414 research outputs found

    Unconventional high-energy-state contribution to the Cooper pairing in under-doped copper-oxide superconductor HgBa2_2Ca2_2Cu3_3O8+δ_{8+\delta}

    Full text link
    We study the temperature-dependent electronic B1g Raman response of a slightly under-doped single crystal HgBa2_2Ca2_2Cu3_3O8+δ_{8+\delta} with a superconducting critical temperature Tc=122 K. Our main finding is that the superconducting pair-breaking peak is associated with a dip on its higher-energy side, disappearing together at Tc. This result hints at an unconventional pairing mechanism, whereas spectral weight lost in the dip is transferred to the pair-breaking peak at lower energies. This conclusion is supported by cellular dynamical mean-field theory on the Hubbard model, which is able to reproduce all the main features of the B1g Raman response and explain the peak-dip behavior in terms of a nontrivial relationship between the superconducting and the pseudo gaps.Comment: 7 pages 4 figure

    Measurement and Control of the Beam Energy for the SPIRAL2 Accelerator

    Get PDF
    WEPF32, http://accelconf.web.cern.ch/AccelConf/ibic2013/International audienceThe first part of the SPIRAL2 facility, which entered last year in the construction phase at GANIL in France, will be composed of an ion source, a deuteron/proton source, a RFQ and a superconducting linear accelerator delivering high intensities, up to 5 mA and 40MeV for the deuteron beams. As part of theMEBT commissioning, the beam energy will be measured on the BTI (Bench of Intermediate Test) at the exit of the RFQ. At the exit of the LINAC, the system has to measure but also control the beam energy. The control consists in ensuring that the beam energy is under a limit by taking account of the measurement uncertainty. The energy is measured by a method of time of flight, the signal is captured by non-intercepting capacitive pick-ups. This paper presents also the results obtained in terms of uncertainties and dynamics of measures

    Beam Intensity and Energy Control for the SPIRAL2 Facility

    Get PDF
    TUPB029 - ISBN 878-3-95450-122-9International audienceThe first part of the SPIRAL2 facility, which entered last year in the construction phase at GANIL in France, consists of an ion source, a deuteron and a proton source, a RFQ and a superconducting linear accelerator delivering high intensities, up to 5 mA and 40 MeV for the deuteron beams. Diagnostic developments have been done to control both beam intensity and energy by non-interceptive methods at the linac exit. The beam current is measured by using couples of ACCT-DCCT installed along the lines and the beam energy by using a time of flight device. This paper gives explanations about the technical solutions, the results and resolutions for measuring and controlling the beam

    Progress on the Beam Energy Monitor for the SPIRAL2 Accelerator.

    Get PDF
    WEPF29, posterInternational audienceThe first part of the SPIRAL2 project entered last year in the end of the construction phase at GANIL in France. The facility will be composed by an ion source, a deuteron/proton source, a RFQ and a superconducting linear accelerator. The driver is planned to accelerate high intensities, up to 5 mA and 40 MeV for the deuteron beams. A monitoring system was built to measure the beam energy on the BTI line (Bench of Intermediate Test) at the exit of the RFQ. As part of theMEBT commissioning, the beamenergy will be measured on the BTI with an Epics monitoring application. At the exit of the LINAC, another system will have to measure and control the beam energy. The control consists in ensuring that the beam energy stays under a limit by taking account of the measurement uncertainty. The energy is measured by a method of time of flight; the signal is captured by non-intercepting capacitive pick-ups. This paper describes the BTI monitor interface and presents the system evolution following the design review

    Reduced Chlorine in Drinking Water Distribution Systems Impacts Bacterial Biodiversity in Biofilms.

    Get PDF
    In drinking water distribution systems (DWDS), a disinfectant residual is usually applied to limit bacterial regrowth. However, delivering water with no or reduced chlorine residual could potentially decrease the selection for antimicrobial resistant microorganisms, favor bacterial regrowth and result in changes in bacterial populations. To evaluate the feasibility of water reduction in local DWDS while ensuring water safety, water quality was measured over 2 months in two different networks, each of them harboring sub-areas with normal and reduced chlorine. Water quality remained good in chlorine reduced samples, with limited development of total flora and absence of coliforms. Furthermore, 16S rRNA amplicon-based metagenomics was used to investigate the diversity and the composition of microbial communities in the sub-networks. Taxonomic classification of sequence reads showed a reduced bacterial diversity in sampling points with higher chlorine residuals. Chlorine disinfection created more homogeneous bacterial population, dominated by <i>Pseudomonas</i> , a genus that contains some major opportunistic pathogens such as <i>P. aeruginosa</i> . In the absence of chlorine, a larger and unknown biodiversity was unveiled, also highlighted by a decreased rate of taxonomic classification to the genus and species level. Overall, this experiment in a functional DWDS will facilitate the move toward potable water delivery systems without residual disinfectants and will improve water taste for consumers

    Measure Twice: Promise of Liquid Biopsy in Pediatric High-Grade Gliomas

    Get PDF
    Purpose To review and critique the current state of liquid biopsy in pHGG. Materials and Methods Published literature was reviewed for articles related to liquid biopsy in pediatric glioma and adult glioma with a focus on high-grade gliomas. Results This review discusses the current state of liquid biomarkers of pHGG and their potential applications for liquid biopsy development. Conclusions While nascent, the progress toward identifying circulating analytes of pHGG primes the field of neuro-oncoogy for liquid biopsy development
    corecore