215 research outputs found

    EP-DRAFT-1.1 2014-01-19 OSI-GAM-SOP-00x In Situ High-resolution Gamma Spectroscopy

    Full text link
    Abstract not provide

    Contaminants in Unionid Mussels from the Confluence of the Mississippi and Illinois Rivers

    Get PDF
    Unionid mussels were collected from three mussel beds near the confluence of the Mississippi and Illinois rivers in 2003 to evaluate concentrations of selected elements and organic compounds in three abundant species and to preliminarily investigate the relative contribution of these waterways to observed contaminant burdens. Copper (Cu), selenium (Se), and zinc (Zn) concentrations were higher and lead (Pb) concentrations were lower in Amblema plicata collected downstream of the confluence than in those collected upstream. Mean concentrations of nickel (Ni), total mercury (Hg), methylmercury (MeHg), Pb, and Zn varied by species. Concentrations of cadmium (Cd) decreased with age in A. plicata from two of three sites. Tissue concentrations of some elements, e.g., arsenic (As), Cd, Cu, Pb, Se, and Zn, were similar to or higher than those previously reported for unionid mussels from areas of contaminated sediment. Concentrations of Cd, Cu, and Zn in A. plicata were comparable to those collected from the Mississippi River approximately 450 and 900 km upstream from our study sites (Naimo et al. 1992). Although total Hg concentrations we observed were an order of magnitude lower than in that study, MeHg concentrations were above those associated with reductions in soft tissue mass in a study of Elliptio complanata (Salazar et al. 1995). A number of polychlorinated biphenyl (PCB) congeners were detected in A. plicata tissues, with 85% of detections occurring in mussels from downstream of the confluence. Concentrations of individual PCB congeners were ???33 ng/g ww and the maximum summed PCB congener concentration was 100.2 ng/g ww. Although few persistent pesticides were detected, -hexachlorocyclohexane (HCH) was detected in each of the species collected from below the confluence of the two rivers, and in A. plicata collected above it on both the Mississippi and Illinois rivers, at a maximum concentration of 103.5 ng/g ww. Aldrin, ??-HCH and dichlorodiphenyltrichloroethane (DDT) were detected in few of the specimens collected. The findings of this preliminary investigation suggest that unionid mussels from near the confluence of the Mississippi and Illinois rivers may be at risk of negative health effects of elevated exposure to certain environmental contaminants. Studies examining the health and productivity of unionid mussels from this area appear warranted.published or submitted for publicationis peer reviewe

    The Wiener maximum quadratic assignment problem

    Full text link
    We investigate a special case of the maximum quadratic assignment problem where one matrix is a product matrix and the other matrix is the distance matrix of a one-dimensional point set. We show that this special case, which we call the Wiener maximum quadratic assignment problem, is NP-hard in the ordinary sense and solvable in pseudo-polynomial time. Our approach also yields a polynomial time solution for the following problem from chemical graph theory: Find a tree that maximizes the Wiener index among all trees with a prescribed degree sequence. This settles an open problem from the literature.Comment: 11 pages, no figure

    Delivery actuator for a transcervical sterilization device

    Get PDF
    The use of delivery systems in the human body for positioning and deploying implants, such as closure devices, dilation balloons, stents, coils and sterilization devices, are gaining more importance to preclude surgical incisions and general anesthesia. The majorities of the non-surgical medical devices are delivered in a low profile into human body form and subsequently require specialized operations for their deployment and release. An analogous procedure for permanent female sterilization is the transcervical approach that does not require either general anesthesia or surgical incision and uses a normal body passage. The objective of this paper is to detail the design, development and verification of an ergonomic actuator for a medical application. In particular, this actuator is designed for the deployment and release of an implant to achieve instant permanent female sterilization via the transcervical approach. This implant is deployed under hysteroscopic visualization and requires a sequence of rotary and linear operations for its deployment and release. More specifically, this manually operated actuator is a hand held device designed to transmit the required forces in a particular sequence to effect both implant deployment and release at a target location. In order to design the actuator and to investigate its mechanical behavior, a three-dimensional (3D) Computer Aided Design (CAD) model was developed and Finite Element Method (FEM) was used for simulations and optimization. Actuator validation was performed following a number of successful bench-top in-air deployments and in-vitro deployments in animal tissue and explanted human uteri. During these deployments it was observed that the actuator applied the required forces to the implant resulting in successful deployment. Initial results suggest that this actuator can be used single handedly during the deployment phase. The ongoing enhancement of this actuator is moving towards ā€œfirst-in- manā€ clinical trials

    Depth-first-search and dynamic programming algorithms for efficient CMOS cell generation

    Full text link
    • ā€¦
    corecore