48 research outputs found

    Buttressing staples with cholecyst-derived extracellular matrix (CEM) reinforces staple lines in an ex vivo peristaltic inflation model

    Get PDF
    This is the author's accepted manuscript. The final published article is available from the link below. Copyright @ Springer Science + Business Media, LLC 2008Background - Staple line leakage and bleeding are the most common problems associated with the use of surgical staplers for gastrointestinal resection and anastomotic procedures. These complications can be reduced by reinforcing the staple lines with buttressing materials. The current study reports the potential use of cholecyst-derived extracellular matrix (CEM) in non-crosslinked (NCEM) and crosslinked (XCEM) forms, and compares their mechanical performance with clinically available buttress materials [small intestinal submucosa (SIS) and bovine pericardium (BP)] in an ex vivo small intestine model. Methods - Three crosslinked CEM variants (XCEM0005, XCEM001, and XCEM0033) with different degree of crosslinking were produced. An ex vivo peristaltic inflation model was established. Porcine small intestine segments were stapled on one end, using buttressed or non-buttressed surgical staplers. The opened, non-stapled ends were connected to a peristaltic pump and pressure transducer and sealed. The staple lines were then exposed to increased intraluminal pressure in a peristaltic manner. Both the leak and burst pressures of the test specimens were recorded. Results - The leak pressures observed for non-crosslinked NCEM (137.8 ± 22.3 mmHg), crosslinked XCEM0005 (109.1 ± 14.1 mmHg), XCEM001 (150.1 ± 16.0 mmHg), XCEM0033 (98.8 ± 10.5 mmHg) reinforced staple lines were significantly higher when compared to non-buttressed control (28.3 ± 10.8 mmHg) and SIS (one and four layers) (62.6 ± 11.8 and 57.6 ± 12.3 mmHg, respectively) buttressed staple lines. NCEM and XCEM were comparable to that observed for BP buttressed staple lines (138.8 ± 3.6 mmHg). Only specimens with reinforced staple lines were able to achieve high intraluminal pressures (ruptured at the intestinal mesentery), indicating that buttress reinforcements were able to withstand pressure higher than that of natural tissue (physiological failure). Conclusions - These findings suggest that the use of CEM and XCEM as buttressing materials is associated with reinforced staple lines and increased leak pressures when compared to non-buttressed staple lines. CEM and XCEM were found to perform comparably with clinically available buttress materials in this ex vivo model.Enterprise Irelan

    Single- versus two- layer intestinal anastomosis: a meta-analysis of randomized controlled trials

    Get PDF
    BACKGROUND: To compare single- with two- layer intestinal anastomosis after intestinal resection: a meta-analysis of randomized controlled trials. METHODS: Randomized controlled trials comparing single- with two-layer intestinal anastomosis were identified using a systematic search of Medline, Embase and the Cochrane Library Databases covering articles published from 1966 to 2004. Outcome of primary interest was postoperative leak. A risk ratio for trial outcomes and weighted pooled estimates for data were calculated. A fixed-effect model weighted using Mantel-Haenszel methods and a random-effect model using DerSimonian-Laird methods were employed. RESULTS: Six trials were analyzed, comprising 670 participants (single-layer group, n = 299; two-layer group, n = 371). Data on leaks were available from all included studies. Combined risk ratio using DerSimonian-Laird methods was 0.91 (95% CI = 0.49 to 1.69), and indicated no significant difference. Inter-study heterogeneity was significant (χ(2 )= 10.5, d.f. = 5, p = 0.06). CONCLUSION: No evidence was found that two-layer intestinal anastomosis leads to fewer post-operative leaks than single layer. Considering duration of the anastomosis procedure and medical expenses, single-layer intestinal anastomosis appears to represent the optimal choice for most surgical situations

    Tension of knotted surgical sutures shows tissue specific rapid loss in a rodent model

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Every surgical suture compresses the enclosed tissue with a tension that depends from the knotting force and the resistance of the tissue. The aim of this study was to identify the dynamic change of applied suture tension with regard to the tissue specific cutting reaction.</p> <p>Methods</p> <p>In rabbits we placed single polypropylene sutures (3/0) in skin, muscle, liver, stomach and small intestine. Six measurements for each single organ were determined by tension sensors for 60 minutes. We collected tissue specimens to analyse the connective tissue stability by measuring the collagen/protein content.</p> <p>Results</p> <p>We identified three phases in the process of suture loosening. The initial rapid loss of the first phase lasts only one minute. It can be regarded as cutting through damage of the tissue. The percentage of lost tension is closely related to the collagen content of the tissue (r = -0.424; p = 0.016). The second phase is characterized by a slower decrease of suture tension, reflecting a tissue specific plastic deformation. Phase 3 is characterized by a plateau representing the remaining structural stability of the tissue. The ratio of remaining tension to initial tension of phase 1 is closely related to the collagen content of the tissue (r = 0.392; p = 0.026).</p> <p>Conclusions</p> <p>Knotted non-elastic monofilament sutures rapidly loose tension. The initial phase of high tension may be narrowed by reduction of the surgeons' initial force of the sutures' elasticity to those of the tissue. Further studies have to confirm, whether reduced tissue compression and less local damage permits improved wound healing.</p

    Measures of frailty in population-based studies: An overview

    Get PDF
    Although research productivity in the field of frailty has risen exponentially in recent years, there remains a lack of consensus regarding the measurement of this syndrome. This overview offers three services: first, we provide a comprehensive catalogue of current frailty measures; second, we evaluate their reliability and validity; third, we report on their popularity of use