782 research outputs found

    On Epstein's trajectory model of non-relativistic quantum mechanics

    Full text link
    In 1952 Bohm presented a theory about non-relativistic point-particles moving along deterministic trajectories and showed how it reproduces the predictions of standard quantum theory. This theory was actually presented before by de Broglie in 1926, but Bohm's particular formulation of the theory inspired Epstein to come up with a different trajectory model. The aim of this paper is to examine the empirical predictions of this model. It is found that the trajectories in this model are in general very different from those in the de Broglie-Bohm theory. In certain cases they even seem bizarre and rather unphysical. Nevertheless, it is argued that the model seems to reproduce the predictions of standard quantum theory (just as the de Broglie-Bohm theory).Comment: 12 pages, no figures, LaTex; v2 minor improvement

    Large-scale survey of seasonal drinking water quality in Malawi using in situ tryptophan-like fluorescence and conventional water quality indicators

    Get PDF
    Faecally-contaminated drinking water is a risk to human health, with the greatest risks to those living in developing countries. UN Sustainable Development Goal 6 aims to address this issue. Tryptophan-like fluorescence (TLF) shows potential as a rapid method for detecting microbial contamination in drinking water, which could reduce the spread of waterborne diseases. This study is the first to investigate the effectiveness of TLF for a large-scale survey using a randomised, spot-sampling approach. The large-scale survey took place in Malawi, sub-Saharan Africa, in the dry season (n = 183). A subset of sources were revisited at the end of the following wet season (n = 41). The effectiveness of TLF was assessed by comparing TLF results to thermotolerant coliforms (TTC), humic-like fluorescence (HLF), inorganic hydrochemical data and sanitary risk scores. The most prominent differences in microbial water quality were observed between source types, with little variation between districts and seasons. TLF, TTCs, turbidity and sanitary risk scores were all elevated at alternative sources (shallow wells and tap stands) compared to hand-pumped boreholes. In the dry season, 18% of hand-pumped boreholes showed TTC contamination, which increase to 21% in the wet season. Groundwater recharge processes are likely responsible for seasonal variability of inorganic hydrochemistry at hand-pumped boreholes. TLF was able to distinguish no and low WHO risk classes (TTC 0–9 cfu/100 mL) from medium, high and very high risk classes (TTC 10 – >1000 cfu/100 mL). TLF failed to distinguish between no and low risk classes, which limits the use of TLF for assessing water quality to drinking water standards. This dataset indicates that HLF may raise baseline TLF for samples with low TLF values, increasing false positives. Therefore, TLF is better suited as a rapid high-level water quality screening tool to assess moderate and high levels of faecal contamination

    Tryptophan-like fluorescence as a high-level screening tool for detecting microbial contamination in drinking water

    Get PDF
    Regular monitoring of drinking water quality is vital to identify contamination of potable water supplies. Testing for microbial contamination is important to prevent transmission of waterborne disease, but establishing and maintaining a water quality monitoring programme requires sustained labour, consumables and resources. In low resource settings such as developing countries, this can prove difficult, but measuring microbial contamination is listed as a requirement of reaching the UN's Sustainable Development Goal 6 for water and sanitation. A nine-month water quality monitoring programme was conducted in rural Malawi to assess the suitability of tryptophan-like fluorescence (TLF), an emerging method for rapidly detecting microbial contamination, as a drinking water quality monitoring tool. TLF data was compared with thermotolerant coliforms (TTCs, E. coli) and inorganic hydrochemical parameters. A large (n = 235) temporal dataset was collected from five groundwater drinking water sources, with samples collected once or twice weekly depending on the season. The results show that TLF can indicate a broader contamination risk but is not as sensitive to short term variability when compared to other faecal indicators. This is likely due to a broad association of TLF with elevated DOC concentrations from a range of different sources. Elevated TLF may indicate preferential conditions for the persistence of TTCs and/or E. coli, but not necessarily a public health risk from microbial contamination. TLF is therefore a more precautionary risk indicator than microbial culturing techniques and could prove useful as a high-level screening tool for initial risk assessment. For widespread use of TLF to be successful, standardisation of TLF values associated with different levels of risk is required, however, this study highlights the difficulties of equating TLF thresholds to TTCs or E. coli data because of the influence of DOC/HLF on the TLF signal

    Tryptophan-like fluorescence as a measure of microbial contamination risk in groundwater

    Get PDF
    Microbial water quality is frequently assessed with a risk indicator approach that relies on Escherichia coli. Relying exclusively on E. coli is limiting, particularly in low-resource settings, and we argue that risk assessments could be improved by a complementary parameter, tryptophan-like fluorescence (TLF). Over two campaigns (June 2016 and March 2017) we sampled 37 water points in rural Kwale County, Kenya for TLF, E. coli and thermotolerant coliforms (total n = 1,082). Using three World Health Organization defined classes (very high, high, and low/intermediate), risk indicated by TLF was not significantly different from risk indicated by E. coli (p=0.85). However, the TLF and E. coli risk classifications did show disagreement, with TLF indicating higher risk for 14% of samples and lower risk for 13% of samples. Comparisons of duplicate/replicate results demonstrated that precision is higher for TLF (average relative percent difference of duplicates = 14%) compared to culture-based methods (average RPD of duplicates >= 26%). Additionally, TLF sampling is more practical because it requires less time and resources. Precision and practicality make TLF well-suited to high-frequency sampling in low resource contexts. Interpretation and interference challenges are minimised when TLF is measured in groundwaters, which typically have low dissolved organic carbon, relatively consistent temperature, negligible turbidity and pH between 5 and 8. TLF cannot be used as a proxy for E. coli on an individual sample basis, but it can add value to groundwater risk assessments by improving prioritization of sampling and by increasing understanding of spatiotemporal variability

    The UK risk assessment scheme for all non-native species

    Get PDF
    1. A pest risk assessment scheme, adapted from the EPPO (European and Mediterranean Plant Protection Organisation) scheme, was developed to assess the risks posed to UK species, habitats and ecosystems by non-native taxa. 2. The scheme provides a structured framework for evaluating the potential for non-native organisms, whether intentional or unintentional introductions, to enter, establish, spread and cause significant impacts in all or part of the UK. Specialist modules permit the relative importance of entry pathways, the vulnerability of receptors and the consequences of policies to be assessed and appropriate risk management options to be selected. Spreadsheets for summarising the level of risk and uncertainty, invasive attributes and economic impact were created. In addition, new methods for quantifying economic impact and summarising risk and uncertainty were explored. 3. Although designed for the UK, the scheme can readily be applied elsewhere

    A nervous disorder in cattle, caused by the plants Ficus ingens var. ingens and Ficus cordata subsp. salicifolia

    Get PDF
    Two outbreaks of neurotoxicoses are reported in cattle browsing on the leaves of Ficus spp. In the first outbreak, three animals died and one became ill. A sheep developed severe nervous signs, including tetanic spasms, when dosed with the leaves of Ficus ingens var. ingens from the toxic camp where the cattle had died. The second outbreak resulted in the death of 12 heifers within 48 h of ingestion of the leaves of F. cordata subsp. salicifolia. Clinical signs included hyperaesthesia, ataxia, muscle tremors and paddling motions while in lateral recumbency. Similar signs were reproduced by drenching the incriminated leaves to a steer. The sheep dosed with F. ingens var. ingens and two cattle, one of which had died during the second outbreak and the steer drenched with F. cordata subsp. salicifolia, were necropsied. Light microscopical examination consistently revealed oedema of the central nervous system. In the steer, focal demyelination was evident in localized areas of the brain and spinal cord. Liver lesions ranged from mild degeneration to focal disseminated necrosis of hepatocytes.The articles have been scanned in colour with a HP Scanjet 5590; 600dpi. Adobe Acrobat XI Pro was used to OCR the text and also for the merging and conversion to the final presentation PDF-format.mn201

    Patients’ perceptions on non‐specific effects of acupuncture: Qualitative comparison between responders and non‐responders

    Get PDF
    Background: Non-specific effect of acupuncture constitutes part of the overall effect generated via clinical encounter beyond needle insertion and stimulation. It is unclear how responders and non-responders of acupuncture experience non-specific effects differently. We aimed to compare their experiences in a nested qualitative study embedded in an acupuncture randomized trial on functional dyspepsia. Methods: Purposive sampling was used to capture experience of responders (n=15) and non-responders (n=15) to acupuncture via individual in-depth interviews. Design and analysis followed a framework analysis approach, with reference to an existing model on acupuncture non-specific effects. Themes emerging outside of this model were purposefully explored. Results: Responders had a more trusting relationship with acupuncturist in response to their expression of empathy. In turn they were more actively engaged in lifestyle modifications and dietary advice offered by acupuncturists. Non-responders were not satisfied with the level of reassurance regarding acupuncture safety. They were also expecting more peer support from fellow participants, regarded that as an empowerment process for initiating and sustaining lifestyle changes. Conclusions: Our results highlighted key differences in acupuncture non-specific effect components experienced by responders and non-responders. Positive non-specific effects contributing to overall benefits could be enhanced by emphasizing on empathy expression from acupuncturists, trust-building, offering appropriate explanations on safety, and organizing patient support groups. Further research on the relative importance of each component is warranted

    Asymmetric Bethe-Salpeter equation for pairing and condensation

    Full text link
    The Martin-Schwinger hierarchy of correlations are reexamined and the three-particle correlations are investigated under various partial summations. Besides the known approximations of screened, ladder and maximally crossed diagrams the pair-pair correlations are considered. It is shown that the recently proposed asymmetric Bethe-Salpeter equation to avoid unphysical repeated collisions is derived as a result of the hierarchical dependencies of correlations. Exceeding the parquet approximation we show that an asymmetry appears in the selfconsistent propagators. This form is superior over the symmetric selfconsistent one since it provides the Nambu-Gorkov equations and gap equation for fermions and the Beliaev equations for bosons while from the symmetric form no gap equation results. The selfenergy diagrams which account for the subtraction of unphysical repeated collisions are derived from the pair-pair correlation in the three-particle Greenfunction. It is suggested to distinguish between two types of selfconsistency, the channel-dressed propagators and the completely dressed propagators, with the help of which the asymmetric expansion completes the Ward identity and is Ί\Phi-derivable.Comment: 12 pages. 26 figure

    All-optical switching and strong coupling using tunable whispering-gallery-mode microresonators

    Full text link
    We review our recent work on tunable, ultrahigh quality factor whispering-gallery-mode bottle microresonators and highlight their applications in nonlinear optics and in quantum optics experiments. Our resonators combine ultra-high quality factors of up to Q = 3.6 \times 10^8, a small mode volume, and near-lossless fiber coupling, with a simple and customizable mode structure enabling full tunability. We study, theoretically and experimentally, nonlinear all-optical switching via the Kerr effect when the resonator is operated in an add-drop configuration. This allows us to optically route a single-wavelength cw optical signal between two fiber ports with high efficiency. Finally, we report on progress towards strong coupling of single rubidium atoms to an ultra-high Q mode of an actively stabilized bottle microresonator.Comment: 20 pages, 24 figures. Accepted for publication in Applied Physics B. Changes according to referee suggestions: minor corrections to some figures and captions, clarification of some points in the text, added references, added new paragraph with results on atom-resonator interactio

    Association of global coagulation profiles with cardiovascular risk factors and atherosclerosis: A sex disaggregated analysis from the BioHEART-CT study

    Get PDF
    Background: Although the association between dysregulated coagulation and atherosclerosis is well recognized, individual assays have been of minimal value in understanding disease susceptibility. Here we investigated the association of global coagulation profiles with coronary artery disease with consideration of sex differences. Methods and Results: The study included patients from the BioHEART-CT (The BioHEART Study: Assessing Patients With Suspected Cardiovascular Disease for New Disease Markers and Risk Factors) biobank who had computed tomography coronary angiograms scored for coronary artery calcium score (CACS) and Gensini score. The cohort included 206 adult patients who were referred for clinically indicated computed tomography coronary angiography and had a median of 2 major cardiac risk factors; 50% were women and the average age was 62.6 years (±9.9 years). The overall hemostatic potential (OHP) and calibrated automated thrombography generation assays were performed on platelet-poor plasma. CACS and Gensini score in men were significantly correlated in bivariate analysis with measures from the OHP assay, and regression models predicting disease severity by CACS or Gensini score were improved by adding the OHP assay variables in men but not in women. The calibrated automated thrombography generation assay demonstrated a more hypercoagulable profile in women than in men. The OHP assay showed hypercoagulable profiles in women with hyperlipidemia and men with obesity. Conclusions: The OHP assay identified hypercoagulable profiles associated with different risk factors for each sex and was associated with CACS and Gensini score severity in men, emphasizing the associations between increased fibrin generation and reduced fibrinolysis with cardiac risk factors and early atherosclerosis. Registration Information: www.anzctr.org.au. Identifier: ACTRN12618001322224.Katharine A. Kott, Marie-Christine Morel-Kopp, Stephen T. Vernon, Yuki Takagi, Belinda A. Di Bartolo, Karlheinz Peter, Jean Y. Yang, Stuart M. Grieve, Christopher Ward, Gemma A. Figtre
    • 

    corecore