38 research outputs found

    Measurement of forward charged hadron flow harmonics in peripheral PbPb collisions at √sNN = 5.02 TeV with the LHCb detector

    Get PDF
    Flow harmonic coefficients, v n , which are the key to studying the hydrodynamics of the quark-gluon plasma (QGP) created in heavy-ion collisions, have been measured in various collision systems and kinematic regions and using various particle species. The study of flow harmonics in a wide pseudorapidity range is particularly valuable to understand the temperature dependence of the shear viscosity to entropy density ratio of the QGP. This paper presents the first LHCb results of the second- and the third-order flow harmonic coefficients of charged hadrons as a function of transverse momentum in the forward region, corresponding to pseudorapidities between 2.0 and 4.9, using the data collected from PbPb collisions in 2018 at a center-of-mass energy of 5.02 TeV . The coefficients measured using the two-particle angular correlation analysis method are smaller than the central-pseudorapidity measurements at ALICE and ATLAS from the same collision system but share similar features

    Helium identification with LHCb

    Get PDF
    The identification of helium nuclei at LHCb is achieved using a method based on measurements of ionisation losses in the silicon sensors and timing measurements in the Outer Tracker drift tubes. The background from photon conversions is reduced using the RICH detectors and an isolation requirement. The method is developed using pp collision data at √(s) = 13 TeV recorded by the LHCb experiment in the years 2016 to 2018, corresponding to an integrated luminosity of 5.5 fb-1. A total of around 105 helium and antihelium candidates are identified with negligible background contamination. The helium identification efficiency is estimated to be approximately 50% with a corresponding background rejection rate of up to O(10^12). These results demonstrate the feasibility of a rich programme of measurements of QCD and astrophysics interest involving light nuclei

    Curvature-bias corrections using a pseudomass method

    Get PDF
    Momentum measurements for very high momentum charged particles, such as muons from electroweak vector boson decays, are particularly susceptible to charge-dependent curvature biases that arise from misalignments of tracking detectors. Low momentum charged particles used in alignment procedures have limited sensitivity to coherent displacements of such detectors, and therefore are unable to fully constrain these misalignments to the precision necessary for studies of electroweak physics. Additional approaches are therefore required to understand and correct for these effects. In this paper the curvature biases present at the LHCb detector are studied using the pseudomass method in proton-proton collision data recorded at centre of mass energy √(s)=13 TeV during 2016, 2017 and 2018. The biases are determined using Z→μ + μ - decays in intervals defined by the data-taking period, magnet polarity and muon direction. Correcting for these biases, which are typically at the 10-4 GeV-1 level, improves the Z→μ + μ - mass resolution by roughly 18% and eliminates several pathological trends in the kinematic-dependence of the mean dimuon invariant mass

    Study of CP violation in B0 → DK⋆(892)0 decays with D → Kπ(ππ), ππ(ππ), and KK final states

    Get PDF
    A measurement of CP-violating observables associated with the interference of B0 → D0K⋆ (892)0 and B0 → D¯ 0K⋆ (892)0 decay amplitudes is performed in the D0 → K∓π ±(π +π −), D0 → π +π −(π +π −), and D0 → K+K− fnal states using data collected by the LHCb experiment corresponding to an integrated luminosity of 9 fb−1 . CP-violating observables related to the interference of B0 s → D0K¯ ⋆ (892)0 and B0 s → D¯ 0K¯ ⋆ (892)0 are also measured, but no evidence for interference is found. The B0 observables are used to constrain the parameter space of the CKM angle γ and the hadronic parameters r DK⋆ B0 and δ DK⋆ B0 with inputs from other measurements. In a combined analysis, these measurements allow for four solutions in the parameter space, only one of which is consistent with the world average

    High-resolution electrical resistivity tomography monitoring of a tracer test in a confined aquifer

    Get PDF
    A permanent geoelectrical subsurface imaging system has been installed at a contaminated land site to monitor changes in groundwater quality after the completion of a remediation programme. Since the resistivities of earth materials are sensitive to the presence of contaminants and their break-down products, 4-dimensional resistivity imaging can act as a surrogate monitoring technology for tracking and visualising changes in contaminant concentrations at much higher spatial and temporal resolution than manual intrusive investigations. The test site, a municipal car-park built on a former gas-works, had been polluted by a range of polycyclic aromatic hydrocarbons and dissolved phase contaminants. It was designated statutory contaminated land under Part IIA of the UK Environmental Protection Act due to the risk of polluting an underlying minor aquifer. Resistivity monitoring zones were established on the boundaries of the site by installing vertical electrode arrays in purpose-drilled boreholes. After a year of monitoring data had been collected, a tracer test was performed to investigate groundwater flow velocity and to demonstrate rapid volumetric monitoring of natural attenuation processes. A saline tracer was injected into the confined aquifer, and its motion and evolution were visualised directly in high-resolution tomographic images in near real-time. Breakthrough curves were calculated from independent resistivity measurements, and the estimated seepage velocities from the monitoring images and the breakthrough curves were found to be in good agreement with each other and with estimates based on the piezometric gradient and assumed material parameters

    4D geoelectrical monitoring of natural attenuation processes at a contaminated former gas-works site [extended abstract]

    Get PDF
    A permanent automated geoelectrical imaging system was installed at a contaminated land site to monitor resistivity changes associated with groundwater quality after the completion of a remediation programme. The former gasworks site had been designated statutory contaminated land due to the risks of pollution of an underlying minor aquifer. The system collected data at regular scheduled intervals from a network of electrodes arranged in vertical borehole arrays on the boundaries of the site. The incoming data from the system were automatically inverted to produce 4D resistivity images. Analysis was carried out over one year, revealing resistivity fluctuations in the infilled ground beneath the tarmac that were strongly temperature dependent. But in the underlying sand and gravel aquifer there was a steady increase in resistivity that was suggestive of a reduction in groundwater contamination after the removal of the contaminant source zones. A tracer test was also undertaken to investigate the groundwater flow velocity and demonstrate rapid 4D geoelectrical monitoring of natural attenuation processes. The motion and evolution of the tracer were visualised directly in high-resolution volumetric images in near realtime. Seepage velocities measured from the images agreed closely with estimates based on the piezometric gradient and assumed material parameters

    Geophysical anatomy of the Hollin Hill landslide, North Yorkshire, UK.

    Get PDF
    Geophysical methods are playing an increasingly important role in the investigation and monitoring of landslides (e.g. Jongmans and Garambois, 2007); such methods are proving to be particularly effective for revealing the 3D structure, failure surfaces, and the hydrogeological regimes associated with rock and earth slides. In this paper we present the results of a geoelectrical reconnaissance survey of the Hollin Hill landslide, UK. This work was undertaken in advance of the installation of a permanent geophysical and geotechnical monitoring system, and was designed to assess the suitability of resistivity and self-potential (SP) methods for investigating and monitoring this site. In particular, we were concerned to assess the electrical property contrasts and the magnitude of SP response across the study area

    Autism spectrum disorder in children born preterm—role of exposure to perinatal inflammation

    Get PDF
    Autism Spectrum Disorder (ASD) is the collective term for neurodevelopmental disorders characterized by qualitative impairments in social interaction, communication, and a restricted range of activities and interests. Many countries, including Australia, have reported a dramatic increase in the number of diagnoses over the past three decades, with current prevalence of ASD at 1 in every 110 individuals (~1%). The potential role for an immune-mediated mechanism in ASD has been implicated by several studies, and some evidence suggests a potential link between prenatal infection-driven inflammation and subsequent development of ASD. Furthermore, a modest number of contemporary studies have reported a markedly increased prevalence of ASD in children born preterm, who are at highest risk of exposure to perinatal inflammation. However, the mechanisms that underpin the susceptibility to infection-driven inflammation during pregnancy and risk of preterm birth, and how these intersect with the subsequent development of ASD in the offspring, is not understood. This review aims to summarize and discuss the potential mechanisms and evidence for the role of prenatal infection on the central nervous system, and how it may increase the susceptibility for ASD pathogenesis in children born preterm
    corecore