits of treatment-induced BP reduction.3 However, it is also generally appreciated that peripheral artery systolic BP (SBP; brachial or radial artery) may be an inaccurate substitute for central SBP.4 This has been reported in human studies using intra-arterial catheterization of peripheral and central arteries.5–8 There may also be a discrepancy between peripheral and central BP responses to vasoactive drugs.9 These findings are corroborated in larger studies using non-invasive central aortic BP methods,10–13 and, while yet to be fully adopted in clinical practice, an independent prognostic value of central BP has been demonstrated.14–16 Altogether, there is a growing interest among clinicians towards improving risk estimates by using devices that provide more accurate measures of central aortic BP than those provided by current brachial cuff BP methods. Many non-invasive devices have been developed that purport to estimate central BP from different peripheral artery sites (e.g. radial, brachial, carotid arteries) using different principles of recording the pressure or surrogate signals (e.g. applanation tonometry, oscillometry, ultrasound, or magnetic resonance imaging) and different calibration methods to derive central BP. Since upper arm cuff-based devices to estimate central BP are more clinically appealing, in recent years several companies have developed such devices using a variety of techniques (e.g. oscillometric sub-diastolic or supra-systolic waveform analysis with generalized transfer functions), which employ a variety of signal processing steps to estimate central BP from peripheral signals.17,18 Yet, with no standardized guidelines,17 the accuracy testing of these new devices (as well as the preceding devices) has not been undertaken in a uniform fashion with comparable protocols, emphasizing the need for guidance in this field.19–22 An international task force was convened to address this situation

    A fresh look at the evolution and diversification of photochemical reaction centers

    Get PDF
    In this review, I reexamine the origin and diversification of photochemical reaction centers based on the known phylogenetic relations of the core subunits, and with the aid of sequence and structural alignments. I show, for example, that the protein folds at the C-terminus of the D1 and D2 subunits of Photosystem II, which are essential for the coordination of the water-oxidizing complex, were already in place in the most ancestral Type II reaction center subunit. I then evaluate the evolution of reaction centers in the context of the rise and expansion of the different groups of bacteria based on recent large-scale phylogenetic analyses. I find that the Heliobacteriaceae family of Firmicutes appears to be the earliest branching of the known groups of phototrophic bacteria; however, the origin of photochemical reaction centers and chlorophyll synthesis cannot be placed in this group. Moreover, it becomes evident that the Acidobacteria and the Proteobacteria shared a more recent common phototrophic ancestor, and this is also likely for the Chloroflexi and the Cyanobacteria. Finally, I argue that the discrepancies among the phylogenies of the reaction center proteins, chlorophyll synthesis enzymes, and the species tree of bacteria are best explained if both types of photochemical reaction centers evolved before the diversification of the known phyla of phototrophic bacteria. The primordial phototrophic ancestor must have had both Type I and Type II reaction centers

    Foundations of Black Hole Accretion Disk Theory

    Get PDF
    This review covers the main aspects of black hole accretion disk theory. We begin with the view that one of the main goals of the theory is to better understand the nature of black holes themselves. In this light we discuss how accretion disks might reveal some of the unique signatures of strong gravity: the event horizon, the innermost stable circular orbit, and the ergosphere. We then review, from a first-principles perspective, the physical processes at play in accretion disks. This leads us to the four primary accretion disk models that we review: Polish doughnuts (thick disks), Shakura-Sunyaev (thin) disks, slim disks, and advection-dominated accretion flows (ADAFs). After presenting the models we discuss issues of stability, oscillations, and jets. Following our review of the analytic work, we take a parallel approach in reviewing numerical studies of black hole accretion disks. We finish with a few select applications that highlight particular astrophysical applications: measurements of black hole mass and spin, black hole vs. neutron star accretion disks, black hole accretion disk spectral states, and quasi-periodic oscillations (QPOs).Comment: 91 pages, 23 figures, final published version available at http://www.livingreviews.org/lrr-2013-

    Quality of reporting internal and external validity data from randomized controlled trials evaluating stents for percutaneous coronary intervention

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Stents are commonly used to treat patients with coronary artery disease. However, the quality of reporting internal and external validity data in published reports of randomised controlled trials (RCTs) of stents has never been assessed.</p> <p>The objective of our study was to evaluate the quality of reporting internal and external validity data in published reports of RCTs assessing the stents for percutaneous coronary interventions.</p> <p>Methods</p> <p>A systematic literature review was conducted. Reports of RCTs assessing stents for percutaneous coronary interventions indexed in MEDLINE and the Cochrane Central Register of Controlled Trials and published between January 2003 and September 2008 were selected. A standardized abstraction form was used to extract data. All analyses were adjusted for the effect of clustering articles by journal.</p> <p>Results</p> <p>132 articles were analyzed. The generation of the allocation sequence was adequate in 58.3% of the reports; treatment allocation was concealed in 34.8%. Adequate blinding was reported in one-fifth of the reports. An intention-to-treat analysis was described in 79.5%. The main outcome was a surrogate angiographic endpoint in 47.0%. The volume of interventions per center was described in two reports. Operator expertise was described in five (3.8%) reports. The quality of reporting was better in journals with high impact factors and in journals endorsing the CONSORT statement.</p> <p>Conclusion</p> <p>The current reporting of results of RCTs testing stents needs to be improved to allow readers to appraise the risk of bias and the applicability of the results.</p

    Effects of a Caffeine-Containing Energy Drink on Simulated Soccer Performance

    Get PDF
    [Background] To investigate the effects of a caffeine-containing energy drink on soccer performance during a simulated game. A second purpose was to assess the post-exercise urine caffeine concentration derived from the energy drink intake. [Methodology/Principal Findings] Nineteen semiprofessional soccer players ingested 630±52 mL of a commercially available energy drink (sugar-free Red BullÂź) to provide 3 mg of caffeine per kg of body mass, or a decaffeinated control drink (0 mg/kg). After sixty minutes they performed a 15-s maximal jump test, a repeated sprint test (7×30 m; 30 s of active recovery) and played a simulated soccer game. Individual running distance and speed during the game were measured using global positioning satellite (GPS) devices. In comparison to the control drink, the ingestion of the energy drink increased mean jump height in the jump test (34.7±4.7 v 35.8±5.5 cm; P<0.05), mean running speed during the sprint test (25.6±2.1 v 26.3±1.8 km · h−1; P<0.05) and total distance covered at a speed higher than 13 km · h−1 during the game (1205±289 v 1436±326 m; P<0.05). In addition, the energy drink increased the number of sprints during the whole game (30±10 v 24±8; P<0.05). Post-exercise urine caffeine concentration was higher after the energy drink than after the control drink (4.1±1.0 v 0.1±0.1 ”g · mL−1; P<0.05). [Conclusions/significance] A caffeine-containing energy drink in a dose equivalent to 3 mg/kg increased the ability to repeatedly sprint and the distance covered at high intensity during a simulated soccer game. In addition, the caffeinated energy drink increased jump height which may represent a meaningful improvement for headers or when players are competing for a ball
    • 

    corecore