34 research outputs found

    Immunohistochemical evaluation of p53 expression in lung cancer of patients with paraneoplastic rheumatic syndrome

    No full text
    Aim: To study p53 expression in the tumor tissue of lung cancer (LC) patients with paraneoplastic rheumatic syndrome (PNRS). Materials and Methods: There have been used either biopsy or surgically resected tumor samples of 140 LC patients (83 patients without PNRS, 57 patients with PNRS). For evaluation of p53 expression in LC samples, immunohistochemical analysis was performed. Results: It has been shown that p53 expression in tumor samples from LC patients with PNRS was significantly higher compared to that in LC patients without PNRS. It has been shown that p53 expression is more frequently registered in patients with lung adenocarcinoma with PNRS than in patients with lung adenocarcinoma without this syndrome. Conclusion: The presence of PNRS in LC patients with p53 expression is associated with higher aggressiveness of tumor

    Electric field study with HIBP in OH and ECRH plasmas on the T-10 tokamak

    No full text
    The plasma potential φ and radial electric field Er were studied on T-10 in a wide range of ohmic and ECRH regimes. At densities ne> 10¹⁹ m⁻³, the potential has negative sign over the whole plasma cross section. At lower densities, the outer zone with positive φ and Er is formed. The absolute value of potential at mid-radius grows with density up to ne ≈ 3×10¹⁹ m⁻³ and then saturates. In regimes with ECR heating, |φ| decreases owing to the density pump-out and the electron temperature increase. Measurements of Er are compared with numerical simulations with several codes including nonambipolar fluxes due to the toroidal field ripple. The change of radially averaged ¬Er with density and temperature qualitatively agrees with neoclassical expectations.Потенциал плазмы φ и радиальное электрическое поле Er исследовались на токамаке T-10 в широком диапазоне омических и ЭЦР-режимов. При плотностях ne> 10¹⁹ м⁻³ потенциал имеет положительный знак во всем сечении плазмы. При меньших плотностях во внешней зоне потенциал и Er меняют знак. Абсолютное значение потенциала на середине радиуса растет с плотностью вплоть до ne ≈ 3×10¹⁹ м⁻³, а затем насыщается. В режимах с ЭЦР-нагревом абсолютная величина |φ| уменьшается за счет откачки плотности и роста электронной температуры. Измерения Er сравнивались с численными расчетами по нескольким кодам, учитывающим неамбиполярные потоки за счет гофрировки тороидального поля. Изменение среднего поля ¬Er с плотностью и температурой не противоречит неоклассическим ожиданиям.Потенціал плазми φ та радіальне електричне поле Er було досліджено на токамаці Т-10 у широкому діапазоні омічних та ЕЦР-режимів. При щiльностях ne> 10¹⁹ м⁻³ потенцiал має позитивний знак в усьому перетинi плазми. При менших щiльностях у зовнiшнiй зонi потенціал та Er змiнюють знак. Абсолютне значення потенцiалу на серединi радіуса росте зi щiльністью майже до ne ≈ 3×10¹⁹ м⁻³, а потiм насичується. У режимах з ЕЦР-нагрiвом абсолютна величина |φ|зменшується за рахунок відкачки щiльностi та росту електронноï температури. Вимiрювання Er порiвнювалися з числовими розрахунками за декiлькома кодами, які враховують неамбіполярнi потоки за рахунок гофрировки тороïдального поля. Зміна середнього поля ¬Er з щiльнiстю та температурою не протирiчить неокласичним сподiванням

    Study of plasma potential, its fluctuations and turbulence rotation in the T-10 tokamak

    Get PDF
    Plasma potential, its oscillations and turbulence rotation were studied on T-10 in a wide range of ohmic and ECRH regimes. The potential has negative sign over the whole plasma cross section. Broadband turbulence tends to rotate with E×B drift velocity. Rotation and potential evolve together with plasma confinement. Frequency of potential oscillations in the range of geodesic acoustic modes does not change with radius that disagrees with theoretical predictions.Потенциал плазмы, его колебания и вращение исследовались на токамаке T-10 в широком диапазоне омических и ЭЦР-режимов. Потенциал – отрицательный по всему сечению плазмы. Вращение турбулентности соответствует вращению за счет (E×B)-дрейфа. Вращение и потенциал чувствительны к изменениям удержания. Частота колебаний потенциала в диапазоне геодезических акустических мод не меняется по радиусу, что не соответствует локальной теории ГАМ.Потенціал плазми, його коливання та обертання було досліджено на токамаці Т-10 у широкому діапазоні омічних та ЕЦР-режимів. Потенціал має негативну величину по всьому перетину плазми. Обертання турбуленції відповідає обертанню за рахунок (E×B)-дрейфу. Обертання і потенціал чутливі до зміни утримання. Частота коливань потенціалу у діапазоні геодезичних акустичних мод ні змінюється в залежності від радіусу, що не відповідає локальній теорії ГАМ

    New precision measurement of the J/ψJ/\psi- and ψ\psi' -meson masses

    Full text link
    A new high precision measurement of the J/ψJ/\psi- and ψ\psi'-meson masses has been performed at the VEPP-4M collider using the KEDR detector. The resonant depolarization method has been employed for the absolute calibration of the beam energy. The following mass values have been obtained: MJ/ψ=3096.917±0.010±0.007M_{J/\psi} = 3096.917 \pm 0.010 \pm 0.007 MeV, Mψ=3686.111±0.025±0.009M_{\psi'} = 3686.111 \pm 0.025 \pm 0.009 MeV. The relative measurement accuracy has reached 4.1064. 10^{-6} for J/ψJ/\psi and 7.1067. 10^{-6} for ψ\psi', approximately 3 times better than in the previous precise experiments.Comment: 12 pages, 4 tables, 10 figure

    Role of turbulence and electric fields in the establishment of improved confinement in tokamak plasmas

    No full text
    An extensive (INTAS) research programme started in 2002 to investigate the correlations between on the one hand the occurrence of transport barriers and improved confinement in the medium-size tokamaks TEXTOR and T-10 and on the smaller tokamaks FT-2, TUMAN-3M and CASTOR, and on the other hand electric fields, modified magnetic shear and electrostatic and magnetic turbulence using advanced diagnostics with high spatial and temporal resolution and of various active means to externally control plasma transport . This has been done in a strongly coordinated way and exploiting the complementarity of TEXTOR and T-10 and the backup potential of the three other tokamaks, which together have all the relevant experimental tools and theoretical expertise

    Застосування кремнієвої структури з глибоким бар'єром для виявлення солей хлорної кислоти

    No full text
    У роботі розглянуто можливість виявлення солей соляної кислоти за допомогою кремнієвих сенсорних структур з фотоелектричним принципом перетворення. Запропоновані структури реалізують принцип перетворення, що відрізняється від принципу, який застосовано у відомих структурах типу LAPS (потенціометричний сенсор із світловою адресацією). Основою таких пристроїв є "глибока" кремнієва бар'єрна структура. У запропонованій схемі сигналом датчика є фотострум через бар'єрну структуру, індукований світлом із області сильного поглинання кремнію. Це дозволяє отримувати максимальні зміни фотоструму внаслідок зміни швидкості рекомбінації на робочій поверхні. Слід зазначити, що запропонована структура дозволяє більш просту технічну реалізацію, ніж структури LAPS. Експериментально досліджено декілька аналітів (хлоридів), які містять метали з різною відносною електронегативністю (Fe, Zn та Al). Експериментально показано, що залежність фотоструму від напруги поляризації (напруга, яка змінює приповерхневий вигин зон) є інформативною для виявлення таких аналітів. В рамках моделі Стівенсона-Кейса отримані результати можна пояснити якісно. Основною причиною, яка дозволяє виявлення таких аналітів, є вплив локального електростатичного поля адсорбованих іонів на параметри рекомбінації поверхні кремнію.The possibility of the detection of hydrochloric acid salts by silicon sensory structures with photovoltaic principle of transformation has been considered in this work. The proposed structures realize transducer principle that differs from the well-known conventional LAPS (light-addressable potentiometric sensors). The basis of such devices is a "deep" barrier silicon structure. In the proposed scheme, the sensor signal is the photocurrent through the barrier structure induced by light in the range of high absorption. It allows receiving maximum changes of photocurrent due to changes of recombination rate on working surface. It should be noted that the proposed structure allows simpler technical realization than conventional LAPS. Several analytes (chlorides), containing different metals with various relative electronegativity (Fe, Zn and Al), were experimentally investigated. It has been experimentally shown that dependences of photocurrent on polarization voltage (the voltage that changes the surface band bending) is very informative for the detection of such analytes. Within the framework of the Stevenson-Keyes model, the obtained results can be explained qualitatively. The principal reason allowing the detection is the influence of the local electrostatic field of adsorbed ions on the recombination parameters of the silicon surface

    Optical biosensors based on the surface plasmon resonance phenomenon: optimization of the metal layer parameters

    No full text
    Application of the evanescent wave phenomena (e.g. surface plasmon resonance) in the chemical and biochemical sensors provides both optimal conditions for registration of specific interactions and high sensitivity. At the same time, the stability and reproducibility of parameters of a thin gold film (where the plasmon oscillations occur) are key problems for both (i) optimal transformation of biochemical information into the signal that is convenient for further treatment and (ii) the formation of artificial interfacial architectures. The paper presents results concerning the study of the deposition process temperature regimes influence on optical properties and structure of thin gold films. Morphological and topographic features of the thin film structures were analyzed using X-ray diffraction and atomic force microscopy, respectively. It is shown that the simple procedure of the low temperature annealing (at ~ 120°C) provides optimum parameters of thin gold films in view of their application as physical transducers in optical biosensors. Finally, the SPR transducer was fabricated with high sensitive elements used in the device «PLASMON-4M» elaborated in the Institute of Semiconductor Physics (NAS of Ukraine)
    corecore